There is no price at present, you can Request a Quote
Type | Semi-Hermetic Compressors |
Body Type | 4D Compressor |
Compressor Cooling | Discus |
Phase | Three Phase |
Electrical | 575-3 |
Frequency | 60Hz |
Copeland Compressor 4DJ3R28ME-TSE-200
There is no price at present, you can Request a Quote
People who bought this item also viewed
Mitsubishi Compressor RB247YFY
Tecumseh Compressor TRK5480Y
Toshiba Compressor DA422A3F-28ZAD
Tecumseh Compressor TRK5518C
Copeland Compressor CR24KQ-TF5-240AA
Copeland Compressor ZR72KCE-TFD-422
Copeland Compressor ZRD72KCE-TFD-433
Copeland Compressor ZF15K4E-TF5-550
Hitachi Compressor ASH280DG-C8DU
Sanyo Compressor C-SCP400H38B
Tecumseh Compressor AE4470E-FZ3C
Hitachi Compressor SH310UV-C8DU
TRIAD Transformer CST25-0200
Danfoss Expansion Valve 068F4081
Siemens Contactor 3RT2016-2AK64-3MA0
Sanyo Denki Fan 109S030
ZHONGDA Electric Motor Z5D250-24A1
ENTEGRIS Filter YY260103N
Danfoss Sight Glass SGN22S
Tecate Capacitor 630V0.047UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ARK Air Cylinder KCDQ2B50-30D
Becker Vacuum Pump DT4.25
KOGANEI Air Cylinder TBDA20X150-1W
Baumer Encoder GBMMW.B20EPA2
Recent related posts
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser
-
10/18/2023
Dehumidifier Compressor Hot: Reasons and Fixes
A dehumidifier is an essential appliance for maintaining a comfortable and healthy indoor environment by reducing excessive humidity.
-
07/15/2020
ZP49KSE-TF74.1 horsepower 60Hz (R410A) air conditioner Emerson Copeland compressor
Today I want to introduce the Emerson Copeland compressor ZP49KSE-TF7, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioner. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 4.1 hp. Other technical parameters can be downloaded from our company's website to download the product manual.
-
07/17/2020
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit A central air-conditioning system in a public area uses a screw chiller. During operation, a copper tube in the evaporator leaks due to a malfunction. After further inspection by the technical staff, it was confirmed that the fault was leakage of the copper pipe of the evaporator of the chiller.
-
08/08/2020
Types and differences of various refrigerants
Types and differences of various refrigerants 1. R22 is widely used in my country. Some experts believe that if R123 can finally be lifted, then the day when R22 is lifted will not be far away.
-
08/07/2020
What should I do if there is water in the refrigerator compartment
In our daily life, many household appliances are used very frequently, but when encountering some emergencies, they feel helpless and have to ask after-sales or repair personnel for help.
-
09/22/2020
Discussion on Calculation Method of Surge Line of Rich Gas Compressor
1 Introduction The catalytic cracking rich gas compressor is a kind of compressor, which is very representative. For this reason, the catalytic cracking rich gas compressor is taken as an example to discuss the calculation method of the surge line of the rich gas compressor control system.
-
08/14/2020
How does the cold storage refrigeration system supplement and discharge refrigerant
The cold storage refrigeration system must ensure that the refrigerant is dry when adding refrigerant (only applicable to fluorine refrigerant refrigeration systems),
-
08/15/2020
The correct operation method of air-cooled refrigerator
For companies that use air-cooled refrigerators, the stable use of equipment is the most important thing, and if you don’t pay much attention during use, it will cause problems with the stability of the equipment due to some external factors.
-
09/07/2020
Why is air humid after compression
We all know the importance of compressed air drying. This is a critical step in the compressed air process. If you skip this step, it may cause a large amount of water to accumulate in your system. So why does compressed air get wet?