Series | L Series |
Type | Light Commercial Refrigeration Compressors |
Refrigerant | R290 |
Segment usage | Refrigeration LT |
Voltage | 220 V |
Phase | 1 Ph |
Frequency | 50 Hz |
Weight | 10.3 kg |
Danfoss Compressor NLY60LAa
People who bought this item also viewed
Mitsubishi Compressor RB247YFY
Sanyo Compressor C-2RN153H3A
Mitsubishi Compressor TNB220FMCH
Copeland Compressor ZB38KCE-TFD-265
Danfoss Compressor MTZ72HN4AVE
Danfoss Compressor 104G8501
Danfoss Compressor MTZ19JA3VE
Danfoss Compressor MT81HP4AVE
Toshiba Compressor PH330X2CS-8KU3
GMCC Compressor YH480X3CS-4MUC1
GMCC Compressor PH215M2C-4FT
TRIAD Transformer VPP24-420
Danfoss Expansion Valve 068F5029
LG LS Contactor MC-150A
Sanyo Denki Fan 9G1212G1021
Donaldson Filter P164164
Danfoss Sight Glass SGR 014-0006
DAIKIN Expansion Valve Coil RXR150RC
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
BANDO Belt STS S3M-825-10
Sanyo Denki Fan 9CRB0412P5S208
JSCC Speed Reducer 90GK36RT
KOGANEI Air Cylinder TBDAM20X40
Recent related posts
-
03/03/2021
Type selection calculation of servo motor
Confirmation of speed and encoder resolution. Conversion of load torque on motor shaft and calculation of acceleration and deceleration torque.
-
06/25/2020
What refrigerator is used for cooling
Most of them use fluorine-free refrigerants, and the models include R600A, R410A, R407A, R134A, etc., which are all green and environmentally friendly. The specific models are marked on the nameplate on the rear side of the refrigerator. the way.
-
06/21/2020
Common faults and maintenance of air compressor
Common faults and maintenance of air compressor <img src="{{media url="Common_faults_and_maintenance_of_air_compressor.jpg"}}" alt="" /> Common faults and maintenance of air compressor Air compressors are widely used in various industries with the development of technology, but no matter what type of air compressor, there will be some problems in the process of use. The following editors will now introduce some common faults and maintenance methods, let's take a look.
-
08/05/2020
How to solve the common old problems in the operation of chillers
In the pharmaceutical, food, chemical and other industries, process water cooling is required. The chiller has become a must-choice equipment for many industries.
-
06/14/2020
York NGC200 Petroleum Coal Chemical Screw Refrigeration Compressor Oil Temperature Excessive Failure Overhaul
York NGC200 Petroleum Coal Chemical Screw Refrigeration Compressor Oil Temperature Excessive Failure Overhaul York NGC200 Petroleum Coal Chemical Screw Refrigeration Compressor Oil Temperature Excessive Failure Overhaul, Oil Temperature Excessive Failure ﰸ2 䀀 ᅵ皥
-
07/23/2020
Do you know the causes, hazards, treatment and prevention methods of compressor liquid strike?
Liquid hammer refers to the situation in which the refrigerant liquid or wet vapor is sucked into the compressor by the compressor due to the failure or insufficient heat absorption and evaporation of the refrigerant, which is called liquid hammer.<br></br> <br></br>
-
08/11/2020
Installation conditions and precautions of refrigeration compressors
The selection of the installation site is most ignored by the staff. Often after the compressor is purchased, you can find a location and use it immediately after piping. There is no prior planning at all.
-
04/01/2022
How to Replace Air Conditioner Fan Blade?
Air conditioner is also known as air conditioning machine. It is a machine that manually adjusts and controls the temperature, humidity, cleanliness, speed and other parameters of the ambient air in the building.
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.
-
11/09/2021
PLC (Programmable Logic Controllers) and HMI (Human-Machine Interface) for Intelligent Factory
The development of "intelligent factory" has put forward a new direction for manufacturers. It is necessary for manufacturers to master the production and marketing process clearly