Shaft diameter (max):6 mm
Resolution (max):1.024 ppr
Output frequency (max):100 kHz
Operating temperature:-20 ... +70
Enclosure rating:IP 54
Eltra Encoder EH38B1024S8/24P6X3PR
People who bought this item also viewed
HENGSTLER Encoder RI58-O/4096AK.42RB
Nemicon Encoder OEK-20-2MC
LS Mecapion Encoder H40-8-0360VL
Baumer Encoder BMMV 58K1N24R12/18CON
Fanuc Servo Motor A06B-0077-B003
Allen Bradley Servo Drive 2098-DSD-030
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Blue-White Diaphragm Pump AZ
Contrinex Sensor DW-AD-632-M12-120
Panasonic Servo Motor MQMF011L1D2
Gems Level Meter XM-66400
Delixi Fuse RT14-20 3A
Recent related posts
-
06/14/2020
Compressor common knowledge, how much do you know
Compressor common knowledge, how much do you know The compressor is the heart of the refrigeration system. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the moto 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿
-
06/22/2020
Causes and judgement of centrifugal compressor surge
Causes and judgement of centrifugal compressor surge Causes of centrifugal compressor surge ①Flow<img src="{{media url="Causes_and_judgement_of_centrifugal_compressor_surge.jpg"}}" alt="" /> Each centrifugal compressor corresponds to a curve between outlet pressure P and flow rate Q at different speeds n, as shown in Figure 2.
-
07/20/2020
Analysis of circuit diagrams of two compressors' phase failure protection
Analysis of circuit diagrams of two compressors' phase failure protection Air compressor phase failure protection circuit Protection circuit diagram Air compressor phase failure protection circuit
-
06/14/2020
What is an air-cooled heat pump Introduction of knowledge about air-cooled heat pump
What is an air-cooled heat pump Introduction of knowledge about air-cooled heat pump What is an air-cooled heat pump-Introduction to an air-cooled heat pump
-
06/20/2023
LG Refrigerator Problems: Common Issues and Solutions
LG refrigerators are known for their sleek design, advanced features, and energy efficiency. However, even the best refrigerators can experience problems from time to time.
-
09/14/2020
Application of oil-free lubrication technology in the cylinder of the high-pressure section of the piston-type nitrogen-hydrogen compressor
1. Raising the problem Compressor oil-free lubrication technology, as a new energy-saving technology, has been developed and applied to various compressors in various industries for more than 60 years.
-
03/23/2023
Common Faults, Reasons of Faults, and Solutions of Vacuum Pump
common faults like falling vacuum degree, abnormal operation, even being jammed, large noises and oil leakage resulting from not well-sealed pump body appears in the operation
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/04/2020
The difference between ordinary asynchronous motor and variable frequency motor
1. Ordinary asynchronous motors are designed according to constant frequency and constant voltage, which cannot fully meet the requirements of variable frequency speed regulation
-
06/14/2020
Characteristics of rolling rotor compressor
Characteristics of rolling rotor compressor (1) Rolling rotor rotary compressor is a commonly used compressor for room air conditioners (2) Compared with the reciprocating piston compressor, it has the following characteristics: