Max. response frequency : 35kHz
Max. allowable revolution : 3000rpm
Starting torque : Max. 40gf.cm(max. 0.00392N.m)
Resolution : 720P/R
Rotating direction : CCW
Control output : PNP open collector
Power supply : 5VDC +-5%(ripple P-P: max. 5%)
Connection type : Axial cable type
Protection structure : IP50 We can also provide the following models
E40HB12-5000-2-V-5
E58SC6-2-6-T-5-CR
E40S8-192-2-N-24
E40HB6-2000-4-V-5-C
E58SC10-300-4-T-5-C
E58SS10-600-4-N-5-CR
E58SC6-5-6-L-24-C
E58SC6-100-2-L-5-CR
E40HB6-2500-3-V-5
E58SS10-2-2-T-24
E50S8-2000-4-T-24-CS
E58SS6-192-3-N-5-CR
E58SS6-800-4-N-24-CS
E40HB12-60-4-V-5-C
E40HB8-3000-6-N-5-C
E40H10-40-4-T-24-C
E58SS10-23-4-L-5
E58SC6-250-4-L-24-CS
For more information,please contact us freely
Autonics Rotary Encoder EP58SS6-720-2R-P-5
People who bought this item also viewed
Autonics Rotary Encoder E50S8-600-6-T-24
Autonics Rotary Encoder EP50S8-64-2F-N-5
Yaskawa Servo Motor SGMGV-75ADA61
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CAMOZZI Air Cylinder 60N7L040A0075
REXROTH Overflow Valve DBDS30K1X/315
Wurth Transformer 750311567
CHINT Transformer NDKR-200
TYCO Relay V23162A 722F105
Schneider Circuit Breaker LS8F09332G
Recent related posts
-
07/16/2020
Analysis of the reason why cold storage should not be built underground
Many people think that building cold storage underground will have better thermal insulation effect than cold storage on the ground, because in the past, when the technology was backward, it was very common to choose cellars as crop storage. But from a commercial point of view, it is not scientific to blindly build the cold storage underground. The cold storage construction team stands from the perspective of consideration for customers
-
09/01/2022
Differences between a Contactor and a Relay
The contactor and the relay are all control devices used in electric circuit. But they cannot replace each other. The followings are the main differences between the two.
-
04/29/2022
How to test a contactor?
Check the rated voltage of the contactor coil and connect it to the matching power supply. Open the switch and check whether the contactor is closed. If it cannot be pulled in, it indicates that the contactor coil is faulty.
-
06/25/2020
What are the three tubes of the refrigerator compressor
What are the three tubes of the refrigerator compressor 1. The general refrigerator compressor has three pipe ports;
-
12/14/2022
What is a Memory Stick?
The memory stick is a memory cards product launched by Sony in 1999. Shaped like a chewing gum
-
08/13/2020
Adding method of refrigerant in central air conditioner
How to add refrigerant to central air-conditioning, what operating methods do you know? Let’s take a look with the editor of okmarts.com today!
-
07/16/2020
Vacuum leak test method for small cold storage equipment
Refrigeration systems with evaporating pressure gauges close to or below atmospheric pressure must be tested for vacuum leak tests, leaving the refrigeration equipment under proper vacuum for a certain period of time, reflecting and observing whether air has penetrated into the system from the reading of the vacuum pressure gauge for inspection The sealing performance of the cold storage equipment system.
-
08/02/2020
Characteristics of R12, R22, R407C refrigerants in cold storage
don’t know if you still remember that okmarts.com wrote "How to Choose Refrigerant for Cold Storage Design" some time ago. Today okmarts.com will introduce several different cold storage refrigerants in detail, namely R12, R22, R407C
-
07/01/2020
How to check the compressor body for cracks
How to check the compressor body for cracks In winter, it is relatively common for compressors to crack. I believe many people have ideas to prevent this kind of problem. In fact, it is not impossible, as long as we conduct a detailed inspection of the compressor body during normal maintenance, this problem can be avoided.
-
06/15/2020
Compressor working principle
Compressor working principle Compressor working principle Centrifugal compressor The centrifugal compressor is a working wheel with blades rotating on the shaft of the compressor. The gas entering the working wheel is carried by the blades to increa 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ࠌ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ 琉蒠S識器 直