There is no price at present, you can Request a Quote
Type: 5000
Degree Of Protection: Max.IP67
Working temperature: -40 - 85 degrees Celsius
Rotational speed: Max. 12,000 RPM
Power options: 5-30 V DC / 5 V DC / 10-30 V DC
Variants of the interface: Push-pull , RS422 (TTL), NPN OC
Resolution variants: Max. 5,000 PPR
feature: Standard, Optical
The principle of operation: Incremental
Increased resistance against vibrations and tolerance of installation errors, elimination of machine downtime and repairs thanks to sturdy bearing construction in "Safety-LockTM Design"
Suitable connection variant for every specific case: cable connection, M23, M12 and MIL connector
Reliable mounting in a wide variety of installation situations: comprehensive and proven fixing possibilities
Compatible with all US and European standards
Kuebler Encoder 8.5000.B118.0050
There is no price at present, you can Request a Quote
People who bought this item also viewed
Kuebler Encoder 8.5020.D121.1024
Kuebler Encoder 8.5020.1912.3600
LS Mecapion Encoder S48-8-2500ZT
Nemicon Encoder NOC-S5000-2MD-8-050-00E
HENGSTLER Encoder S21-2048.011
Baldor Servo Motor BSM100N-4250AA
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Allen Bradley Servo Motor 1326AB-B3E-11-K5
Panasonic Relay JQ1-B-24V-FT
JRT Air Cylinder AF30-50-PS
NEW-ERA Air Cylinder PPTS-GT6Y-5-TPQR
Parker Denison Vane Pump T6D-042-2R00-C1
Rexroth Vane Pump PVV4-1X-113
Recent related posts
-
06/23/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
07/30/2020
How important is the installation environment of the refrigeration unit Doing these 4 points is enough!
The refrigeration equipment (compressor unit) is installed in the machine room, and the surrounding environment should be maintained:<br></br>
-
06/16/2020
Compressor wiring diagram
Compressor wiring diagram Wiring diagram of single-phase compressor Although the orientation of the terminals of compressors of different manufacturers is different, they are marked with letters next to each terminal; for single-phase compressors, C 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ԫ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
06/25/2020
Why does the use of cold and air conditioning in a car increase fuel consumption because the car cannot carry a compressor
Automotive air conditioning system _ compressor power is not high Knowledge point: The principle of the "refrigeration system" of automobile air conditioners is the same as that of domestic air conditioners. Both use compressors to drive refrigerants to achieve cooling by the principle of "evaporation and heat absorption".
-
09/10/2020
Types and characteristics of air compressors and their application choices
Air compressor (English: aircompressor) is the main body of the air source device. It is a device that converts the mechanical energy of the prime mover (usually an electric motor) into gas pressure energy, and is a pressure generating device for compressed air.
-
01/07/2021
Is it normal for 1.5p air conditioner to consume 23 degrees a day
Is it normal for 1.5p air conditioner to consume 23 degrees a day You can’t believe it The 1.5P air-conditioning compressor is converted to 0.735KW/P under refrigeration conditions, and the electric power is 1.1KW, plus the fan motor of the internal and 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ծ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
05/09/2022
How to Clean Automobile Solenoid Valve?
Before removing the valve body from the bottom of the transmission, take extra care when removing the flat wire of the external solenoid valve.
-
08/24/2020
Why is it forbidden to use the refrigerator
We all know that with the continuous improvement of people’s material living standards, every household now has a refrigerator. The refrigerator is very useful in the home, especially in summer.
-
08/29/2022
4 Common Types of Circuit Breakers
The circuit breaker is an automatic device for stopping the flow of current in an electric circuit as a safety measure.
-
09/09/2020
Permanent magnet variable frequency air compressor speaks with energy saving
The permanent magnet variable frequency air compressor has been highly recognized by customers since its production. It is the leading brand of energy saving in the equipment industry. The core energy saving advantages of the equipment are as follows: