Stroke: 10 mm - 2000 mm
Piston diameter: 63 mm
Type code: CRDNG
Cushioning: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Conforms to standard: ISO 15552 (previously also VDMA 24562, ISO 6431, NF E49 003.1, UNI 10290)
Design: Piston rod: Piston
Position sensing: For proximity sensor
Symbol: 00991235
Operating pressure: 0.6 bar - 10 bar
Mode of operation: Double-acting
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 4 - Particularly high corrosion stress
For use in the food industry: See supplementary material information
Ambient temperature: -20 to 80 Celsius Degree
Cushioning length: 23 mm
Theoretical force at 6 bar, retracting: 1682 N
Theoretical force at 6 bar, advancing: 1870 N
Additional weight per 10 mm stroke: 60 g
Basic weight with 0 mm stroke: 3455 g
Type of mounting: With accessories: With internal thread: Optionally:
Pneumatic connection: G3/8
Cover material: Cast stainless steel
Seals material: TPE-U(PU)
Housing material: High-alloy stainless steel
Piston rod material: High-alloy stainless steel
Festo Air Cylinder CRDNG-63-400-PPV-A
People who bought this item also viewed
MINDMAN Air Cylinder MCRPLF-90-25-500
CKD Air Cylinder SCPG2-M-00-10-30
Festo Air Cylinder KADVBL-32-60-P-A-T2
Festo Air Cylinder CRDNG-80-450-PPV-A
Festo Air Cylinder ADNGF-16-50-P-A
Festo Air Cylinder DFM-50-100-P-A-KF
MINDMAN Air Cylinder MCGS-03-20-20
Festo Air Cylinder DSEU-50-320-P-A
Festo Air Cylinder ADNGF-16-80-P-A
ELCO Encoder EC40F8-H4PR-512
SIEMENS Actuator GEB166.1E
SMC Proportional Valve ITV2051-313N
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Endress Hauser Transmitter CM42-MGA000EAZ00
AirTAC Air Cylinder SC63X380
Sanyo Denki Fan 109E5724K5D09
Kikawa Water Pump CMD-50 380V
Recent related posts
-
08/03/2020
HVAC essential! Three steps to accurately calculate the cooling capacity of central air conditioning
The cooling capacity calculation of central air-conditioning is divided into three steps: 1. Calculate the actual cooling capacity required: Calculate according to the practical area of the room (carpet area, the floor area of the home can be deducted from the floor area); 150 watts per square meter;
-
08/08/2020
Types and differences of various refrigerants
Types and differences of various refrigerants 1. R22 is widely used in my country. Some experts believe that if R123 can finally be lifted, then the day when R22 is lifted will not be far away.
-
08/10/2020
Benefits and methods of condensate recovery
Benefits and methods of condensate recovery<br></br> 1. Why should we recycle condensate<br></br> Steam as a clean and safe energy carrier is widely used in various industries. After the steam releases the latent heat of vaporization in the steam-using equipment,
-
03/22/2022
What is an Expansion Valve?
The expansion valve is an important part of the refrigeration system and is generally installed between the liquid storage tank and the evaporator.
-
07/18/2020
How to protect the refrigeration compressor
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
08/04/2020
The advantages and disadvantages of the fluorine system and the water system are compared!
The advantages and disadvantages of the fluorine system and the water system are compared! Central air-conditioning is mainly divided into two categories: fluorine system and water system, both of which are connected to multiple indoor units by one outdoor unit,
-
01/10/2023
5 Refrigeration Solenoid Valve Failures and the Solutions
Refrigeration solenoid valve is an industrial equipment controlled by solenoid. It adjusts mass direction, flow, speed and other parameters in industrial control systems.
-
07/14/2020
How to solve the low-pressure fault during the operation of the chiller?
How to solve the low-pressure fault during the operation of the chiller? The chiller belongs to industrial machinery and equipment.
-
08/15/2020
Is the filter of the refrigerator clean or replaced
What is the filter of the refrigerator? Regardless of whether the refrigerator is air-cooled or water-cooled, there is actually a filter. The filter is generally used together with a desiccant, called a drier. What is the function of the filter?
-
09/06/2022
What is the Difference between Synchronous and Induction Motor
Electric motors are roughly divided into three types, synchronous motor, asynchronous motor