Piston diameter: 12 mm
Type code: DFM-B
Drive unit operating mode: Yoke
Cushioning: Elastic cushioning rings/pads at both ends
Mounting position: Any
Guide: Sliding guide: Recirculating ball bearing guide
Design: Guide
Position sensing: For proximity sensor
Variants: Heat-resistant seals max. 120Celsius Degree
Operating pressure: 2 bar - 10 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
Explosive ambient temperature: -20Celsius Degree <= Ta <= +70Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 2 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 0 - No corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -20 to 120 Celsius Degree
Theoretical force at 6 bar, retracting: 51 N
Theoretical force at 6 bar, advancing: 68 N
Alternative connections: See product drawing
Pneumatic connection: M5
Note on materials: RoHS-compliant
Cover material: Wrought aluminum alloy
Seals material: NBR
Housing material: Wrought aluminum alloy
Piston rod material: High-alloy stainless steel
Festo Air Cylinder DFM-12-10-B-P-A-KF
People who bought this item also viewed
Festo Air Cylinder AEVULQZ-16-10-P-A
CHANTO Air Cylinder JSR32X10B
Festo Air Cylinder ADN-20-50-I-P-A
Festo Air Cylinder ADN-20-40-A-PPS-A
Festo Air Cylinder DSBG-160-400-PPVA-N3
Festo Air Cylinder ADVU-12-50-P-A
AirTAC Air Cylinder ACQ40X10S
Festo Air Cylinder DSM-10-240-P-A-FF-FW
Festo Air Cylinder STAF-80-40-P-A-R
CHANTO Air Cylinder ASR63X200
SUMTAK Encoder IRH350-2500-014
KOGANEI Solenoid Valve F10T1-R-PS
Honeywell Actuator OM-P7-E
SMC Proportional Valve ITV1050-012CL
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNX Sensor EX-21AD
WINMOST Solenoid Valve WD-G03-B9B-A1
Panasonic Relay JS1-F-B-48V-FT
YUASA Battery NPH16-12T
IFM Sensor ID5072
Recent related posts
-
06/26/2023
Why is My Fridge Not Cooling & How to Fix
A refrigerator is one of the most important appliances in any home. It keeps your food fresh and prevents spoilage. However, if your fridge is not cooling, it can be a cause for concern.
-
08/12/2022
Introduction of 5 Common Linear Motors
Linear motors (direct drive linear motor), like rotary motors, also have two main application areas: drive and control.
-
08/02/2020
When air conditioners lack fluoride, five common leak detection methods will teach you who don’t understand!
When the air conditioner is lack of fluoride, the detection of leaks is the primary task of leakage repair. Today we introduce five common leak detection methods for you, namely fluorescent leak detection, soapy water leak detection
-
10/20/2021
Air Compressor Troubleshooting and Solutions
With the development of motor technology, compressor is considered as "general machinery", especially in coal chemical industry, machinery industry and other industries.
-
08/02/2020
Basic principles of data center cooling and energy saving solutions
Each data center has its own characteristics, so there is no technical solution that can be applied to any data center. This document mainly discusses some basic principles and technical issues in data center cooling and energy saving.
-
09/12/2022
Differences between Circuit Breaker and Isolator Switch?
A circuit breaker refers to a switching device that can close, carry and break current under normal circuit conditions and can do the same under abnormal circuit conditions within a specified time.
-
08/17/2020
What should I do if the compressor current of an industrial chiller is overloaded? okmarts.com editor has a coup!
The compressor current overload phenomenon of industrial chillers, cause analysis and solutions. The "overcurrent" here refers to the current overload of the chiller compressor.
-
02/29/2024
Freezer Fan Not Working: Common Reasons and Troubleshooting Steps
A malfunctioning freezer fan can be a source of frustration for anyone relying on their freezer to keep food items fresh and properly preserved.
-
02/16/2023
Installation and Maintenance of Gearbox
When you select gearbox model, four factors should be given comprehensive consideration.
-
03/17/2021
Several effective tips for servo motor drive repair
1. When the Panasonic digital AC servo system is powered on, the motor vibrates and makes a lot of noise, and then the driver gives an alarm No. 16, what should I do?