There is no price at present, you can Request a Quote
Stroke: 2 mm - 2000 mm
Piston diameter: 40 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Piston rod at one end: High corrosion protection: Special thread on piston rod: With end-position locking at both ends: Increased service life: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Low friction: Continuous, hollow piston rod: With rear end-position locking: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Heat-resistant seals max. 120Celsius Degree: Clamping unit on the piston rod: Constant, slow movement: Temperature range -40 to 80 Celsius Degree: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: With anti-twist protection: Extended piston rod: Dust protection: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: With front end-position locking: Internal thread on piston rod: Piston rod with external hexagon: Through piston rod: Extended external thread piston rod: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated
Protection against torsion/guide: Square piston rod
Operating pressure: 0.2 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 2 (ATEX): Zone 1 (ATEX): Zone 21 (ATEX): Zone 22 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.2 J
Max. torque for protection against rotation: 1.1 Nm
Theoretical force at 6 bar, retracting: 633 N
Theoretical force at 6 bar, advancing: 633 N - 754 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/4
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-40-50-PPV-A-Q
There is no price at present, you can Request a Quote
People who bought this item also viewed
CAMOZZI Air Cylinder 61M2P063A0305
Compact Air Cylinder QJ92-1642-A
MINDMAN Air Cylinder MCQV2-11-40-200
Festo Air Cylinder DGSL-4-10-PA
Festo Air Cylinder AEVC-32-10-I-P-A
Festo Air Cylinder DPZJ-20-100-P-A-S2
Festo Air Cylinder DGSL-20-10-P1A
Festo Air Cylinder DPZ-10-25-P-A-S6
Festo Air Cylinder DSN-16-50-P
Festo Air Cylinder DSNU-40-125-PPV-A
MINDMAN Air Cylinder MCGB-03-16-10
Eltra Encoder EL63D4096S5L9X3JR
CML Solenoid Valve WH43-G02-C2-D12-N-20
SIEMENS Actuator GLB131.1E
SMC Proportional Valve ITV2050-31F3CS3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LG LS Contactor GMD-9
Rockwell Allen-Bradley AB VFD 20P41AE1K3RA0NNN
Recent related posts
-
06/13/2020
Causes, treatment and prevention of liquid shock in refrigeration compressor
Causes, treatment and prevention of liquid shock in refrigeration compressor Liquid shock refers to the situation where the refrigerant fails to absorb heat or evaporates sufficiently, and the refrigerant liquid or wet steam is sucked into the compressor 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦
-
06/24/2020
Why the air conditioner does not cool
The cooling load is overloaded or the space is too large, the number of air conditioners is not correct; improper installation will cause poor air circulation, resulting in poor cooling effect; when the freon in the air conditioner is insufficient, it will cause the cooling effect of the air conditioner to deteriorate; the air conditioner is not on time Do cleaning and maintenance, etc.
-
02/05/2023
What is an Actuator?
From electronic access control systems, vibrators on cell phones and home appliances to vehicles, industrial equipment and robots, actuators are present in almost every machine around us.
-
06/13/2020
How much future does using water as refrigerant
How much future does using water as refrigerant Refrigeration technology is always developing in the direction of high efficiency and environmental protection, but is it very futuristic to use water as a refrigerant?
-
08/11/2021
How to Tell if Your Refrigerator Compressor is Bad
The refrigerator malfunction may be caused by the refrigeration system or the electrical system. When judging the compressor fault
-
09/11/2020
What are the tips for using screw air compressors
The set unloading pressure of the air compressor pressure regulator is adjusted with the upper adjusting bolt. Turn the bolt clockwise to increase the unloading pressure, and rotate it counterclockwise to reduce the unloading pressure. The differential pressure value is adjusted by the differential knob at the bottom. Turn it counterclockwise, the pressure differential value of the air compressor decreases, and clockwise
-
08/31/2022
Advantages of a Permanent Magnet Contactor
The permanent magnet contactor is a new type of low-voltage switchgear. Using the working principle of electromagnetic operation and permanent magnet holding
-
06/13/2020
About the six advantages of the fresh air system and the four details that need attention
About the six advantages of the fresh air system and the four details that need attention With the continuous improvement of living standards, coupled with whether the haze weather is invading, the fresh air system is gradually becoming a necessary choic ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜
-
09/15/2021
6 Reasons for Refrigeration Compressor Not to Start
When speaking of air conditioners, everyone is familiar with them. Especially in the hot summer, we would not know how to live without it.
-
08/19/2020
Which air conditioner, floor heating, or radiator consumes the most electricity
At present, the household heating methods of the residents in the north and south of our country are becoming more and more diversified. Radiators, air conditioners, and floor heating are the three most common household heating methods.