There is no price at present, you can Request a Quote
Stroke: 2 mm - 2000 mm
Piston diameter: 50 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Clamping unit on the piston rod: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Piston rod at one end: Low friction: Extended piston rod: Increased service life: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Temperature range -40 to 80 Celsius Degree: Special thread on piston rod: Through piston rod: Internal thread on piston rod: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Piston rod with external hexagon: With anti-twist protection: High corrosion protection: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Dust protection: With rear end-position locking: Extended external thread piston rod: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: With front end-position locking: With end-position locking at both ends: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Continuous, hollow piston rod: Constant, slow movement
Protection against torsion/guide: Square piston rod
Operating pressure: 0.2 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 2 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.2 J
Max. torque for protection against rotation: 1.5 Nm
Theoretical force at 6 bar, retracting: 990 N
Theoretical force at 6 bar, advancing: 990 N - 1178 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/4
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-50-80-PPV-KP
There is no price at present, you can Request a Quote
People who bought this item also viewed
CHANTO Air Cylinder JSR32X10B
AirTAC Air Cylinder SC40X70
Festo Air Cylinder DSNU-25-40-P-A
Festo Air Cylinder DGSL-12-30-Y3A
Festo Air Cylinder ADN-20-60-A-P-A
Festo Air Cylinder ADN-32-80-I-P-A
Festo Air Cylinder DNC-63-240-PPV-A
Festo Air Cylinder SLT-16-80-P-A
Festo Air Cylinder ADVULQ-16-5-A-P-A
Festo Air Cylinder DFM-20-80-B-PPV-A-KF
Daikin Solenoid Valve KSO-G02-20DD-30
Belimo Actuator GRK24A-MF-7
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Sanyo Denki Fan 109S492
Recent related posts
-
06/28/2020
Hitachi compressor model sample parameters
Hitachi compressor model sample parameters W Cooling Capacity Btu/h COP (A) Compressor (B)
-
08/11/2023
How Does a Heat Pump Work in Winter?
Heat pumps are an excellent alternative to traditional heating systems, particularly in areas with mild winters. Unlike traditional heating systems that rely on burning fuel or electricity to generate heat
-
02/13/2024
A Comprehensive Guide to Parts of a Furnace
When winter arrives and the chill sets in, a reliable furnace becomes a crucial component of any home's heating system.
-
07/07/2023
Why Heat Pump Compressor Starts Then Stops: Common Causes and Solutions
A heat pump compressor that starts and then stops can be a frustrating and potentially costly issue. A malfunctioning compressor can cause inefficient operation, poor heating or cooling performance, and even complete system failure.
-
01/07/2021
Today in the air-conditioning market is tomorrow for fresh air systems
Today in the air-conditioning market is tomorrow for fresh air systems Now we have a fresh air system for work and life, so that even if we are in a closed building environment, we can breathe fresh air. In fact, today's fresh air system has also gone 器2 䀀
-
08/03/2022
Differences Between Overflow Valve and Pressure Relief Valve
Overflow valve is to prevent system overload and ensure safety. The pressure relief valve reduces the system pressure on the premise that the system is not overloaded.
-
06/14/2020
This is the reason for the overheating of refrigeration compressor exhaust~!
This is the reason for the overheating of refrigeration compressor exhaust~! The main reasons for the exhaust temperature overheating are as follows: high return air temperature, large motor heating capacity, high compression ratio, high condensation pre 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁
-
10/16/2020
Copeland compressor installation steps
The compressor is regarded as the heart of the refrigeration system, and the actual responsibility of the compressor is to increase the pressure and bring the suction pressure state to the discharge pressure state. Emerson Copeland compressors are used in a wide range of applications and have a high degree of attention. Below, okmarts.com will introduce the steps and precautions for installing Copeland compressors.
-
08/20/2020
How much power does the air conditioner save most
With the advent of the dog days, T-shirts and long skirts have been unable to meet people's needs for cooling off, so various cooling measures have been taken. Air conditioners are naturally the first choice to cool off the heat.
-
07/04/2020
In the post-new crown era, what are the market opportunities for refrigeration companies
In the post-new crown era, what are the market opportunities for refrigeration companies When we thought that the fear and anxiety caused by the new crown epidemic were going away, when we set up stalls in full swing to prepare for the development of the night economy, the small-scale counterattack of the new epidemic in Beijing made the originally slightly relaxed nerves tense again.