There is no price at present, you can Request a Quote
Stroke: 3 mm - 2000 mm
Piston diameter: 63 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Temperature range -40 to 80 Celsius Degree: With anti-twist protection: Piston rod with external hexagon: Continuous, hollow piston rod: Piston rod at one end: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Extended piston rod: With end-position locking at both ends: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: With rear end-position locking: Through piston rod: Increased service life: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Clamping unit on the piston rod: Internal thread on piston rod: Special thread on piston rod: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: High corrosion protection: Low friction: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Constant, slow movement: Extended external thread piston rod: With front end-position locking: Dust protection
Protection against torsion/guide: Square piston rod
Operating pressure: 0.15 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX): Zone 2 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress: 3 - High corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.5 J
Max. torque for protection against rotation: 1.5 Nm
Theoretical force at 6 bar, retracting: 1682 N
Theoretical force at 6 bar, advancing: 1682 N - 1870 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G3/8
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-63-200-PPV-KP
There is no price at present, you can Request a Quote
People who bought this item also viewed
AirTAC Air Cylinder JSI100X400S
Festo Air Cylinder DGP-32-600-PPV-A-B
CKD Air Cylinder STSB-4010
Compact Air Cylinder QJ92-1642-A
Festo Air Cylinder ADVU-63-80-P-A-S2
Festo Air Cylinder DFM-40-100-P-A-GF
Festo Air Cylinder ADN-25-60-A-P-A
Festo Air Cylinder DNG-200-100-PPV-A
Festo Air Cylinder DMM-10-25-P-A
Festo Air Cylinder ADVC-40-25-A-P-A
MINDMAN Air Cylinder MCGB-03-32-40
Festo Air Cylinder DFM-100-100-P-A-GF
Honeywell Actuator M6284A1055
SMC Proportional Valve ITV2011-31N2S4
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MAHLE Filter LA873
Recent related posts
-
08/13/2020
New Explanation of Basic Knowledge of Small Chiller System
Small chiller: is a kind of water cooling equipment, small chiller is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure.
-
01/04/2021
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor Piston Displacement, Compressor Capacity, Clearance Volume of Compressor Introduction This article describes some important terms related to the refrigeration and air 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵
-
07/22/2020
I only learned today that the dehumidification mode cannot be used indiscriminately when the air conditioner is turned on in summer, which consumes electricity and consumes compressors.
I only learned today that the dehumidification mode cannot be used indiscriminately when the air conditioner is turned on in summer, which consumes electricity and consumes compressors.
-
06/15/2020
Danfoss expands portfolio of oil-free compressors with new TGS490
Danfoss expands portfolio of oil-free compressors with new TGS490 Danfoss, the world’s leading manufacturer of oil-free compressor technology, has expanded the oil free compressor portfolio with the introduction of the TGS490.
-
03/15/2023
Four Characteristics of Water Pump in Energy Conservation
As we all know, the impeller is an important component in the composition of centrifugal pump that determines the water volume and head.
-
08/21/2020
What is a shell and tube condenser How can the chiller save more power
Recently, some friends left a message to okmarts.com asking what is a shell and tube condenser? How to operate the chiller to save electricity? Today, the editor of okmarts.com will take you to learn more, and hope the following content can help you.
-
08/01/2023
Why is My Heat Pump Freezing Up in Winter (Causes, Prevention, and Solutions)
A heat pump is an essential component of any HVAC system, providing both heating and cooling functions. However, during the winter months, it's not uncommon for homeowners to experience issues with their heat pumps freezing up.
-
08/21/2020
Common problems and solutions for ice making machines
1. Common problems and solutions of ice maker 1. The compressor is working but not cooling. Reason: The refrigerant leaks or the two-way solenoid valve is damaged and it is not closed tightly.
-
06/24/2020
Which refrigerator is better for cooling
Different cooling methods of refrigerators have different advantages, mainly depending on which cooling method is selected. The direct cooling refrigeration type is cheap, relatively energy-saving, and has good fresh-keeping and moisturizing properties, but the temperature is uneven, and it needs to be defrosted frequently.
-
08/28/2020
Learn about refrigerated dryers
In order for the compressed air system to function properly, the air must be dry. This means that before entering the air network, the air must have no liquid moisture and low relative humidity.