Stroke: 3 mm - 2000 mm
Piston diameter: 80 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Increased service life: Temperature range -40 to 80 Celsius Degree: Through piston rod: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: With rear end-position locking: Low friction: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Extended external thread piston rod: With anti-twist protection: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Continuous, hollow piston rod: Special thread on piston rod: With end-position locking at both ends: Constant, slow movement: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: With front end-position locking: Piston rod with external hexagon: Extended piston rod: Dust protection: Internal thread on piston rod: High corrosion protection: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: Piston rod at one end: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Clamping unit on the piston rod
Protection against torsion/guide: Square piston rod
Operating pressure: 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 2 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX): Zone 1 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress: 3 - High corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.9 J
Max. torque for protection against rotation: 3 Nm
Theoretical force at 6 bar, retracting: 2721 N
Theoretical force at 6 bar, advancing: 2721 N - 3016 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G3/8
Note on materials: RoHS-compliant
Cover material: Die-cast aluminum: Coated
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-80-500-PPV-A-KP
People who bought this item also viewed
MINDMAN Air Cylinder MCQV2-11-40-200
KOGANEI Air Cylinder NHBRS-10
CKD Air Cylinder SCPG2-M-00-10-30
Festo Air Cylinder DNC-32-25-PPV-A
Festo Air Cylinder DSBC-32-85-PPVA-N3
Festo Air Cylinder ADVU-32-35-A-P-A
Festo Air Cylinder ADN-25-10-I-P-A
Festo Air Cylinder DSBC-80-20-D3-PPVA-N3
Festo Air Cylinder DSM-32-270-CC-FW-A-B
Festo Air Cylinder DNC-63-700-PPV-A
Festo Air Cylinder ADN-16-15-A-P-A
Autonics Rotary Encoder ENA-60-2-T-24
CKD Solenoid Valve 4GD219-06-E2C-3
Honeywell Actuator M9494D1000
SMC Proportional Valve ITV1050-211L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNX Sensor GS-14M
Hitachi Compressor SH264DG-C7HQ1H
Festo Air Cylinder DGPL-40-200-PPV-A-KF
KCL Vane Pump DVQ25-32-F-RAR-02
Recent related posts
-
08/15/2020
Solution to the condensing pressure of the chiller refrigeration system
1. The condenser of the chiller is dirty Computer room chillers generally use air-cooled condensers, which are composed of multiple sets of coils, and fins are added to the coils to increase the heat transfer area on the air side.
-
08/14/2020
How to deal with moldy cold storage accessories
1. Analyze the reasons<br></br> Inspect the entire refrigeration system to confirm the cause of frost damage and find out the leaks
-
09/08/2020
Air compressor lubricant model the difference between No. 32 and No. 46 air compressor lubricants
Air compressor lubricants are generally No. 32 oil and No. 46 oil. No. 32 is a mineral type. The general service life is about 2000 hours and needs to be replaced. The operating temperature must be below 90 degrees to avoid carbon deposits.
-
09/11/2020
Several Improvements on the Easy Failure Points of Air Compressor
The original compressor has poor cooling effect and low efficiency. The improvement method is to introduce the water that enters the primary and secondary cylinders and the intercooler directly from the main pipe to the water collecting funnel after cooling.
-
09/08/2020
What is the difference between an air pump and an air compressor
Many people think that an air compressor is actually an air pump. Generally speaking, the basic principle is still the same, but there are differences in the actual structure. According to relevant data, the intake and exhaust of the air compressor have valves.
-
06/14/2020
This is the reason for the overheating of refrigeration compressor exhaust~!
This is the reason for the overheating of refrigeration compressor exhaust~! The main reasons for the exhaust temperature overheating are as follows: high return air temperature, large motor heating capacity, high compression ratio, high condensation pre 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁
-
07/23/2020
R410a and R22 refrigerant comparison application and installation specifications
1.Introduction to the properties of R410a refrigerant<br></br> 1. R410a is a HFCs refrigerant mixed with two working fluids of R32 and R125 at a mass fraction of 50% and 50%. It is a near-azeotropic mixture (pseudo-azeotrope), and its thermal performance is close to a single working fluid.
-
08/14/2020
What should I do if the screw compressor fails
Nowadays, in the summer, the use of air conditioners is increasing. If the screw compressor fails, how to repair it? First, check out where the fault is. After the inspection, repair or replace the damaged parts, as follows:
-
09/03/2020
Introduction of simple pressure vessel and fixed pressure vessel for air compressor gas storage tank
As the fourth most widely used energy source, compressed air is second only to traditional energy sources such as electric energy. As a necessary product for air compressors, compressed air is widely used in various fields of national production and life in my country.
-
08/16/2020
What should I do if the screw of the rod-type chiller bites to death