Piston diameter: 125 mm
Type code: DSBF
Cushioning: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Conforms to standard: ISO 15552
Piston rod end: External thread
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor
Symbol: 00991235
Operating pressure: 0.6 bar - 10 bar
Mode of operation: Double-acting
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 3 - High corrosion stress
Ambient temperature: -20 to 80 Celsius Degree
Impact energy in the end positions: 3.3 J
Cushioning length: 45 mm
Theoretical force at 6 bar, retracting: 6881 N
Theoretical force at 6 bar, advancing: 7363 N
Type of mounting: With accessories: With internal thread: Optionally:
Pneumatic connection: G1/2
Note on materials: RoHS-compliant
Cover material: Die-cast aluminum: Coated
Piston rod material: High-alloy stainless steel
Material of cylinder barrel: Wrought aluminum alloy: Anodized
Festo Air Cylinder DSBF-C-125-400-PPVA-N3-R
People who bought this item also viewed
Festo Air Cylinder DGC-25-625-KF-PPV-A
CKD Air Cylinder SCPG2-M-00-10-30
CHANTO Air Cylinder DXSL20X15
Festo Air Cylinder ADVU-25-10-P-A
Festo Air Cylinder DSNU-12-150-PPV-A
Festo Air Cylinder DNC-40-900-PPV-A
Festo Air Cylinder DFM-20-50-B-PPV-A-GF
MINDMAN Air Cylinder MCJS-12-20-15
MINDMAN Air Cylinder MCQA-11-125-800M
AirTAC Air Cylinder ACQ12X10
KOGANEI Air Cylinder NHBDPG-16
TR Encoder CEV58M-00417
Johnson Controls Actuator M9104-AGA-3S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TCS Oil Seal TC 27*49*10
SCHNEEBERGER Linear Guideway MRA45-G2V1
Mitsubishi Circuit Breaker NF125-SW
Nidec Fan V35132-16F
Recent related posts
-
08/05/2020
Why does the refrigeration compressor produce overheat protection What matters should be paid attention to in the use of overload protector
The working principle and classification of the overload protector. The overload protector of the compressor for air conditioning generally adopts a snap-type bimetallic protector, which consists of a heating wire,
-
07/29/2020
Types of refrigeration and air conditioning piping and calculation formula for wall thickness
Types of refrigeration and air conditioning piping<br></br> The types of refrigeration and air-conditioning piping are classified into the first, second, and third types according to the highest operating pressure (design pressure).
-
08/19/2020
How to operate cold storage to save electricity
How can the cost of cold storage operation be reduced is a point of concern for many people. The operation cost of cold storage is mainly composed of electricity, maintenance, management fees and other miscellaneous items. Today, let's talk about how cold storage can save electricity.
-
09/11/2020
How to use empirical methods to inspect rolling bearings
How to use empirical methods to inspect rolling bearings Some operators lack the experience in identifying rolling bearings and continue to use them as long as they see no obvious damage to the rolling bearings, causing serious failures later. Some people only need to remove the rolling bearings and replace them without inspection.
-
07/04/2023
Don't Sweat It: How to Troubleshoot and Fix an AC Blowing Warm Air
When the weather gets hot, there's nothing more frustrating than an air conditioning unit that blows warm air. Not only is it uncomfortable, but it can also be a sign of a more serious problem with your AC system.
-
03/03/2021
Control mode of servo motor
Torque control: the torque control mode is to set the external output torque of the motor shaft through the input of external analog quantity or the assignment of direct address. For example, if 10V corresponds to 5nm, when the external analog quantity is set to 5V, the output of the motor shaft is 2.5nm: if the load of the motor shaft is lower than 2.5nm, the motor will rotate forward, and when the external load is equal to 2.5nm
-
08/15/2020
How to manage the temperature after the cold storage is built
After the cold storage is built, the temperature in the cold storage must be better adjusted. This content is actually very important, but the corresponding precautions should also be grasped in the process of adjusting the temperature of the cold storage.
-
11/30/2021
Differences Between Sensor and Transmitter
Sensors and transmitters play an important role in the field of automatic control. Transmitters are developed based on sensors, which have close relationship and differences.
-
08/25/2020
Honeywell adds new functions to ENTIS to strengthen the tank farm inventory management system
Honeywell recently announced the addition of new functions to the ENTIS inventory management system to further improve integration and safety, and help oil storage terminals achieve compliant
-
08/20/2020
How to extend the life of commercial central air conditioners
Nowadays, buyers of commercial central air conditioners are increasing day by day. Many people find that the service life of commercial central air conditioners is greatly reduced after purchasing.