Rated current(A): 15
Pole number: 3
Fuji Circuit Breaker SA53RCUL-3P15A
People who bought this item also viewed
Fuji Circuit Breaker EW32EAG-3P030
Fuji Circuit Breaker EW32AAG-2P020
Fuji Circuit Breaker BW250EAG-3P150
Fuji Circuit Breaker EW50SAG-3P050K
Siemens Circuit Breaker 5SY4220-7
Siemens Circuit Breaker 5SY4320-7
Siemens Circuit Breaker 3RV1011-0FA10
TRIAD Transformer N-57M
Shilin Contactor S-P25 110V
OBO Surge Protection Device MDP-4 D-24-T
Siba Fuse DIN-43625
TYCO Relay MT338115
UniOhm Resistor 1206W4F160KT5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Contactor 3RA2417-8XH31-1BB4
PARKER Filter 928339Q
NEW-ERA Air Cylinder PPT-SD10-10-TP
Recent related posts
-
08/27/2020
Compressor overhaul and correct installation matters, super complete and detailed
Content covered by compressor overhaul Compressors generally need to be overhauled after 12,000-26,000 hours of operation. In addition to all the work required for intermediate maintenance,
-
07/31/2020
The 8 accessory usages that must be mastered when using computer room air conditioners!
The electrical control and air circulation of the computer room air conditioner are independent units. During maintenance and overhaul, the air conditioner does not need to be turned off, and the stable air flow and temperature gradient in the air conditioner room can also be ensured
-
09/10/2020
Causes of Compressor Common Failures and Countermeasures Analysis
Abstract: During the operation of the compressor, some failures and even accidents will inevitably occur. A fault refers to an abnormal condition that occurs during the operation of the compressor, which can be restored to normal operation once the compressor is eliminated, while an accident refers to a damage situation. The two are often related, and if the fault is not eliminated in time, it will cause a major accident.
-
06/14/2020
Identify the failure of a fully enclosed refrigeration compressor in three minutes
Identify the failure of a fully enclosed refrigeration compressor in three minutes 1. How to identify the three binding posts on the casing of the hermetic compressor?
-
07/08/2020
How to solve the problem of poor oil return of screw chiller
1. What is the cause of the poor oil return of the screw chiller? Generally speaking, the reason for the poor oil return of the screw chiller is mainly due to the phenomenon of the gas mixture of lubricating oil and refrigerant during the operation. Specifically, in the operation of the refrigeration system, encountering the miscibility of the refrigerant and the refrigerator lubricating oil will cause the lubricant in the refrigeration compressor to run and the refrigerant will be discharged into the condenser in the form of gas mist and droplets.
-
08/11/2020
The price of central air-conditioning varies greatly, and the purchase of central air-conditioning needs to consider 4 major factors
In this era of rising living standards, air conditioning has become an essential part of our lives and plays an important role in it. It is for this reason that the air-conditioning market has become more complicated
-
03/04/2024
Industrial Exhaust Fan: Working Principle, Features & Application
Exhaust fans are a type of ventilation equipment that can be divided into the following types according to usage scenarios and functional characteristics
-
06/21/2020
Common system failures of refrigeration equipment
Common system failures of refrigeration equipment 1. Liquid return: For refrigeration systems using expansion valves, liquid return is closely related to the selection and use of expansion valves. Expansion valve selection is too large, the superheat setting is too small, the installation method of the temperature sensor is incorrect, the insulation bandage is damaged, and the expansion valve failure may cause liquid return.<img src="{{media url="Common_system_failures_of_refrigeration_equipment2.png"}}" alt="" />
-
06/14/2020
Detailed process of refrigeration compressor replacement
Detailed process of refrigeration compressor replacement After confirming that there is only a problem with the compressor and it needs to be replaced, proceed to prepare for the replacement of the compressor. Specific steps are as follows:
-
09/07/2020
An article to fully understand the principle, failure and maintenance of nitrogen compressors
Nitrogen compressors are mainly used in various industrial needs. Pipes are used to connect the original air inlet of the nitrogen compressors and the balance gas tank. When the sealing performance of the sealing box is not very good, the pipeline provides a certain pressure ,