There is no price at present, you can Request a Quote
Fuji VFD Frequency Converter FRN0240E2S-2E
There is no price at present, you can Request a Quote
People who bought this item also viewed
Fuji VFD Frequency Converter FRN2.2G9S-4
Fuji VFD Frequency Converter FVR2.2E9S-2
Fuji VFD Frequency Converter FRN1.5G11S-4
Panasonic Servo Motor MDME302SCD
Johnson Controls Actuator M9116-HGC-2
COSEL Power Supply LEP240F-36-C
Siemens PLC 6ES7288-1CR30-0AA1
Newstart Speed Reducer PF130L3-75-P2-S2
MITSUBISHI Spindle Amplifier MDS-B-SPJ2-55
FUJI IGBT Module 1MBI2400VD-170E
WAGO Relay 788-404
GE Battery SKZE-161094722415536
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNON Fan ME92251VX-Q010-F99
Festo Air Cylinder DFM-80-160-P-A-GF
Rockwell A-B Sensor 42CM-E1EZB-D4
Yaskawa Servo Drive SGDA-A3BP
Recent related posts
-
10/10/2023
How to Clean a Portable Ice Maker: Tips and Tricks
A portable ice maker is a convenient appliance that allows you to make ice anywhere, anytime. Whether you're hosting a party, camping, or simply need ice for your drinks, a portable ice maker can make your life easier.
-
07/01/2020
Experts teach you how to maintain the compressor in summer
Experts teach you how to maintain the compressor in summer The summer is coming, and the maintenance of various mechanical equipment needs to be done properly. Otherwise, this hot and humid weather in summer will cause many machines to be damaged and affect the operation, resulting in a reduction in work efficiency. How to maintain the compressor in summer? Let's take a look.
-
01/13/2021
Gas stove solenoid valve working principle and classification
In gas stoves, the working principle of the solenoid valve is to control the mechanical movement by controlling the current of the electromagnet. There is a closed cavity in the solenoid valve of the gas stove, and there are through holes in different po 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ٺ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/27/2020
Ten reasons for the burning of air conditioning compressors
During the starting process of the air conditioner compressor, there is generally a step-down starting circuit, but the starting current will exceed several times the rated current, and the starting temperature of the air conditioner compressor motor will rise very quickly.
-
06/14/2020
What is an air-cooled heat pump Introduction of knowledge about air-cooled heat pump
What is an air-cooled heat pump Introduction of knowledge about air-cooled heat pump What is an air-cooled heat pump-Introduction to an air-cooled heat pump
-
09/07/2020
Not as simple as you think, there are three states of mechanical lubrication
Lubrication is a frequently encountered problem in equipment maintenance, but what exactly is lubrication? Speaking of lubrication, the scene in our minds may just apply oil or grease to the mechanical friction surface to reduce friction.
-
09/11/2020
How to use empirical methods to inspect rolling bearings
How to use empirical methods to inspect rolling bearings Some operators lack the experience in identifying rolling bearings and continue to use them as long as they see no obvious damage to the rolling bearings, causing serious failures later. Some people only need to remove the rolling bearings and replace them without inspection.
-
07/19/2020
Types of refrigeration compressors for industrial chillers
The energy efficiency ratio of the chiller compressor of the chiller unit determines the energy efficiency ratio of the entire refrigeration system. Since the ambient temperature changes, the compressor is in a partial load state most of the time, so the compressor must have energy regulation.
-
01/02/2021
Mads Clausen - the founder of Danfoss
From just a single valve and an unquenchable desire to succeed, Danfoss founder, Mads Clausen, created a global business that still sets the standard for innovation today.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.