Experts teach you how to maintain the compressor in summer

Experts teach you how to maintain the compressor in summer The summer is coming, and the maintenance of various mechanical equipment needs to be done properly. Otherwise, this hot and humid weather in summer will cause many machines to be damaged and affect the operation, resulting in a reduction in work efficiency. How to maintain the compressor in summer? Let's take a look. Taikang Compressor has entered the summer. Despite the hot weather, there will be one to three days of rain within a week. In this cloudy and uncertain season, the humidity in the air will change differently, sometimes the humidity is very high. As the humidity of the air increases, the air entering the compressor will naturally increase the formation of water vapor. The moisture generated by the position of the paint intake valve will increase. During the loading and unloading of the air compressor, a part of the air is taken into the discharge pipe and passes through the pipe. The cold and heat exchanges form water vapor, which increases the amount of sewage discharged. This is one of the factors. There is also a phenomenon that frequent loading and unloading of the compressor is a very necessary normal operation of the air supply system of the compressor. The loading is to deliver gas to the air supply pipe of the compressor, and the unloading is to have a pipe network system. buffer. Just like a heartbeat, the pipe network system will over-expand when it is loaded; the unloading time is too long, and the gas supply system will not use enough gas to meet user needs. With frequent loading and unloading, the time for the air to be drawn into the intake valve is shortened. A large amount of air enters the sewage system along the exhaust pipe, and cannot fully enter the twin screw part of the host for compression. This part of the gas becomes another factor for the increase in the sewage.   Coolers are divided into two types: air coolers and oil-cooled coolers. The structures of air coolers and oil-cooled coolers are similar, but there are also differences. The cooler is composed of countless copper tubes. According to the size of the air compressor, the size of the air compressor cooler is also different. The air cooler is the wind in the copper pipe, and the oil cooler is the water in the copper pipe. The probability of the cooler leaking is very small, but it is not non-existent. Because of the scale clogging, it increases the chance of cooler leakage. Also due to changes in water temperature, it may be that the high temperature of the air cannot be normally reduced to a reasonable range, resulting in excessive exhaust gas temperature and increased pressure. In addition to the loosening of the connection part of the cooler, the possibility of leakage can occur.   Compressor post-processing filter has two, one at the front end of the post-processing, and one at the rear end, which consists of several filter elements inside. The post-processing equipment uses a combination dryer. The combination dryer adds a refrigeration system to the adsorption dryer. It uses Freon refrigeration and compression technology to cool the compressed air and enter the adsorption drying system for drying. Due to the long running time of our post-processing equipment and the infrequent maintenance, the active alumina and molecular sieve components in the adsorption barrel are partially powdered. With the increase of water in the air, the post-processing filter is gradually added Blocked. It directly leads to poor drying effect, because the air humidity of the air compressor increases, and the humid air cannot be sent out normally from the post-treatment filter. Only the pipes of the sewage system are mixed with other sewage, and the water vapor content is large, which causes sewage. Large amount of water. Due to the blockage of the post-treatment filter, the drainage volume is increased, and the humid air from the air storage tank is not dried in time, resulting in a large amount of condensate season. These condensate cannot be quickly converted into dry air. Under the effect of the refrigerant system, Quickly discharge, cure through the drain valve. This increases the burden of the blowdown valve, and at the same time, by taking some shots through the electronic drain valve, the amount of blowdown water is also greatly increased.   So much knowledge about summer maintenance of compressors, okmarts.com provides a variety of compressor products, including Mitsubishi compressors, Hitachi compressors, Bristol compressors, Taikang compressors, Copeland compressors and so on. If you have any need, you can contact us!

Recent related posts

Customers frequently viewed

Submitted Successfully
Submission Failed