Operation: double acting
Fluid: air
Operation ambient temperature range: 0 - 60 degree celsuis
Specification: 100
FULOS Air Cylinder HRQ100A
People who bought this item also viewed
FULOS Air Cylinder HRQ20A
FULOS Air Cylinder HRQ30A
FULOS Air Cylinder HRQ10A
Festo Air Cylinder DNC-125-1500-PPV-A-KP
Festo Air Cylinder DSNU-12-30-P-A
Festo Air Cylinder ADN-50-15-I-P-A
Festo Air Cylinder ADN-40-40-A-P-A
Eltra Encoder EL63D1000S5/28P8X6MR
MAC Solenoid Valve 45A-AD1-DDAJ-1JB
Belimo Actuator TF230-S
SMC Proportional Valve VER4000-04
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
VISHAY Capacitor MKP1839318251R
SMC Proportional Valve ITV2010-012BS3
HENGSTLER Encoder RI58-D/4096EF.47IF
Recent related posts
-
07/16/2020
Compressor overheating
The compressor is overheated, causing it to stop shortly after start-up (protector action). Please check whether it is:; Insufficient or excessive refrigerant, please fill the leak and evacuate, add enough refrigerant or release excess refrigerant. The capillary assembly (including the filter) is clogged and the suction temperature rises. Please replace the capillary assembly.
-
07/31/2020
Fresh air treatment and energy-saving methods of multi-line system
In the process of using air conditioners, we must consider the related functions of air conditioners on the one hand, and on the other hand, consider its energy-saving effects and reduce power consumption. The multi-line system can meet people’s needs in life while reducing input costs. Reduce energy consumption.
-
07/22/2020
I only learned today that the dehumidification mode cannot be used indiscriminately when the air conditioner is turned on in summer, which consumes electricity and consumes compressors.
I only learned today that the dehumidification mode cannot be used indiscriminately when the air conditioner is turned on in summer, which consumes electricity and consumes compressors.
-
06/14/2020
Reliability-up (Compressors)
Reliability-up (Compressors)
-
09/03/2020
The customer says the price is high, what should the air compressor seller do
After quoting customers, we often encounter such a problem, "Your price is too high". Strictly speaking, it is not a rejection of the question "your price is too high" raised by the customer. This is actually a positive signal.
-
03/10/2021
The main circuit fuse fusing is a common fault of SCR servo driver. The causes of fuse fusing are as follows
The "phase sequence" of power incoming line is incorrect. Due to the synchronization problem between the trigger pulse and the main circuit of SCR servo driver, there are strict requirements on the "phase sequence" of the input power supply. If the "phase sequence" is not correct, connecting the power supply may immediately cause the fuse of the main circuit of the driver to blow.
-
07/28/2020
Common faults and solutions of screw chillers
Low voltage overrun protection:<br></br> Solution: Replace or clean the filter element; clean the suction port filter.<br></br> Dirty or ice blockage at the inlet of the expansion valve:<br></br> Solution: Dirty blockage: remove the expansion valve and clean it. Ice blockage: replace the filter drier and run again
-
01/14/2021
Do you know these 10 questions about air conditioning?
Fluorine deficiency: If the air conditioner in your home is an old-fashioned air conditioner that has been used for a long time, it may be because the Freon refrigerant in the air conditioner is gone, and you can continue to use it only by adding Freon. 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֖ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/14/2020
Compressor operation requirements
Compressor operation requirements The first load operation of the compressor is carried out after the empty vehicle operation and purging are completed. The compressor should be operated according to the following requirements:
-
06/14/2020
How about ultra-small refrigeration compressors Features introduction of ultra-small refrigeration compressors
Among the components of our refrigeration compressor, the compressor is very important, and an ultra-small refrigeration compressor is widely used in our equipment with a refrigeration capacity of less than 1KW, so today I will introduce you to us Some of 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜