Series:ZSY
Size:250
Ratio:80
Assembly form: I
GUOMAO Reduction Drive Gearbox Speed Reducer ZSY250-80-I
People who bought this item also viewed
Fanuc Servo Motor A06B-0075-B303
JSCC Speed Reducer 90GK500RC
Crouzet Electric Motor 82861010
GATES Belt 415-5GT
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CARLO Relay RM1A40A50
YTP Linear Guideway SBR30MUU
Honeywell Sensor HTL-Q05PIS-S
Recent related posts
-
07/28/2020
Condenser cleaning judgment, method and operation are all here!
Condensers are prone to scale formation in the pipes after long-term use. If they are not treated in time, these scales will affect the heat exchange effect and cause the condensing temperature of the unit to increase,
-
06/22/2020
What to do if the air conditioner is not cooling
Air conditioning does not refrigerate mainly from the following aspects to solve: 1, regular cleaning and maintenance of air-conditioning outside machine. 2. Replace the old air conditioner that has exceeded the service life. 3. Check whether the copper pipes of the indoor and outdoor units of the air conditioner are too long. 4. Check whether the power of the air conditioner matches the indoor space. 5. Check whether the installation environment of the air conditioner is suitable. 6. Replenish refrigerant. <img src="{{media url="magefan_blog/What_to_do_if_the_air_conditioner_is_not_cooling.jpg"}}" alt="" />
-
01/25/2024
Industrial Control Cabinet Cooling: How to Design the Cooling and Ventilation System?
Control cabinets, such as wind turbine electrical control cabinets, realize system power distribution, monitoring and control of the entire unit.
-
01/03/2023
How does Solenoid Coil Work?
Solenoid coils are built using the presence of a magnetic field around a wire. It is wound in a spiral shape to strengthen the magnetic field, i.e.
-
09/09/2020
What are the problems of traditional air compressors compared with frequency conversion air compressors
Variable-frequency air compressors have certain advantages in many aspects, so what are the problems of traditional air compressors compared to variable-frequency air compressors? Today I will tell you about the problems of traditional air compressors.
-
09/27/2022
What is the Difference Between Piston and Plunger Pumps
Plunger and piston pumps are very similar in construction and both are reciprocating positive displacement pumps.
-
06/14/2020
It is so simple to change the oil in a half-sealed piston compressor, can you
It is so simple to change the oil in a half-sealed piston compressor, can you? The semi-hermetic piston compressor must pay attention to the condition of the freezing oil during the first 500 hours of operation
-
12/18/2021
Basics of Encoder and Orthogonal Coding
Encoder is a kind of electromechanical equipment, which can be used to measure the movement of machinery or the target position of machinery.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
05/17/2023
How to Add Oil to AC Compressor
When the all-in-one air conditioner leaves the factory, there is a sufficient amount of AC compressor oil (commonly known as refrigeration oil, refrigerant oil, AC lubricants, AC oil) inside the machine.