Series | G Series |
Type | Highly Compressors |
Refrigerant | R-410A |
Displacement cm3/ revolution | 1.0 |
Phase | 1Ph |
Voltage | 220-240V |
Hz | 50Hz |
Parameter Merge | Series |
Type | Highly Compressors |
Refrigerant | R-410A |
Rated Output HP | - |
Displacement cm3/ revolution | 1.0 |
Phase | 1Ph |
Voltage | 220-240V |
Hz | 50Hz |
Hitachi Compressor ASG108SW-B7AT
Brand : |
Hitachi |
Model : |
ASG108SW-B7AT |
Refrigerant/use : |
R410A |
Number of Cylinder : |
S |
Series : |
G |
Displacement : |
108Cm³/rev |
Compressor performance scale : |
High Efficiency |
Power : |
110/115-120V,60Hz |
Starting method : |
KP (1 ᴓ) |
Compressor base type : |
B |
Dimension accumulator : |
7A |
Angle φ of Triangle Base & Accumulator : |
T |
Special Specification : |
N/A |
Color : |
Black |
After service : |
|
Place of origin : |
China |
Applications:
+ Industrial cabinets
+ Dehumidification
+ Medical technology
+ Compressed air technology
+ Dehumidification units
+ Vending machine
+ Heat pump
+ Air conditioners
+ Laboratory and testing equipment
Feature:
High Efficiency
Large capacity range
Low-vibration, smooth running
Low noise level
Low-priced
Hitachi Compressor ASG108SW-B7AT
People who bought this item also viewed
Mitsubishi Compressor RB233YABC
GMCC Compressor PA270X3CS-3MUU
Sanyo Compressor C-2RN153H3A
Hitachi Compressor 603DH-90C2Y
Hitachi Compressor E406AHD-36A2Q
Hitachi Compressor 303DHV-47D2
Hitachi Compressor SL193SV-C7LU
Daikin Compressor JT125GABY1L
Copeland Compressor VR144KS-TFP-522
Danfoss Compressor MTZ19JA3VE
Toshiba Compressor PH260X2S-8KUC
Siemens Transformer TA623 629
Emerson Alco Expansion Valve TCLE-3HC
Siemens Contactor 3RA2325-8XB30-1BB4
ROYAL Fan TAF76D-6D
CPG Electric Motor CV1500-(15-30)S
LEEMIN Filter HX-250-100
Danfoss Sight Glass SGH 22S
HITACHI Capacitor 25V 560000UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ABB Circuit Breaker 10117999
Duelund Resistor CAST 3R9 ±5% 10W
Keyence Sensor LB-301
FLOJET Diaphragm Pump G257301
Daikin Air Conditioner RHXYQ40RSY1
Recent related posts
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/13/2020
How to deal with the high pressure overload of the chiller
When the condenser heat dissipation is poor, the compressor efficiency is low and the operating current increases. When the high pressure rises to 19Kg/cm2, the compressor trips under the protection of the high pressure switch and the compressor stops runPﰨ2
-
08/23/2022
Choose the Right Electric Valve Actuator
The actuator is an indispensable and important part of automatic control system. Its function is to accept the control signal sent by the controller and change the size of the controlled medium
-
08/25/2020
Renovation of the small turbine of the propylene refrigeration compressor oil station of the DCC unit has achieved initial results
Recently, the technicians of the DCC device have undergone transformation. The temperature of the small turbine bearing box of the propylene compressor oil station of the device has dropped from 90-120 degrees Celsius to 70-85 degrees Celsius
-
06/13/2020
The development history of magnetic levitation central air conditioning
Magnetic suspension centrifugal refrigeration compressors have been in research for 18 years from the beginning of z * to the present. At present, magnetic suspension refrigeration compressors have begun to be put into practical applications in large quan ﰸ2
-
08/19/2020
Installation and characteristics of cold storage air cooler
The cold storage air cooler is also known as an air cooler, which is an evaporative cooling and ventilation unit that integrates cooling, ventilation, dust prevention and deodorization.
-
03/07/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.
-
09/19/2022
How to Select a Hydraulic Pump
When choosing a hydraulic pump, the following aspects can be considered.
-
07/27/2020
The working principle of screw unit and common failure analysis
1. Refrigeration cycle and pressure enthalpy diagram<br></br> The refrigeration cycle of a screw chiller can be represented by a pressure-enthalpy diagram. The main state points are shown in the diagram, which will be used in the following discussion.
-
07/12/2020
Future trends of semi-hermetic screw compressors? Unseen companies may be eliminated2
Future trends of semi-hermetic screw compressors? Unseen companies may be eliminated From single-screw to single-machine two-stage, from ordinary type to frequency conversion, environmental protection, energy-saving type, from a single product to the provision of system solutions, the development of semi-hermetic screw compressors has never stopped and has continuously penetrated into major refrigeration projects.