There is no price at present, you can Request a Quote
We can also provide the following models
TLK 1.0 R22 MOP +10 °C 1/4" X 3/8"
TLK 1.0 R22 MOP ±0 °C 6mm X 10mm
TLK 1.0 R22 MOP ±0 °C 1/4" X 3/8"
For more information,please contact us freely
Honeywell Expansion Valve TLEX-e0543
There is no price at present, you can Request a Quote
People who bought this item also viewed
Danfoss Expansion Valve 068Z3348
Parker Sporlan Expansion Valve SA-K145
Danfoss Compressor MLT90CD
NORATEL Transformer SUL84B-460024
Fuji Contactor SC-0J
EVERFLOW Fan T125010SM
LIMING Electric Motor CM12-4-750-TJ
PARKER Filter G01286
Danfoss Sight Glass SGH 12S 014-0283
SAMWHA Capacitor 250V 470UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SHAKO Air Cylinder JC40B100-H
NKK Switch WT-21S
Omron Switch D4N-1B2HR
Recent related posts
-
09/10/2020
Air compressor lubricant performance requirements
1. High quality base oil The base oil of compressor oil can be divided into two categories: mineral oil type and synthetic oil type. The production of mineral oil-type compressor oil is generally obtained by solvent refining, solvent dewaxing, hydrogenation or clay supplement refining to obtain the base oil, and then add a variety of additives to blend.
-
07/23/2020
Share┃Causes and solutions for ice block, dirty block, and oil block
Foreword: The blockage of the refrigeration system is mainly caused by the ice blockage, dirty blockage or oil blockage of the capillary tube, or the dirty blockage of the dryer filter.
-
06/13/2020
Description of refrigeration compressor maintenance methods
Description of refrigeration compressor maintenance methods This article mainly describes the related content of the maintenance methods of refrigeration compressors
-
06/25/2020
Why does the use of cold and air conditioning in a car increase fuel consumption because the car cannot carry a compressor
Automotive air conditioning system _ compressor power is not high Knowledge point: The principle of the "refrigeration system" of automobile air conditioners is the same as that of domestic air conditioners. Both use compressors to drive refrigerants to achieve cooling by the principle of "evaporation and heat absorption".
-
06/24/2020
Reasons and solutions for refrigerator not cooling
Refrigerator non-refrigeration is a problem often encountered during the use of refrigerators. Refrigerator non-refrigeration always occurs suddenly. A large number of things that need to be refrigerated suddenly become unpredictable, which greatly affects daily life and wastes time to find.
-
03/14/2024
Difference between AC, DC and EC Fans
AC fans, DC fans and EC fans are classified according to their power supply type and motor type respectively. They differ in drive method, performance and application range.
-
06/19/2020
Structure diagram of single vane compressor_Main features of single vane compressor
The basic structure and working principle of single slide compressor.<img src="{{media url="Structure_diagram_of_single_vane_compressor_Main_features_of_single_vane_compressor.jpg"}}" alt="" /> Single sliding vane compressor is also called scraper compressor or rolling rotor compressor. Its structure is shown in Figure 3-7. A cylindrical eccentric rotor (also called a piston) is installed in the cylinder, and the center of rotation of the rotor coincides with the center of the cylinder. In the middle of the upper part of the cylinder, a scraper that can slide up and down is installed. Due to the force of the spring,<img src="{{media url="Structure_diagram_of_single_vane_compressor_Main_features_of_single_vane_compressor2.jpg"}}" alt="" />
-
03/09/2021
Servo driver related parameter setting method
Position feedforward gain: set the feedforward gain of the positioning loop. The larger the set value is, the smaller the position delay isand the larger the feedforward gain of the position loop is, the high-speed response of the control system will rise, but the position of the system is unstable and prone to oscillation. When high response characteristics are not required, this parameter is usually set to 0, indicating the range of 0 ~ 100%.
-
07/23/2020
FAQs about refrigeration compressors, do you know these?
Why control the impurity content and moisture content of the compressor and air conditioning system? Impurities entering the friction surface of the moving parts in the compressor pump body will cause abnormal scratches and wear. Impurities entering the solenoid valve, expansion valve, control valve, capillary tube and stop valve in the refrigerator system will block the valve hole or make the valve close tightly. And fail.
-
11/10/2021
Application of HMI in PLC Based Industrial Control System
Programmable logic controller (PLC) plays an important role in factory automation (FA). The continuous development of technology has greatly promoted the improvement of control function and control level of the control system based on PLC