Output function normally open
Sensing range [mm] 20...70
Housing cylindrical
Dimensions [mm] ? 100 / L = 40
Electrical data
Frequency AC [Hz] 47...63
Operating voltage [V] 90...250 AC
Protection class II
Reverse polarity protection no
Outputs
Output function normally open
Max. voltage drop switching output AC [V] 11
Minimum load current [mA] 15
Max. leakage current [mA] 6
Permanent current rating of switching output AC [mA] 200; (250 (...50 °C))
Short-time current rating of switching output [mA] 1500; (10 ms / 0,5 Hz)
Switching frequency AC [Hz] 5
Short-circuit proof no
Overload protection no
Detection zone
Sensing range [mm] 20...70
Sensing range adjustable yes
Factory setting sensing range [mm] 70
Real sensing range Sr [mm] 70 ± 10 %
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2
Hysteresis [% of Sr] < 15
Switch point drift [% of Sr] -15...15
Operating conditions
Ambient temperature [°C] -20...70
Protection IP 65
IFM Sensor I12003
People who bought this item also viewed
IFM Sensor IGS312
IFM Sensor PI1698
IFM Sensor IT5040
IFM Sensor PI2798
TAKEX Sensor DL-S7707
Contrinex Sensor DF-AD-601-C1735
Honeywell Sensor X211129PX2
Banner Sensor T30UIPAQ
Sailsors Transmitter A3-1.5kPa
Fireye Flame Detector 48PT2-1003
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TAKEX Sensor US-1AHPN
Nais Relay TXS2-LT-1.5V-1
Keystone Butterfly Valve FIGURE 320-125
Contrinex Sensor DW-LS-713-M12
SMC Solenoid Valve VQZ3121-1YZ1-02
Recent related posts
-
06/14/2020
Detailed introduction of common problems in the completion and acceptance steps of the intensive cabinet project
Detailed introduction of common problems in the completion and acceptance steps of the intensive cabinet project 1. Detection after assembly adjustment. After purchasing intensive cabinet products, consumers will first check. At this time, the test is 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈
-
09/16/2020
Quality Reliability Test and Improvement of the Main Body of Filter Element
Abstract: Combining with the actual situation of the oil production site, through a comprehensive analysis of the manifestations of filter element failure, the filter element material, main tube wall thickness, and water hole density are used as the three main reliability factors that affect the life of the filter element on-site, and the pole is reasonably determined.
-
01/29/2022
Refrigeration Compressor Frosting Reasons & Solutions
When we use the refrigeration compressor, there could be frosting. It’s a failure that we can solve.
-
09/27/2023
Industrial Water Chiller Repair: Troubleshooting and Maintenance Tips
An industrial water chiller is a critical component in many manufacturing and industrial processes. It is responsible for cooling various types of equipment, which helps to prevent overheating and maintain optimal performance.
-
07/31/2020
How should centralized air conditioners be used during epidemic prevention and control
Before using the centralized air-conditioning ventilation system, you should understand the type of the centralized air-conditioning ventilation system, the air supply range, and the air intake of the fresh air
-
06/20/2020
How does the air conditioner automatically control the indoor temperature, and how does the elevator achieve automatic operation
In the hot summer or cold winter, we all want to stay in a comfortable environment with a moderate temperature and low humidity, and the breeze is clean. <img src="{{media url="How_does_the_air_conditioner_automatically_control_the_indoor_temperature.jpg"}}" alt="" />The learning and working efficiency in this environment is very high. The air conditioner is an electrical appliance that can automatically adjust the indoor temperature, and it is becoming more and more popular.
-
08/17/2020
What is the reason for the excessive leakage of the refrigeration compressor
1. Insufficient oil flow, increase the oil supply appropriately; 2, the assembly sequence of the refrigeration compressor stuffing box is unreasonable and should be assembled according to the procedure;
-
07/19/2020
Centrifugal compressor unit
The machinery of each component in the mixture of liquid and liquid. The centrifugal refrigeration compressor is a rotary speed compressor, which is most suitable for compressing large-capacity gas or steam. The centrifugal chiller uses electricity as the power source.
-
06/21/2022
What is a Transformer?
A transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits.
-
08/24/2021
What Motors can be Used with VFD - Three-Phase Induction Motor
The ordinary three-phase asynchronous motor can be used with the variable frequency drive (VFD). Through the analysis of its main market share