Sensing range 0.5...30 mm non-flush mountable;
normally closed;
DC PNP;
M12 Connector;
IFM Sensor KG5301
People who bought this item also viewed
IFM Sensor IGS312
IFM Sensor IT5040
IFM Sensor PI2798
IFM Sensor PI1698
Keyence Sensor OP-87907
Contrinex Sensor DW-AS-643-M8-001
Honeywell Sensor T7560B1008
Banner Sensor SM31EMHSQDP
Danfoss Transmitter 063G1410
Honeywell Flame Detector C7027A1056
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Mitsubishi Servo Drive MR-J2-40C-S100
Omron PLC CJ1W-0C211
KAWASAKI Hydraulic Motor HPC080
HONTKO Encoder HPN-6D-1024-3-PP
Recent related posts
-
02/08/2023
What is a Blend Door Actuator?
Blend door actuators, also known as Heating, Ventilation, and Air Conditioning (HVAC) actuators, control the position of the vents and the air flowing into the passenger area of the vehicle.
-
08/14/2020
The layout principle of Freon refrigerant pipeline
The main feature of Freon refrigerant is that it dissolves with the lubricating oil. Therefore, it must be ensured that the lubricating oil from each refrigeration compressor can return to the refrigeration compressor after passing through the condenser,
-
06/13/2020
The role of lubricating oil
The role of lubricating oil 1) A dynamic seal is formed between the screw and the compression chamber and the male and female screws to reduce the leakage of refrigerant from the high-pressure side to the low-pressure side during the compression process.
-
09/18/2021
Analysis of Refrigerant Prices Rising
Refrigerant is a compound that usually exists in a liquid or gaseous state. It easily absorbs heat from the environment
-
08/31/2021
What is Adobe Media Encoder?
Adobe Media Encoder is an application that allows you to encode audio and video files in a variety of distribution formats for different applications and audiences.
-
09/01/2020
Dr. Zhang Xuefeng, Executive Director of Sigatobo Battery Air Compressor, accepted an exclusive interview with Gaogong Hydrogen!
Gaogong Hydrogen Electric: Established in 2011, Sigatobo has 8 years of product research and development experience and deep market knowledge. What are the core technologies of the company's hydrogen fuel cell air compressor?
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/05/2020
Where does the air compressor rental market go
At the beginning of 2017, Dr. Li in the construction industry said that the international sales of construction machinery hours to leasers have reached more than 25% of the total machinery output value,
-
04/23/2023
How Refrigerator Compressor Works (Structure Diagram, Working Principle Diagram)
For a refrigerator product, the most core part is the compressor. If the refrigerator does not have a compressor with good quality and technology
-
09/18/2020
The current sales model of air compressors
1. Head office→regional agent→distributor→salesman→customer (representing company: Fusheng, Atlas, etc.) ⑴. It takes about four stages to reach the customer, and the profit is also reduced considerably (because the intervention of the middleman increases the cost)