Maximum output voltage and current are up to 150V and 60A respectively
Maximum output power of single channel up to 1200W, in configuration of
Output voltage 80V and output current 60A (IT6512, IT6512A)
Output voltage 150V and output current 30A (IT6513, IT6513A)
High output voltage and current resolution
1mV/1mA (IT6502D, IT6512, IT6512A)
3mV/1mA (IT6513, IT6513A)
High output voltage and current accuracy
< = 0.02percent + 30mV/< = 0.1percent + 1percentFS (IT6502D, IT6512, IT6512A)
< = 0.05percent + 30mV/< 2percent + 0.1percentFS (IT6513, IT6513A)
High voltage and current readback resolution
1mV/1mA (IT6502D, IT6512, IT6512A)
3mV/1mA (IT6513, IT6513A)
High output voltage and current readback accuracy
< = 0.02percent + 30mV/< = 0.1percent + 1percentFS (IT6502D, IT6512, IT6512A)
< = 0.05percent + 30mV/< 2percent + 0.1percentFS (IT6513, IT6513A)
Load regulation
< 0.01percent + 8mV/< = 1percent + 10mA (IT6502D)
< 0.01percent + 8mV/< 0.1percent + 10mA (IT6512, IT6512A)
< 0.05percent + 30mV/< 0.1percent + 30mA (IT6513, IT6513A)
Line regulation
< 0.02percent + 2mV/< 0.02percent + 2mA (IT6502D, IT6512, IT6512A)
< 0.02percent + 20mV/< 0.02percent + 10mA (IT6513, IT6513A)
Low ripples/low noise (20Hz-20MHz)
< = 30mVp-p (IT6502D)
< 30mVp-p (IT6512, IT6512A)
< 60mVp-p (IT6513, IT6513A)
Power source: CV/CC modes
Convenient data entry via knob or numerical key pad
Can use the knob to adjust voltage and current
Can adjust the numbers steps using the cursor
Adjustable rising and falling time. No matter it is under the power supply mode (CV, CC), the IT6500E Series support independent adjustable rise/fall time setting in different modes, and the setting up range is 1ms-24h
Output programmed voltage and current
Support parallel function, automatic even current distribution
List mode: Capable output wave based on edit voltage/current with time variations
Remote sense: The remote sense interface to compensate line voltage, increase output accuracy
Protection functions
Power source: OVP, OCP, OPP, OTP
Turn-off protection
Under voltage protection
Sense compensate voltage: < = 2V
Isolation (output to ground): 300V
Memory capacity: 100 groups, for save and recall
Built-in DIN 40839 and ISO-16750-2 standard voltage curves for automobile power net (IT6512, IT6513)
Intelligent fan control, energy conservation and noise reduction
Versatile interface
RS232, RS485, USB and GPIB come as standard for all models
External 0-10V Analog Control Interface (IT6502D, IT6512A, IT6513A)
ITECH Power Supply IT6512A
People who bought this item also viewed
Fanuc Power Supply IC697PWR711
Baldor Servo Motor SSBSM80C-175CA
Parker Servo Drive MPA-75-460
Endress Hauser Transmitter CPM253-MR8105
Panasonic PLC AFPX-EC08
Sanyo Denki Fan 109R0605M4D01
Oriental Motor Electric Motor PKE596AC-HS50
INFINEON IGBT Module BSM300GAR120DLC
SAWANA Relay ASY-3SM AC110V 999M
PHILIPS Battery Junying 18292
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PARKER Hydraulic Motor PGM502A0079
AirTAC Air Cylinder ACE16X40
SIEMENS Capacitor B41456-B9339-M
Recent related posts
-
09/05/2020
The role of air compressor air filter and the hazards of overdue use
The air compressor air filter (also known as style) is composed of an air filter assembly and a filter element. The outside is connected to the air compressor's intake valve through a joint and a threaded tube to filter the dust, particles and other impurities in the air.
-
06/24/2020
Why is the air conditioner not cooling
1.Check whether the compressor is working normally. If the compressor is broken, the air conditioner cannot start normally and there will be no cooling effect. 2. There is not enough refrigerant in the air conditioner. At this time, you need to add Freon, and the time for adding Freon can be very long. 3. The air conditioner itself has quality problems and the electrical components have failed. In this case, you need to find a master to repair it.
-
07/19/2020
The function and working principle of oil separator
The role of the oil separator in the chiller; In the vapor compression refrigeration system, the compressed ammonia vapor (or freon vapor) is in a high-pressure and high-temperature superheated state. Because of its fast flow rate and high temperature when it is discharged. Part of the lubricating oil on the cylinder wall is inevitably
-
07/07/2020
The aging of air conditioners caused fires. The heat is coming.
The aging of air conditioners caused fires. The heat is coming. Are your home appliances overaged? The police reminded: As summer is approaching, we should pay attention to the service life, quality and installation environment of household appliances. The wires of many electrical appliances are mainly insulated by a layer of rubber on the outside.
-
07/05/2020
Notes on long-term shutdown of Hitachi air compressors during long holidays
Notes on long-term shutdown of Hitachi air compressors during long holidays Thank you very much for your strong support for Hitachi Air Compressor sales and after-sales service!
-
09/14/2020
Application of oil bath air filter in air compressor industry
Cement plants have many production and grinding processes, and the ambient air contains high dust concentrations. The original design of dust removal filter device used in air compressor is mostly paper filter element dust removal.
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser
-
09/02/2020
There are 8 reasons for the high fuel consumption of air compressors, some of which can't be thought of!
Run oil In our daily work, we often encounter the problem of air compressor running oil. In addition to the quality of the oil itself, what other reasons can cause the running oil? In practice, engineers have summed up several reasons that can cause oil running. Let's share with you.
-
03/17/2021
Several effective tips for servo motor drive repair
1. When the Panasonic digital AC servo system is powered on, the motor vibrates and makes a lot of noise, and then the driver gives an alarm No. 16, what should I do?
-
06/27/2020
Refrigerator compressor working principle, wiring diagram, structure
The core component of the refrigerator is the compressor. If there is no compressor with good quality and technology, it is not a good refrigerator. At present, many products on the market advertise the use of high-quality compressors, so which compressor brands are in China, and which failures are prone to occur? I will introduce you one by one in the following!