FEATURES:
Nodular cast iron body
KVS 0.4...350
2-way PDTC (normally open), 3-way mixing and 3-way diverting configurations
Fluid temperature 2...200°C, with glycerin cup: -20...200°C, with cooling fins: up to 280°C
DIN Flanged
ORDERING INFORMATION
2-WAY PDTC (NORMALLY OPEN) CONFIGURATION
CODES * |
BODY SIZE |
KVS |
CLOSE-OFF PRESSURE kPa |
|||||||
FA-2000-741x 2200 N |
FA-2000-751x 2400 N |
FA-3300-741x 6000 N |
RA-3000-732x 3000 N |
RA-3100-8226 1700 N |
VA1x20 ** 2000 N |
VA1125 ** 500 N |
VA78xx 1000 N |
|||
VG82A4S1H |
DN15 |
1.0 |
--- |
--- |
--- |
--- |
--- |
2500 |
2500 |
2500 |
VG82A3S1H |
1.6 |
|||||||||
VG82A2S1H |
2.5 |
|||||||||
VG82A1S1H |
4.0 |
|||||||||
VG82B1S1H |
DN20 |
6.3 |
2030 |
|||||||
VG82C1S1H |
DN25 |
10 |
1360 |
|||||||
VG82D1S1H |
DN32 |
16 |
660 |
|||||||
VG82E1S1H |
DN40 |
25 |
1550 |
2000 |
370 |
|||||
VG82F1S1H |
DN50 |
40 |
920 |
1300 |
600 |
750 |
1020 |
--- |
||
VG82G1S1H |
DN65 |
63 |
710 |
1010 |
450 |
580 |
750 |
|||
VG82H1S1H |
DN80 |
100 |
330 |
480 |
200 |
260 |
370 |
|||
VG82J1S1H |
DN100 |
160 |
180 |
--- |
720 |
290 |
100 |
140 |
210 |
|
VG82K1S1H |
DN125 |
250 |
100 |
450 |
170 |
--- |
80 |
120 |
||
VG82L1S1H |
DN150 |
350 |
50 |
270 |
100 |
40 |
70 |
ORDERING INFORMATION
2-WAY MIXING CONFIGURATION
CODES * |
BODY SIZE |
KVS |
CLOSE-OFF PRESSURE kPa |
|||||||
FA-2000-741x 2200 N |
FA-2000-751x 2400 N |
FA-3300-741x 6000 N |
RA-3000-732x 3000 N |
RA-3100-8226 1700 N |
VA1x20 ** 2000 N |
VA1125 ** 500 N |
VA78xx 1000 N |
|||
VG88A4S1H |
DN15 |
1.0 |
--- |
--- |
--- |
--- |
--- |
2500 |
2500 |
2500 |
VG88A3S1H |
1.6 |
|||||||||
VG88A2S1H |
2.5 |
|||||||||
VG88A1S1H |
4.0 |
|||||||||
VG88B1S1H |
DN20 |
6.3 |
2030 |
|||||||
VG88C1S1H |
DN25 |
10 |
1360 |
|||||||
VG88D1S1H |
DN32 |
16 |
660 |
|||||||
VG88E1S1H |
DN40 |
25 |
1550 |
2000 |
370 |
|||||
VG88F1S1H |
DN50 |
40 |
920 |
1300 |
600 |
750 |
1020 |
--- |
||
VG88G1S1H |
DN65 |
63 |
710 |
1010 |
450 |
580 |
750 |
|||
VG88H1S1H |
DN80 |
100 |
330 |
480 |
200 |
260 |
370 |
|||
VG88J1S1H |
DN100 |
160 |
180 |
--- |
720 |
290 |
100 |
140 |
210 |
|
VG88K1S1H |
DN125 |
250 |
100 |
450 |
170 |
--- |
80 |
120 |
||
VG88L1S1H |
DN150 |
350 |
50 |
270 |
100 |
40 |
70 |
3-WAY DIVERTING CONFIGURATION
CODES * |
BODY SIZE |
KVS |
CLOSE-OFF PRESSURE kPa |
|||||||
FA-2000-741x 2200 N |
FA-2000-751x 2400 N |
FA-3300-741x 6000 N |
RA-3000-732x 3000 N |
RA-3100-8226 1700 N |
VA1x20 ** 2000 N |
VA1125 ** 500 N |
VA78xx 1000 N |
|||
VG89A4S1H |
DN15 |
1.0 |
--- |
--- |
--- |
--- |
--- |
2500 |
2500 |
2500 |
VG89A3S1H |
1.6 |
|||||||||
VG89A2S1H |
2.5 |
|||||||||
VG89A1S1H |
4.0 |
|||||||||
VG89B1S1H |
DN20 |
6.3 |
2030 |
|||||||
VG89C1S1H |
DN25 |
10 |
1360 |
|||||||
VG89D1S1H |
DN32 |
16 |
660 |
|||||||
VG89E1S1H |
DN40 |
25 |
1550 |
2000 |
370 |
|||||
VG89F1S1H |
DN50 |
40 |
920 |
1300 |
600 |
750 |
1020 |
--- |
||
VG89G1S1H |
DN65 |
63 |
710 |
1010 |
450 |
580 |
750 |
|||
VG89H1S1H |
DN80 |
100 |
330 |
480 |
200 |
260 |
370 |
|||
VG89J1S1H |
DN100 |
160 |
180 |
--- |
720 |
290 |
100 |
140 |
210 |
|
VG89K1S1H |
DN125 |
250 |
100 |
450 |
170 |
--- |
80 |
120 |
||
VG89L1S1H |
DN150 |
350 |
50 |
270 |
100 |
40 |
70 |
Johnson Controls Actuator FA-3340-7416
People who bought this item also viewed
Johnson Controls Actuator VA301BDC-C
Johnson Controls Actuator M9116-AGA-2
Johnson Controls Actuator VA-7152-1001
Honeywell Actuator MVN7234
Johnson Controls Actuator M9106-AGA-2
Johnson Controls Actuator VA9109-IGA-4
MINDMAN Air Cylinder MCJQ-11-100-5M
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ABB Circuit Breaker T4S250 DC TMA250 FFCL 4P
MINDMAN Air Cylinder MCJQ2-12-12-45
Danfoss Transmitter 060G1401
Recent related posts
-
07/11/2022
Differences between Single Mechanical Seals and Double Mechanical Seals
Pumps work hard to distribute fluid throughout elaborate systems. As a failsafe against leakage, pumps include one of two parts: packings or mechanical seals.
-
07/18/2020
reasons why the constant temperature and humidity test chamber does not cool
1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil damage the suction valve plate when the gas is sucked into the cylinder of the compressor, and it is produced when the piston is compressed when the piston is close to the top dead center and is not quickly discharged during the exhaust process after entering the cylinder.
-
09/04/2020
In the nitrogen generator system, are the gas storage tanks and refrigeration dryers necessary equipment
Users often ask about nitrogen generators. After some understanding and communication, I asked users, if you buy a nitrogen generator, how big is the gas storage tank?
-
01/05/2022
Variable Speed Compressor in Refrigerator
The differences between variable speed compressor and fixed speed compressor are their working principle and user experience.
-
04/20/2022
Six Level Measuring Instruments and Relative Merits?
Float level meter is an instrument of measuring liquid level based on buoyancy principle. Usually, the combination of floating ball and scale enables the observer to intuitively read the height of liquid level.
-
01/02/2021
Mads Clausen - the founder of Danfoss
From just a single valve and an unquenchable desire to succeed, Danfoss founder, Mads Clausen, created a global business that still sets the standard for innovation today.
-
07/04/2020
Introduction of the models such as the MT-100 and other hermetic compressors
Introduction of the models such as the MT-100 and other hermetic compressors The picture shows the fully enclosed compressor MT-100, which is installed by the customer. Meiyou Le Maneurop hermetic compressor detailed introduction;
-
06/17/2020
The performance of the refrigerator compressor is broken
The performance of the refrigerator compressor is broken The refrigerator compressor is the heart of the refrigerator and the core component of the refrigerator. If the refrigerator compressor does not work, the entire refrigerator will not run. So why 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋ
-
08/14/2020
Reasons for internal protection of industrial chiller compressors
There is a thermal switch inside some compressors. The function of this switch is to disconnect the power supply line to the compressor motor when the temperature of the compressor exceeds the set value.
-
09/15/2020
Micro vacuum pump, micro air pump selection instructions
With the vigorous development of the instrumentation industry, miniature vacuum pumps and miniature air pumps that are compact, oil-free and environmentally friendly have become more and more widely used. How can we choose the most appropriate product among a wide range of micropumps?