KEMET Capacitor 16V 10UF
People who bought this item also viewed
COSEL Power Supply LEP150F-24-S
ORION Fan OD8020-24HB02A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MINDMAN Air Cylinder MCMI-11-20-500
HONGFA Relay HFE20-1-5-1HST-L2
YUKEN Piston Pump A90-LR04CS-60
KOMPASS Piston Pump V23-23A1R10X
Recent related posts
-
09/11/2023
Exploring the Different Types of Heat Pumps: A Comprehensive Guide
Heat pumps are an excellent source of heating and cooling for homes and businesses, offering energy efficiency, comfort, and convenience. They are available in a variety of types, each with their own advantages and disadvantages.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
10/16/2023
Cold Storage Warehouse: Everything You Need to Know
With the increasing demand for fresh food products, the need for proper storage and preservation has become more important than ever.
-
02/24/2023
The Differences Between Butterfly Valve and Ball Valve
The biggest difference between butterfly valve and ball valve is that the opening and closing part of butterfly valve is a plate, while the ball valve is a ball.
-
08/11/2023
How Does a Heat Pump Work in Winter?
Heat pumps are an excellent alternative to traditional heating systems, particularly in areas with mild winters. Unlike traditional heating systems that rely on burning fuel or electricity to generate heat
-
08/15/2020
The correct operation method of air-cooled refrigerator
For companies that use air-cooled refrigerators, the stable use of equipment is the most important thing, and if you don’t pay much attention during use, it will cause problems with the stability of the equipment due to some external factors.
-
06/22/2020
Working principle of steam compressor_steam compressor application
Working principle of steam compressor_steam compressor application Working principle of steam compressor After the steam is filtered by the filter, clean steam then enters the host cavity through the intake valve, and the volume of the cavity changes from large to small to compress the steam. The volume of the cavity is changed by the rotor rotating under the drive of the motor. <img src="{{media url="Working_principle_of_steam_compressor_steam_compressor_application.jpg"}}" alt="" />
-
09/04/2020
Eight core issues warn compressor companies, and the rapid changes in the market cannot be ignored
When we find that the hot companies a few years ago have become traditional enterprises, you will understand how fast we are in an era of change! Most compressor companies now have a very serious sense of crisis-dealers are difficult to manage
-
07/22/2020
Safety Operating Regulations for Freon Refrigeration Compressor Unit
Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
06/25/2020
What are the three tubes of the refrigerator compressor
What are the three tubes of the refrigerator compressor 1. The general refrigerator compressor has three pipe ports;