There is no price at present, you can Request a Quote
Current:7.2A
Power:1635W
Volume flow:210L/min
Starting pressure:0.5Mpa
Rated exhaust pressure:0.8Mpa
Gas tank volume:90L
Noise:68-72dB
Packing size:105*47*78cm(carton packaging)
KEYOUNG Air Compressor KY-A014
There is no price at present, you can Request a Quote
People who bought this item also viewed
SMC Proportional Valve ITV3050-044L5
Omron PLC CS1D-II102D
Lovato Contactor BGT0910A
AirTac Fuel Water Separator GAC400-15S
DUNGS Safety Valve ZRDLE415/5
CKD Filter F3-550570
Schneider Relay RSB2A080B7
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ABB Circuit Breaker 10133783
Mitsubishi Compressor SNB220FBGMT
SCHMERSAL Switch UV9H432Y
SMC Solenoid Valve SZ3260R-5LOZ-C4
AirTAC Air Cylinder MAD16X100S
Recent related posts
-
06/14/2020
How to protect the refrigeration compressor, you must master the following knowledge
When the compressor is running, some abnormal conditions may occur, such as: the discharge pressure is too high, the suction pressure is too low, the oil pressure is insufficient, the motor is overheated, and excessive liquid enters the cylinder. If an ab 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
06/23/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
01/19/2023
Choose the Right Solenoid Valve
Solenoid valves are industrial equipment controlled by solenoids. It is the basic element of automation used to control fluids.
-
09/10/2020
About the role of screw air compressor inverse proportional valve
The inverse ratio valve is used in conjunction with the disc air intake control. When the system pressure increases due to the decrease in air consumption and reaches the set pressure of the inverse ratio valve, the inverse ratio valve acts and reduces the control air output.
-
06/28/2020
One article to understand what is a piston compressor
One article to understand what is a piston compressor Piston compressor is a compressor that relies on live cold reciprocating motion to pressurize gas and deliver gas. It belongs to positive displacement compressor, also known as "reciprocating piston compressor" or "reciprocating compressor".
-
06/30/2022
Types of Check Valve
Depending on the design of the check valve, they will operate slightly differently. The most common check valve is a spring loaded in-line check valve, however, we will discuss multiple types below.
-
03/15/2021
What are the advantages of CDHD2 high-performance servo drive?
What are the characteristics of CDHD2 high-performance servo drive? What are the advantages of CDHD2 high-performance servo drive?
-
08/20/2020
The role of pressure relay in refrigeration system
In industrial refrigeration, a pressure relay is an electric switch controlled by a pressure signal. It is often used as a protection and regulating element that directly controls the start and stop of the refrigeration compressor or controls the opening and closing of certain solenoid valves
-
06/14/2020
Global Compressor for Refrigerator Market Overview, Development History and Forecast to 2026 shared in Latest Research
he global Compressor for Refrigerator market is valued at xx million US$ in 2020 is expected to reach xx million US$ by the end of 2026, growing at a CAGR of xx% during 2021-2026.
-
09/14/2020
Large oil consumption of the unit or high oil content of compressed air
The amount of lubricating oil is too much. The correct position should be observed when the unit is loaded. At this time, the oil level should not be higher than half;