Trip class 10A
Bimetallic style
LG LS Relay GTH-22 0.25-0.4A
People who bought this item also viewed
JEL Relay S1C-225WDV
TOGAMI Relay TJ-125-3F
SIEMENS Relay 3TK2824-1AL20
Block Transformer VC 3,2/1/6
Siemens Circuit Breaker 3RV1042-4HA10
Eaton Contactor DILM32-01C
Ferraz Shawmut Fuse PC72GB69V250EF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder TACE20X5
CHINT Fuse HDLRT0-200 200A
Recent related posts
-
09/06/2020
Application of synthetic compressor oil
At present, synthetic lubricants are widely used in the compressor field. Among them, oil-injected and oil-immersed rotary screw air compressors and large reciprocating compressors are one of the most used markets. For example, the sales volume of synthetic compressor oil in Western Europe was 6000t in the late 1980s, and it rose to 10000 in the early 1990s. The sales volume in the United States has exceeded 15,000 tons, and it is increasing at a rate of more than 10% per year.
-
05/06/2023
How Water Source Heat Pumps Work
A heat pump is a device that transfers thermal energy from a low-grade heat source to a high-grade heat source. Heat pumps, driven by electricity, usually first obtain low-grade heat energy from natural air, water or soil, and then provide high-grade heat energy.
-
09/06/2020
What are the requirements of modern industry for oil-free air compressors
After the air is mechanically compressed, it becomes compressed air. The equipment used to produce compressed air is usually called an air compressor. Compressed air is an indispensable pneumatic energy source in people's production and life.
-
08/04/2022
Differences Between Overflow Valve and Pressure Relief Valve
Overflow valve is to prevent system overload and ensure safety. The pressure relief valve reduces the system pressure on the premise that the system is not overloaded.
-
06/14/2020
Disposal method of ammonia leakage accident of ammonia refrigeration compressor
On 2020.2.8, a batch of much-needed protective materials donated by Danfoss and Abena, a world-renowned health care product manufacturer, will be sent from Denmark to China to support China's fight against new coronary pneumonia. The total price of this b 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֜ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/08/2020
Advantages and disadvantages of closed motor and open motor of air compressor
Air compressor enclosed motor: Protection grade: IP44, IP54, IP55 Advantages: 1) Wide application range. The air compressor driven by a closed motor can be used in places with poor environment. For example, there is a lot of dust and the fibers are flying. Factories and mining industries with corrosive gas and other surrounding areas.
-
11/30/2021
Differences Between Sensor and Transmitter
Sensors and transmitters play an important role in the field of automatic control. Transmitters are developed based on sensors, which have close relationship and differences.
-
09/14/2020
What is the difference between oil and oil-free air compressors
The oil and non-oil in the air compressor generally refer to the oil content of the exhaust gas of the air compressor. Generally, the oil content of the oil machine is larger, and the oil content of the oil-free machine is 0.01ppm,
-
07/27/2020
Most high and low temperature test chambers choose Taikang compressors
The refrigeration compressor of the high and low temperature test chamber adopts the original French Tecumseh compressor. Its working principle is to suck in low temperature and low pressure refrigerant gas from the suction pipe, drive the piston to compress it through the operation of the motor
-
07/31/2020
What kind of equipment is suitable for high and low pressure refrigerant charging method
There are generally two types of refrigerant charging methods: low-pressure charging and high-pressure charging. The advantage of the low pressure charging method is that it is easier to control the amount of refrigerant charged,