Medium: Air
Code 11: Double acting / Male thread
Operating pressure range: 0.05-1 MPa
Proof pressure: 1.5 MPa
Ambient temperature: -5 degrees-+60 degrees(No freezing)
Available speed range: 50-500 mm/sec
Sensor switch: RCA
Sensor switch holder: HV1, HV2, HV3
MINDMAN Air Cylinder MCQV2-11-125-20
People who bought this item also viewed
Festo Air Cylinder DGP-32-600-PPV-A-B-KH-GK
Festo Air Cylinder DGC-18-450-KF-PPV-A
CKD Air Cylinder SCPG2-M-00-10-30
CKD Air Cylinder STSB-4010
MINDMAN Air Cylinder MCJQ-11-25-40M
MINDMAN Air Cylinder MCJQ-11-16-30
SHAKO Air Cylinder JC32B05
Festo Air Cylinder DPZ-10-25-P-A-KF
Festo Air Cylinder DNU-80-200-PPV-A
HENGSTLER Encoder RI58-O/300EK.42KD
TPC Solenoid Valve DS6240-2DZ-06
SIEMENS Actuator GDB331.2E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Chint Circuit Breaker DZ15-40/3902T
THK Linear Guideway HSR45LA1SS
MINDMAN Air Cylinder MCMA-21-20-50
KCL Vane Pump KT6E-062-1R00-B4
AEG Circuit Breaker MCC169S4125
Fuji Circuit Breaker EW63SAG-3P63A
Recent related posts
-
08/08/2020
What kinds of systems are there for central air conditioning Which is better for home installation
What kinds of systems are there for central air conditioning Which is better for home installation For owners who want to decorate their new home, air conditioning may be an essential part of building a comfortable home.
-
08/14/2020
Low-voltage alarm and fault repair methods for precision air conditioners in computer rooms
The low-pressure alarm for the special air conditioner in the data center computer room is a problem we often encounter in daily maintenance. Especially often encountered in winter.
-
07/20/2020
Six aspects of repair and maintenance of refrigeration compressors in cold storage
A. During the initial operation of the cold storage unit, carefully observe the oil return of the compressor and keep it clean. If you find that the oil level is not clean enough or if the oil level drops, you should add oil or replace it with new oil in time. This can avoid poor lubrication
-
08/02/2020
How to use refrigerant to empty the air conditioner after installation
Air, moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage.
-
06/29/2020
The core problem of compressor operation
The core problem of compressor operation The scroll compressor is a volumetric compression compressor, and the compression component is composed of a movable scroll and a static scroll. Its working principle is to use the relative orbital motion of the movable and static scrolls to form a continuous change in the enclosed volume, so as to achieve the purpose of compressing gas.
-
06/14/2020
Special program for Trane screw machine RTHA RTHB RTHC RTHD
Special program for Trane screw machine RTHA RTHB RTHC RTHD 1.Increase the maximum operating load limit of the unit; 2.Increase the protection resistance output; 3.Increase the refrigerant temperature protection; 4.Increase the oil temperature so ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džቜ먢䇨珵呈ᠾ뤂ᐱ ⬿먲僧ᐱ靖㥲ᐲ�僬㣢ᐲ ᠾ 靖랖僧Ѽ ﯼ靖 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ ﯼ
-
06/21/2020
Common system failures of refrigeration equipment
Common system failures of refrigeration equipment 1. Liquid return: For refrigeration systems using expansion valves, liquid return is closely related to the selection and use of expansion valves. Expansion valve selection is too large, the superheat setting is too small, the installation method of the temperature sensor is incorrect, the insulation bandage is damaged, and the expansion valve failure may cause liquid return.<img src="{{media url="Common_system_failures_of_refrigeration_equipment2.png"}}" alt="" />
-
07/25/2020
How to distinguish the quality of the wire?
Good strong wires are the basic level of home circuit engineering, so how do consumers judge which strong wires are good wires?
-
07/27/2020
What is the principle of air conditioning refrigeration system? What is the heating principle of the air conditioner?
When we use the air conditioner, the commonly used function should be the cooling function, because the cooling function can bring us a more comfortable and cool environment in summer, but we all have these principles about how the air conditioner is cooled.
-
07/08/2020
How to solve the problem of poor oil return of screw chiller
1. What is the cause of the poor oil return of the screw chiller? Generally speaking, the reason for the poor oil return of the screw chiller is mainly due to the phenomenon of the gas mixture of lubricating oil and refrigerant during the operation. Specifically, in the operation of the refrigeration system, encountering the miscibility of the refrigerant and the refrigerator lubricating oil will cause the lubricant in the refrigeration compressor to run and the refrigerant will be discharged into the condenser in the form of gas mist and droplets.