Adding fluoride to the air conditioner is tricky, don't be fooled!
remind
In the hot weather, many citizens have begun to use air conditioners to remind everyone to be careful not to be fooled by unnecessary "air conditioner filling".
event
Ms. Liu said that a few days ago, there was a problem with an air conditioner at home. Because the warranty period expired, she found an air conditioner repairer online.
"After inspection, it was found that the air conditioner lacked fluoride and needed to be filled with liquid. It was said that each pressure was 4 $." Ms. Liu said that she didn't quite understand how to charge by pressure.
"4 sets of 1.5P each add 10 pressures, a total of 400$ , and 3P cabinets add 12 pressures (the other side of the cabinet will charge 50 yuan for each pressure) for a total of 120 $." Ms. Liu said. 5 air conditioners added fluoride plus 550$.
Event analysis
1. At present, the fixed-frequency air conditioner with the old refrigerant R22 as the refrigerant is the fixed-frequency air conditioner on the market that needs more maintenance. "The operating pressure is 0.49Mpa, and one unit can have at most 5 pressures. How can I charge for 10 units."
2. It is unreasonable to charge for the pressure value of the pressure gauge. There are many factors such as pressure and temperature, which can only indicate whether liquid is needed to be added, and cannot represent the amount of liquid added.
3. A 1.5P air conditioner requires 0.9 to 1.2 kilograms of refrigerant (the public can see the "refrigerant filling amount" mark on the outside of the air conditioner), and the maximum is 1 kilogram. The price of 1 kilogram of R22 refrigerant on the market is 30 yuan, plus maintenance fees, etc., generally the normal charge is 30 to 50 $.
4. The air conditioner "even after more than ten years of use, as long as it is installed in place and the seal is in good condition, there is no need to add liquid. Unless it is not in place when installed, it may be short of liquid and only use a small amount of liquid. Of course, there is also leakage However, the air conditioner will not operate normally, and it will be necessary to find the leakage point and repair it.
After analysis, it can be determined that Ms. Liu was fooled, and the maintenance cost of several hundred yuan was increased to more than two thousand. There are still a lot of tricks in air-conditioning repairs, and the editor behind will slowly analyze it with everyone.
This editor reminds everyone to pay attention:
To repair the air conditioner, find a qualified and regular repair company or repair shop, and pay attention to the ticket request. Regular home appliance repair merchants have the Municipal Bureau of Commerce.
Adding fluoride to the air conditioner is tricky, don't be fooled!
Recent related posts
-
07/29/2020
Adding fluoride to the air conditioner is tricky, don't be fooled!
remind<br></br> In the hot weather, many citizens have begun to use air conditioners to remind everyone to be careful not to be fooled by unnecessary "air conditioner filling
-
07/29/2020
Common sense of wire and cable calculation
What is the maximum current and power that a square wire can pass? How much wire is used for 100KW of electricity for project construction? Large wires cause waste, and small wires have more serious consequences. Here I share with you my estimation experience.
-
07/29/2020
Pressure controller use and adjustment
Many pressure controllers are used in the refrigeration system, and the pressure is controlled by the on and off of the contacts. Mainly include high pressure pressure controller, low pressure pressure controller, high and low pressure pressure controller, pressure difference controller and oil pressure protection pressure controller.
-
07/29/2020
What to do if the air-conditioning copper pipe leaks
What should I do if the air-conditioning copper pipe leaks? Why is the air-conditioning copper pipe leaking? Everyone is familiar with copper pipes for air conditioning.
-
07/29/2020
Nine refrigerant leakage locations and solutions
There are many welds on the left and right sides of the evaporator, and there may be more leaks. The leak of the newly installed air conditioner is mainly due to the poor welding skills of the employees of the air conditioner manufacturer.
-
07/28/2020
Analysis of common failure causes of hermetic refrigeration compressors
. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.
-
07/28/2020
Method and steps to replace the refrigeration compressor
Cut off the power supply: Before replacing the compressor, be sure to cut off the power supply of the unit, otherwise there will be a risk of electric shock.
-
07/28/2020
How much does it cost to install a 120㎡ central air conditioner? What is the standard installation process?
Nowadays, central air-conditioning has lifted the veil of mystery and has begun to enter thousands of homes, and it has gradually become a trend.
-
07/28/2020
Refrigeration common fault terms and operation precautions
Frozen blocking: also known as "ice blocking". The phenomenon in which liquid freezing substances [such as ice] hinder the flow of refrigerant in the Freon refrigeration system. Often occurs in throttling mechanisms.
-
07/28/2020
Air-conditioning animation, wind system and water system can be understood at a glance!
Air-conditioning animation, wind system and water system can be understood at a glance! First, let's take a few professional and traditional central air conditioning systems 1.Water cooling unit +AHU/FCU
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
NAGANO KEIKI Transmitter ZT60 (0-300kPa)
AirTAC Air Cylinder TCMJ80X250-40S
CKD Air Cylinder SSD2-L-16D-20-N-W1