Air compressor inverter will overheat The reasons and measures are here
The high temperature in summer often causes high temperature failure of the air compressor. At the same time, for the air pressure of the frequency conversion control, it is easy to cause the high temperature problem of the air compressor frequency converter. The high temperature problem of the inverter will not only affect its normal performance, but also affect its service life.
If the inverter fails, it will also affect the operation of the entire air compressor system. Ai Gao summarized the common causes and solutions for the overheating of the air compressor inverter.
The ambient temperature is too high
If the ambient temperature is too high, the temperature of the internal components of the inverter will be too high. To protect the internal circuit of the inverter, the inverter will alarm and stop.
To reduce the temperature of the use environment, a fan can be installed or the ground can be washed with water.
Poor ventilation
If the air duct of the inverter is blocked or the air duct of the control cabinet is blocked, it will affect the internal heat dissipation of the inverter and cause the inverter to overheat and alarm.
Regularly check and repair the inverter, remove the garbage in the air duct, and smooth the air duct.
The cooling fan is blocked or damaged
When the cooling fan of the inverter does not work normally, a large amount of heat will accumulate in the inverter and cannot be dissipated.
Overhaul the cooling fan of the inverter and replace it if it is damaged.
overloaded
When the load carried by the inverter is too heavy, it will generate excessive current and generate a lot of heat. Sometimes the inverter will overheat and alarm.
Reduce the load or increase the capacity of the inverter.

Related Info
Air technology-the development of the gas industry 10 reasons why the compressor industry should participate in foreign exhibitions Advantages and applications of cast copper rotors in high-efficiency motor remanufacturing Advantages of frequency converter air compressor Advantages of permanent magnet variable frequency screw air compressorAir compressor inverter will overheat The reasons and measures are here
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Fuji VFD Frequency Converter FRN2.2F1H-2A122
Contact Us
Siemens Transmitter 7MF4433-1FA62-1NC1-Z
Contact Us
Yaskawa Servo Motor SGM-01B512
US$427.31
Mitsubishi Compressor AHV60FBET
US$985.92
GSWC Bearing 6208-HT1
Contact Us
Sanyo Denki Fan 9WL0824P4G001
US$72.82