Correct operation method and precautions of distribution box during cold storage installation
In the process of cold storage installation, the use of cold storage power distribution boxes is a very important content, but most people are not very familiar with the normal operation of cold storage power distribution boxes. Today we will follow the refrigeration experts to learn about cold storage power distribution The correct operation method of the box
.
After the cold storage is installed, the wiring outside the cold storage distribution box must be protected by the correct method. For example, the wiring of steel pipe and hose, we had better place it in a place that is not easily damaged, otherwise it may cause The wiring of the cold storage power distribution box was unnecessarily damaged.
After the cold storage is installed, the power cord between the power distribution box and the machine tools is best placed in the middle of the bridge, and the bridge also needs to use the base to support it. Kuhua Refrigeration said that it is recommended that the bridge is not used Direct ground contact.
The piping outside the cold storage distribution box also needs to be unified, which is also an important content after the cold storage installation. If there is a phenomenon of inconsistency, then in the later use, there will be frequent failures and waste our unnecessary maintenance costs. I hope everyone should grasp this.
When installing the cold storage, you need to pay attention to the connection of the distribution box packaging machine or other heating equipment. When wiring, you need to stay away from the place close to the heating. The wiring is best placed in the connection box. The heater connection line is * good It is made of glass or ceramic pipe electric wires. For safety reasons, flammable electric wires are not allowed.
Outside the cold storage distribution box, all wires need to be placed in the connection box when they are connected. This is also an important part of the cold storage installation process. In addition, there must be no joints in the middle of the connection line.
The protection level of all connection boxes and wire entrances of the cold storage distribution box must be above IP55. This is a content that everyone needs to pay attention to when installing the cold storage.
It is better to use two wires to link the relay terminal block. If you need to link more than three wires, it is best to install other terminal blocks, otherwise it will also affect the normal use of the distribution box.
If the sensor is placed in a place that is easy to damage when wiring, it is best to use a hose to protect it. The use of the hose is best to be placed directly at the root of the sensor. This content is also during cold storage installation. Need attention.
At the same time, after the cold storage is installed, the normal use of the distribution box needs to be checked frequently. Once hidden dangers arise, they must be dealt with immediately, otherwise it will affect the normal use and may even cause economic losses. Hope Everyone must pay attention to inspection.
The above is the knowledge of the correct operation of the distribution box during the cold storage installation. In order to make the function of the distribution box function normally, we need to pay attention to these contents. This will play an auxiliary role for the normal use of cold storage.
Correct operation method and precautions of distribution box during cold storage installation
Recent related posts
-
08/13/2020
Correct operation method and precautions of distribution box during cold storage installation
In the process of cold storage installation, the use of cold storage power distribution boxes is a very important content, but most people are not very familiar with the normal operation of cold storage power distribution boxes.
-
08/13/2020
Compressor in the industrial chiller system produces wet stroke fault and troubleshooting
In the industrial chiller system, when the compressor sucks in wet steam, frost occurs on the cylinder wall, and the suction temperature and discharge temperature drop significantly. This is the wet stroke of the compressor, commonly known as frost.
-
08/13/2020
Cold storage refrigeration equipment cleaning sequence
In every well-designed and well-installed refrigeration installation, it is rare that the built-in electromechanical insulation layer is damaged and the electromechanical destruction is caused.
-
08/13/2020
Air-cooled modular cold and hot water unit configuration and takeover notes
The air-cooled modular hot and cold water unit is a combination of independent air-cooled heat pump units. At present, the modular unit is a very good model in the commercial air conditioning market.
-
08/13/2020
Adding method of refrigerant in central air conditioner
How to add refrigerant to central air-conditioning, what operating methods do you know? Let’s take a look with the editor of okmarts.com today!
-
08/13/2020
Acceptance standards after the cold storage design and installation are completed
A newly built cold storage, when it's time for acceptance, it will definitely be anxious. How can it be accepted to ensure quality and quantity? The editor of okmarts.com will briefly introduce it below.
-
08/13/2020
8 simple maintenance common sense of combined cold storage you must understand
We will inevitably have some small failures in the process of using the cold storage. If we can do a little simple troubleshooting, we can eliminate the failures in the shortest time and reduce losses.
-
08/12/2020
Have you figured out the "enthalpy" and "entropy" of the refrigeration system?
1. Enthalpy<br></br> It is a kind of energy, used to indicate the thermal state parameter of the state of the refrigerant, it represents the size of the total energy of the refrigerant; namely:
-
08/12/2020
How to judge the car air conditioner expansion valve ice block What are the symptoms
If there is moisture in the system, icing and blockage will occur at the expansion valve when the air conditioner is in refrigeration. After the blockage, the air conditioner will not be cooled.
-
08/12/2020
The phenomenon that the pressure switch of automobile air conditioner is broken
Poor contact of the contacts or malfunction of the pressure switch causes the compressor to fail or fail to function as a normal pressure protection.