Daily maintenance and performance characteristics of air-cooled chillers
Although the air-cooled chiller is equipped with multiple protection devices, these are all to prevent failures from directly damaging the unit. If the company wants to ensure that the air-cooled chiller has high cooling efficiency and long service life, it must remember to do regular maintenance.
1. Check the stability of voltage and current
When the air-cooled chiller works normally, the voltage is 380V (the voltage of DYJ-01A~DYJ-02A is 220V, and the voltage of other regions abroad also has 410V, etc.), and the current is normal within the range of 11A-15A;
2, check whether the refrigerant has decreased
This can be judged by the high and low pressure gauge values on the front of the air-cooled chiller. When the chiller is operating normally, the high pressure is 11-17kg, and the low pressure is 3-5kg. In shutdown state, both high pressure and low pressure are around 0.6kg;
3, regular cleaning system
When the air-cooled chiller is running for 6 months, the entire system, such as pipes, filters, condensers, fans, etc., must be cleaned, especially the fans. Like our commonly used fans, dust will affect heat dissipation, so the cooling efficiency will Directly lower.
Air-cooled chillers are called air-cooled chillers for short. It is also called air-cooled box chillers, air-cooled screw chillers, air-cooled low-temperature chillers, air-cooled piston chillers, and so on. It is one of our most commonly used chillers.
Since is the most commonly used, what are its unique characteristics? What problems should we pay attention to when installing and using it?
Air-cooled chiller performance characteristics:
1. The air-cooled chiller does not need to be equipped with additional water pumps, cooling towers, and cooling towers to make up water. The water system is clean and easy to use. It has advantages in water-scarce areas, super high-rise buildings, and occasions with high environmental requirements.
2. Air-cooled chillers use air as the cooling medium, and the air density is small, and the specific heat capacity is small. Under the same heat, the required air volume is large, so the heat exchange area is large, and the production cost and price are high.
3. At full load, the power consumption of air-cooled chillers is greater than that of water-cooled chillers. However, when the outdoor dry bulb temperature drops, the power consumption of air-cooled chillers can be greatly reduced.
Generally speaking, according to usage habits, the annual power consumption of air-cooled chillers is not much higher than that of water-cooled chillers. In addition, the cost of equipment maintenance for water-cooled chillers is higher than that of air-cooled chillers. The operation and maintenance cost of the machine may be slightly lower than that of a water-cooled chiller.

Related Info
Common auxiliary accessories and refrigeration methods for industrial chillers Common problems that should be paid attention to in the selection of cold storage forklifts Common sense of home appliances how to use an air conditioner for ten years Common sense of home appliances the correct posture for adding fluoride to air conditioners Daily maintenance and maintenance methods of ground source heat pumpsDaily maintenance and performance characteristics of air-cooled chillers
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
GATES Belt 5PK1395
US$34.23
Ealy Vane Pump 50T-36FRL-50T-14
Contact Us
Delkor Battery LN6605901095
US$175.65
IDEC Relay RU4V-NF-D48
US$8.19
Copeland Compressor RS64C1-CAA-252
Contact Us
IVZ Bearing 6228-ZZ
US$176.92
COKERY Belt 2 5M850JB
US$40.89
SUNON Fan GM1203PFV1-8.GN
US$12.00
Ding Zing Oil Seal UN35*45*10
US$1.92