Do you know that water chillers are prone to these problems
1. Reasons why the chiller can't refrigerate
1. The filter is blocked. When the filter is blocked, the dust on the condenser will accumulate, which will affect the cooling effect of the refrigeration equipment over time. If things go on like this, it may even cause refrigeration equipment to fail.
Solution: Clean the filter regularly or irregularly.
2. The content of coolant is low. If the content of coolant is too small, the equipment will not be able to absorb oil and the cooling effect will be reduced.
Solution: Check the coolant frequently to see if the coolant level is maintained between high and low, and add coolant in time when the coolant is too low.
3. Lack of Freon. In some early refrigeration equipment using Freon as a refrigerant, Freon will volatilize after a long time of use, thereby affecting the cooling effect.
Solution: Ober air conditioner reminds you that freon may be harmful to human body, so in this case, you should find a professional maintenance company to add it.
4. The power supply voltage is low or the power of the refrigeration equipment is not enough.
2. How to judge the lack of fluoride in the chiller?
The main manifestations are low fluorine pressure, decrease in cooling capacity, increase in return air temperature, increase in exhaust temperature, or naturally look at the evaporating pressure, if it can’t be cooled down, and the evaporating pressure is very low, it is naturally wrong if it is lower than 2-3Pa , It is necessary to doubt whether it is missing, but it may also be caused by other reasons. It is also wrong that the evaporation pressure drops rapidly from the temperature corresponding pressure to 2-3Pa after stopping for a long time and starting the machine.
3. What type of refrigerant is generally added to industrial chillers?
(Chlorodifuoromethane), molecular formula CHClF2, molecular weight 86.47. R-22 is a colorless, almost odorless gas at room temperature, non-combustible, non-corrosive, and minimally toxic. It can be liquefied into a colorless and transparent liquid under pressure. It is an HCFC refrigerant. Main use: Freon-22, molecular formula: CHClF2, molecular weight: 86.47. R-22 is widely used in household air conditioners, central air conditioners and other commercial refrigeration equipment; it can also be used as a raw material for polytetrafluoroethylene resin and an intermediate for fire extinguishing agent 1121.
4. What should I do if frost occurs during the operation of the chiller? How to solve?
1. Check whether the amount of refrigerant is within the standard range. Regardless of whether it is charged too much or too little, it will affect the normal operation of the chiller.
2. Are multiple chillers used in parallel? If the number of units to be turned on is large, check whether it is caused by the excessively long start-up time of the frosting unit (the combined unit has a control panel that can set the start and stop time of each chiller as required).
3. If it is a chiller, please check whether the opening of the expansion valve is too large. The small point can be fine-tuned (if it is an electronic expansion valve adjustable circuit control panel).
4. If the opening of the expansion valve is too small or clogged, the refrigerant supply will be reduced, which will lower the evaporation temperature and cause frosting on the evaporator fins; if the refrigerant does not evaporate and flow back Continued evaporation in the air pipe and compressor will cause frosting of the compressor and return pipe.
5. Check whether the filter is too dirty or the evaporator fins are too dirty, which makes the heat exchange effect poor, and the refrigerant evaporates and flows back to the return pipe and the compressor to continue to evaporate and cause frosting.
6. If the operating environment of the chiller is not good, or the air is not circulating, it will also cause poor heat dissipation and affect the frosting of the unit.
If the chiller has a frost failure, the company must promptly use professional methods to complete the troubleshooting to ensure the safe and stable operation of the chiller, and regularly check whether the various parts of the chiller are worn or damaged, and should be replaced in time. In addition, when an enterprise purchases a chiller, it should match the chiller reasonably according to production needs, so as to better use the chiller and reduce the cost of use of the enterprise.

Related Info
Five major lubrication methods for compressors in industrial chillers Factors influencing the evaporation capacity of air-cooled chiller evaporator Factors affecting the performance of cooling towers in water-cooled chillers Experts analyze the multi-line central air conditioner for you Electronic expansion valve replaces expansion valve on a large scale to solve two key problemsDo you know that water chillers are prone to these problems
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
NSK Bearing HR 30223 J
US$36.92
HIGH-TECH Vane Pump PV2R23-33-153-F-1R-UU-10
US$1096.15
TIMKEN Bearing TRB357024
US$130.77
Copeland Compressor MRA2-050A-CFB-8R0
Contact Us
ABB Servo Motor 3HAC033224-001
Contact Us
Bristol Compressor H26A38QDBEE
Contact Us
Mitsubishi Servo Motor HG-KR13
US$530.77