Factors that must be considered in the design of multi-line central air conditioning
The purpose of the multi-line central air-conditioning design is to deal with excess heat and to provide a comfortable living environment. The heat that causes discomfort to the human body mainly includes: heat introduced through the enclosure structure, solar radiation heat entering through external windows, human body heat dissipation, lighting heat dissipation, heat dissipation from other internal heat sources such as equipment, food or material Heat dissipation, heat brought in by penetrating air, and latent heat generated by various moisture dissipation processes. The purpose of central air-conditioning is to remove the heat that causes indoor heating and discomfort for the human body. This heat is related to the structure of the house and the performance of the equipment, but what factors should we consider when replacing it in the design?
1. The geographical location of the project
The temperature in spring is changeable, the temperature in autumn drops sharply, the winter is cold and the summer is very hot, the severe cold period is short, and the summer heat period is long
2. Room orientation
The load of the westward room should be increased appropriately (cooling load: West>East>South>North)
Three, the height of the house
If the storey height is more than 5 meters and empty, the load needs to consider the additional height (1 meter increase 20w/m2)
Fourth, the heat gain of the building
The inner area generally has 10-20w/m less load than the outer area room, the basement generally has 15-20w/m less load than the outer area room, and the top floor generally increases 20-30w/m2
5. Whether to consider heat exchange in winter
When there is a demand for heating in winter, a unit with EVI function is recommended
6. Multi-line central air-conditioning system pipe length
The pipeline is too long, consider the pipe length correction, increase the unit load
Seven, super ratio
When over configuration, the load is not less than the normal value
8. Remote indoor unit distance
The most remote indoor unit close to the pipe length application requirement, increasing the unit load.

Related Info
Common problems during debugging of refrigeration and air conditioning systems Component maintenance method of water-cooled chiller Cooling method of water-cooled chiller Daily maintenance of chillers and emergency treatment Eight aspects allow the chiller to achieve energy saving in managementFactors that must be considered in the design of multi-line central air conditioning
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Copeland Compressor ZPS40K5E-TFJ-600
Contact Us
Schneider Circuit Breaker QO340
Contact Us
ASHUN Overflow Valve SRV-06G-H
US$507.69
Dwyer Flowmeter VFC-132
US$246.15
AirTAC Air Cylinder SC250X15
US$461.73
Festo Air Cylinder DSBC-32-50-C-PPVA-N3
US$948.08
Autonics Temperature Controller TZ4H-A4C
US$203.08
Bristol Compressor H79A563DBVD
Contact Us
Kuebler Encoder 05.2400.2232.0200
Contact Us
Ebmpapst Fan 4606ZW 9244014806
Contact Us