1.Why control the impurity content and moisture content of the compressor and air conditioning system?
Impurities enter the friction surface of the moving parts of the compressor pump body, which can cause abnormal scratches and wear. Impurities entering the solenoid valve, expansion valve, control valve, capillary tube and shut-off valve in the freezer system can block the valve hole or make the valve closed tightly And failed.
Compressor moisture will mainly have several adverse effects:
The capillary tube and expansion valve will cause ice blockage, and the evaporator cooling tube will also freeze;
The metal material is corroded to form deposits;
The valve core is corroded and the closure is not tight;
The surface of the compressor pump body has a "copper plating" phenomenon;
Accelerates the deterioration of insulating materials, refrigerants, refrigerating machine oils and other materials.
2. What effect will the low voltage have on the air conditioning system?
If the voltage is too low, it is much lower than the specified operating voltage range of the compressor. Because the locked-rotor current value may not reach the operating current specification of the protector, it will cause the protector to fail to operate in time, causing the compressor motor to overheat or even burn. .
3. What is the function and principle of the compressor protector?
The function of the compressor protector is mainly to protect the compressor from accidents such as motor burnout when the compressor is in an abnormal condition.
Main principle: It depends on the internal heating wire of the protector and the internal resistance of the bimetallic sheet to make the bimetallic sheet act through the combined action of current heating and external conduction heat, thereby cutting off the circuit and protecting the compressor from damage.
4. How to make basic judgment and treatment after the compressor fails?
No suction and discharge pressure: first check the compressor wiring, pipeline connection, main and auxiliary coil impedance, compressor insulation withstand voltage and other basic items. If they are normal, it is recommended to remove the compressor for idling to check whether there is suction and exhaust.
Suction and exhaust method is: when the compressor is running, press your finger against the exhaust port for a few seconds, then let go, observe whether there is gas ejection, and a small amount of oil is normal. If there is suction and discharge, the discharge pressure is large, indicating that the compressor can work normally, otherwise the compressor is abnormal.
5. Why should liquid refrigerant be prohibited from flowing back into the suction chamber of the compressor?
If the liquid refrigerant directly enters the suction chamber of the compressor, the volume of the compressor becomes smaller and smaller and the pressure rises sharply during the rotation of the crankshaft, resulting in abnormal force or even damage to the pump body parts and valve plates. Liquid shock can also cause abnormal vibration and noise of the compressor.
6. Why shouldn't the refrigerant recovery time of the air conditioner be too long?
Air conditioning should not be too long for refrigerant recovery operation. Because the refrigerant recovery time is too long, the temperature of the exhaust gas will be very high due to the extremely thin refrigerant gas sucked in, causing the temperature of the pump body parts of the compressor to rise rapidly. Excessively high temperature makes the expansion difference of each part too large, which causes the fitting gap of some parts to become smaller or even disappear, and eventually results in abnormal scratches or wear.
7. What is the effect of connecting the wrong line of the compressor? Why can't the protector protect?
Compressor wrong wiring will make it unable to work normally. According to different wiring error methods, there will be stalling, reverse rotation, stop after starting, etc., and it may cause the compressor motor to burn directly.
Because the compressor protector is selected based on the compressor's correct wiring and the operating characteristics of the protector under abnormal operating conditions, it is impossible to ensure that the compressor is protected when the wrong wire is connected. In the case of miswiring, it is difficult to protect the motor through the protector.
8. For the same system, do you need to adjust the system for compressors of different manufacturers?
Due to the different performance characteristics of compressors produced by different companies, for a specific compressor, only under specific refrigerant flow rate, suction and discharge pressure, temperature and other conditions will show the best performance.
Therefore, in the same refrigerator system, it is best to adjust the system separately when using different compressors to ensure that the compressors used work properly at the appropriate refrigerant flow rate, suction and exhaust pressure, and temperature conditions, so that they can be effective Extend the service life of the compressor and achieve the best use effect.
9. Why is the temperature of the compressor motor coil required during operation?
Insulation class of insulating materials used in compressor motors (Insulation class: A (105 ° C), E (120 ° C), B (130 ° C), F (155 ° C), H (175 ° C)) And heat resistance characteristics. For motor enameled wire, excessive temperature will lead to a reduction in the amount of film cocoons, a decrease in friction resistance K, easy peeling, an insulation breakdown voltage and a decrease in insulation resistance, etc., which greatly reduces the service life.
In addition, excessive temperature of the motor can cause excessive elution of high molecular substances in the insulating material. These substances will precipitate and accumulate somewhere in the system or the compressor exhaust port, thereby affecting the performance of the compressor and the system. In addition, the coil temperature is too high will cause the compressor motor efficiency to decrease.
10. Why the compressor can be restarted at least 3 minutes after shutdown?
When the compressor starts, there will be more refrigerating machine oil entering the air conditioner system with the refrigerant circulation. If there is not enough running time, [this source: Refrigeration Encyclopedia], then the refrigerating machine oil will not return to the compressor cavity in time. Frequently starting and shutting down shortly will result in a low oil level in the compressor, which may cause poor lubrication of the mechanical moving parts of the compressor. In addition, the shutdown time of more than 3 minutes is mainly to give the system enough pressure balance time, otherwise the compressor will not start normally due to the presence of high and low pressure.
11. Why can't the compressor run under "vacuum conditions"?
The so-called "vacuum condition" is not an absolute vacuum state, but a very low pressure state, and gas molecules will ionize at very low pressure.
According to the actual experimental results, the compressor terminal has the lowest breakdown voltage around the internal pressure of the compressor of 3.5mmHg. When it is energized, it will easily cause breakdown and internal carbon deposition, damage the insulation of the sealed terminal, and make the compressor in operation when it is severe An accident occurred in which the sealing post burned out. Therefore, power should be avoided when the compressor is evacuated.
Recent related posts
-
06/14/2020
Frequently asked questions about refrigeration compressors, do you know these
Frequently asked questions about refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?
-
06/14/2020
Don't be afraid if the refrigeration system is clogged. Here are retrieval and cleaning methods
Don't be afraid if the refrigeration system is clogged. Here are retrieval and cleaning methods Typical features of clogging 1. The refrigerator or air conditioner does not cool for a long time. 2. The suction pressure drops, and even a vacuum stat ﰸ2 䀀 ᅵ皥 䖒皦
-
06/14/2020
Analysis of common failure causes of totally enclosed refrigeration compressor
Analysis of common failure causes of totally enclosed refrigeration compressor Running end (R), starting end (S), common end (C), the resistance between RS is greater than that between SC and RC. The resistance between RS is equal to the resistance betwe ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི
-
06/14/2020
What is the energy efficiency ratio of air conditioning
What is the energy efficiency ratio of air conditioning What does the air-conditioning energy efficiency ratio mean? How to calculate the air-conditioning energy efficiency ratio?
-
06/14/2020
There is solar energy in the water vapor, which can be used for heating and cooling
There is solar energy in the water vapor, which can be used for heating and cooling What is water vapor energy? This unfamiliar term is actually not difficult to understand
-
06/14/2020
The cold storage was built in this way, which actually saved nearly half of the electricity bill!
Compared with the ordinary refrigerator, the cold storage has a larger cooling area, and because of the large cooling area of the cold storage, the power consumption is relatively large.
-
06/14/2020
The application of photovoltaic central air-conditioning technology will continue to extend
The application of photovoltaic central air-conditioning technology will continue to extend The "Renewable Energy Power Quota Assessment Measures (Trial)" has been discussed and approved in principle by the National Development and Reform Commission's di ﰸ2 䀀
-
06/14/2020
Technical characteristics of solar air conditioning
Technical characteristics of solar air conditioning Technical characteristics: The current implementation of solar air conditioners mainly relies on the sun's thermal energy for cooling and heating
-
06/14/2020
Solar driven adsorption refrigeration
Solar driven adsorption refrigeration Shanghai Jiaotong University Wang Ruzhu and other nearly 20 years of painstaking research "adsorption refrigeration adsorption mechanism, cycle construction and thermal design theory" won the second prize of the 2014 ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ
-
06/14/2020
Scientists use magnetic fields and deformed alloys to develop refrigeration systems
Scientists use magnetic fields and deformed alloys to develop refrigeration systems Apart from redundant functions such as touch screens and built-in cameras, basic refrigerator technology has not changed much in decades.