How to control the air distribution of a small cold storage
How to better control the air distribution of a small cold storage, some friends may not understand, today okmarts.com editor will tell you!
To make the circulation in all warehouses as uniform as possible is a difficult and hot issue in the research of ice temperature cold storage technology. As a traditional cold storage, the air cooler is hoisted on the top of the storage body, the cold air is blown forward, and the air is returned from the back of the air cooler.
The protection structure of the ice-temperature storage here is a double-layer structure with an outer insulation structure and an inner non-insulation structure. There is an air interlayer between the inner and outer storage bodies. The air supply method is ordered and the air is returned near the bottom of the storage. , The airflow rises back to the evaporator along the air interlayer. There is a static pressure box layer under the air supply port. The airflow forms a greater pressure in the static pressure box layer, so that the air is sent down evenly into the small cold storage to form a piston flow . The speed field in the warehouse is very uniform, no dead ends occur, and the wind speed in the warehouse is very small, usually less than 0.1m/s. A small wind speed can greatly reduce the dry consumption of the fruit. After the inspection of the practice flow field in the warehouse, such air supply The arrangement method is more reasonable and can ensure the uniformity of the flow field in the reservoir.
In order to reduce the temperature fluctuation of the ice temperature storage, the most important thing for the storage protection structure is the heat storage function of the protection structure and the anti-interference function of the protection structure. This can be done by adding the thickness of the protection structure or adding an air layer. To complete, our plan for the ice-temperature warehouse is completed by adding an air interlayer. It is controlled by precision instruments, including temperature control and sensor arrangement. The temperature control accuracy selected in the small cold storage is ±0.1℃. A total of 10 sets of temperature sensors are arranged in different directions, and the data obtained are all entered into the assembly control cabinet for distinction, and then the cooler and humidifier are controlled.
How to control the air distribution of a small cold storage
Recent related posts
-
08/20/2020
How to control the air distribution of a small cold storage
How to better control the air distribution of a small cold storage, some friends may not understand, today okmarts.com editor will tell you!
-
08/20/2020
How to calculate air conditioner power-what is air conditioner power
The cooling power of the air conditioner refers to the total power consumed within the rated time when the air conditioner is in cooling operation, and the unit is W. It should be noted that the cooling power and cooling capacity are different.
-
08/20/2020
How to adjust the energy of the compressor of the screw chiller
The compressors used in screw chillers generally have brands such as Taiwan Hanbell and German Bitzer, which belong to the screw compressor series. An obvious feature of this type of compressor is that it can perform an energy adjustment action on it according to different
-
08/20/2020
How much power does the air conditioner save most
With the advent of the dog days, T-shirts and long skirts have been unable to meet people's needs for cooling off, so various cooling measures have been taken. Air conditioners are naturally the first choice to cool off the heat.
-
08/20/2020
How much is the temperature of the industrial chiller to prevent condensation
Condensation water in the industry is mainly caused by the large temperature difference between the ambient temperature and the cooling water temperature of the chiller.
-
08/20/2020
How can fruit and vegetable cold storage meet energy-saving requirements
There are many factors to consider for energy saving in cold storage, including the performance of cold storage refrigeration system, the selection of refrigerant, the selection of compressor condenser and evaporator,
-
08/20/2020
High and low temperature test chamber refrigeration failure What unique secrets do you need to master
The high and low temperature box does not refrigerate, which means that there is a problem with the compressor. A complete refrigeration system is composed of a compressor, a condenser, a throttling device and some auxiliary equipment.
-
08/20/2020
Frequency conversion energy-saving control method of central air-conditioning water circulation system
The energy consumption of the air-conditioning water system accounts for a large part of the entire air-conditioning system. Therefore, it is of great significance to study the energy saving of the air-conditioning water system.
-
08/20/2020
Failure analysis Is the air conditioner buzzing about to explode
Summer is the peak season for air-conditioning, and the frequency of air-conditioning in the home has increased significantly. After frequent use, some friends say that the air-conditioning in the home is always buzzing.
-
08/20/2020
Evaporator fouling is harmful. Several common evaporator fouling measures must be
Evaporator and preheater fouling means that the concentrated salt wastewater contains a large amount of impurity salts, which form crystal nuclei after continuous evaporation and concentration.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
Sanyo Compressor C-SB303H8F
Mean Well Power Supply MSP-600-5
Siemens Contactor 3RT1054-3NF36
Huba Control Transmitter 699.930007101