How to eliminate the difficult problems of the salt spray test chamber

How to eliminate the difficult problems of the salt spray test chamber Many people will blame the poor quality of the salt spray test box in actual use. However, the relevant departments have used statistical data to tell us that more than 50% of these problems are caused by operation. Only 5% is the quality problem of the salt spray test box itself. Therefore, it is very important whether the operation of the salt spray test chamber is standardized. However, once the salt spray test box fails, let's not be in a hurry. Today's editor summarizes the troubleshooting method of the salt spray test box for not heating up. You can learn it! 1. The cabinet of the salt spray test chamber does not heat up: 1. Check whether the water injection volume inside the tank is added to the water level; 2. Check whether the heating tube inside the cabinet is damaged, and whether the voltage at both ends of the heating tube is normal, whether there is 220V voltage input, check whether the real-time temperature display of the instrument is normal, if the display temperature is found to be too high, the device will automatically display overtemperature protection; 3. Whether the set temperature point of the meter is correct, whether the sensor transfer temperature is normal, whether the meter heating output is normal, check whether the solid state relay is damaged, and check whether the over-temperature protection point inside the meter is set too low; 2. The reason why the saturator of the salt spray test chamber does not heat up is as follows: 1. Check whether the water level inside the saturator meets the requirements; 2. Check whether the over-temperature alarm lamp on the panel is on, check whether the voltage at both ends of the heating tube of the saturator is normal, whether there is a 220V voltage input, check whether the temperature display on the meter is normal, and whether the output is normal, if the voltage is normal, the saturator If the temperature is not increased, it can be determined that the heating tube is damaged; 3. If there is no voltage, the saturator will not heat up, check whether there is DC voltage at the signal end of the solid state relay, and whether there is AC voltage at the output end. If there is no signal from the solid state relay, it will not output the voltage normally. If this happens, check the output terminal of the meter for DC voltage output. If there is no DC voltage, it can be determined that the meter is damaged.

Recent related posts

Customers frequently viewed

New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

IWAYA DENKI Water Pump 25CJT0752

US$2307.69
New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

ROTEN Mechanical Seal 8E5K-22-X

US$384.62
New In stock for sale, Bitzer Compressor 4PES-12Y

Bitzer Compressor 4PES-12Y

US$4750.00
New In stock for sale, Danfoss Solenoid Coil BN024BS

Danfoss Solenoid Coil BN024BS

US$191.02
New In stock for sale, Danfoss Transmitter 060N1338

Danfoss Transmitter 060N1338

Contact Us
New In stock for sale, NKK Switch UB-25

NKK Switch UB-25

US$23.08
New In stock for sale, Servo Fan MADC24B4Q

Servo Fan MADC24B4Q

US$172.31
New In stock for sale, Kuebler Encoder 8.5000.B548.4096

Kuebler Encoder 8.5000.B548.4096

Contact Us
New In stock for sale, Schneider Contactor LC1K0910M72

Schneider Contactor LC1K0910M72

Contact Us
New In stock for sale, Sanyo Denki Fan 9L0412J3D01

Sanyo Denki Fan 9L0412J3D01

US$22.59