How to maintain the refrigeration system on a daily basis Many users have no professional personnel or simple maintenance of the refrigeration system when using the refrigeration system, which causes the system to be directly paralyzed once the problem occurs, and can not be used directly. It also takes a lot of manpower and material resources to solve, and it is very time-consuming. Here we introduce the daily simple maintenance of the refrigeration system. First of all, we installed a new set of Copeland compressors. The cleanliness of the new system should be relatively poor. When the new system is installed, there will be many welding places. Naturally, many impurities will run into the system, so the new The Copeland compressor system needs to be replaced once after about 30 days of operation. The refrigeration oil and the drying filter in the Copeland compressor system need to be replaced once. See if you want to replace the second refrigeration oil and filter. ; Also in Beijing in such weather in spring and summer, there will be that kind of catkin hairs flying around, these hairs * easy to fly to the outdoor unit shell, so that the outdoor unit fan is not good for a long time Will affect the system. We are not good at cleaning the catkins on the outdoor unit. Therefore, it is better to make a thin iron mesh cover on the outside so that it is easier to clean. When using the refrigeration system, there are no people or simple daily maintenance of the refrigeration system, resulting in the system directly paralyzed once the problem occurs, it can not be used directly, and it takes a lot of manpower and material resources to solve, and it is very time-consuming. Here we introduce the daily simple maintenance of the refrigeration system. First of all, we installed a new set of Copeland compressors. The cleanliness of the new system should be relatively poor. When the new system is installed, there will be many welding places. Naturally, many impurities will run into the system, so the new The Copeland compressor system needs to be replaced once after about 30 days of operation. The refrigeration oil and the drying filter in the Copeland compressor system need to be replaced once. See if you want to replace the second refrigeration oil and filter. Also in Beijing in this weather, spring and summer will have catkin hairs flying everywhere. The easiest of these hairs is to fly to the outdoor unit shell, so it is not good for the outdoor unit to fan the wind for a long time. Impact on the system. We are not good at cleaning the catkins on the outdoor unit. Therefore, it is better to make a thin iron mesh cover on the outside so that it is easier to clean.

Related Info
Identify the authenticity of the compressor Precautions for cold storage acceptance Five items to pay attention to when using Copeland compressors Solutions to Copeland Compressor Insufficient Lubrication Failure Performance Difference between original and refurbished Emerson Copeland Scroll compressorHow to maintain the refrigeration system on a daily basis
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Sanyo Denki Servo Motor Q2AA13100BXS0J
Contact Us
CCS Switch 646PEM31
US$1311.00
Copeland Compressor D4SA-100X-AWX
Contact Us
Copeland Compressor ZBD38KCE-TFQ-260
Contact Us
Donaldson Filter P782106
US$339.69
BKD Bearing NAST20ZZ
US$21.00
Schneider Contactor LC1D066BD
Contact Us