How to solve the problems encountered during the operation of 120KW cold air-cooled compressor

The 120KW cold capacity air-cooled compressor mainly has three related systems: refrigerant circulation system, water circulation system and automatic electrical control system. Sixth, when the chiller is not used for a long time, the water in the water tank should be discharged through the drain valve and the drain nut under the water pump should be screwed. The remaining water in the pump to prevent the water system from freezing due to the low ambient temperature and the expansion of the evaporator causing refrigerant leakage or damage to the impeller of the pump. The product uses a 7-inch color touch screen to display the input temperature curve to record the entire system as a fully enclosed system at low temperature. No water absorption to ensure the purity of the cold and heat conductive medium. Prevent ice crystals from increasing the life of the thermal fluid. In winter, it can recover heat without large ventilation pipes and circulating water pipes in the refrigeration machine room. It does not have low insulation costs. It is convenient to measure and install, low maintenance costs, and flexible adjustment.
The second time I heard the sound of the compressor running, I could only hear the clear movement sound of the valve plate. Quickly cause the compressor exhaust temperature to be too high. In actual operation, the high compressor exhaust temperature must not exceed the suction pressure of the industrial chiller. The suction temperature, exhaust pressure, and exhaust temperature are related to each other, but not one-to-one correspondence. In the application, since the exhaust pressure is close to the condensing pressure, the suction pressure is close to the evaporating pressure, so the suction pressure of the compressor is the evaporating pressure. The exhaust pressure of the compressor is the condensing pressure, and the pipeline resistance loss is not considered. The market provides more distinctive products.

How to solve the problems encountered during the operation of the 120KW cold air-cooled compressor.According to actual needs, customers can choose different air-cooled fan prices. Which one is a good chiller in Wuhan? Which is a good ice chiller in Wuhan? Which one to choose in Wuhan, Hubei Refrigeration equipment This is a large-scale enterprise engaged in the production and manufacture of chillers. It is impossible to make full use of fresh air in excessive seasons.

Drain the refrigerant and drain the oil at the same time and hit the shut-off valve of the high-pressure meter 120KW cold air-cooled compressor. Problems encountered during operation How to solve the high-pressure protection water cut-off protection There is over-current protection Leakage protection continuous and open-phase protection high temperature protection Sensor failure, low liquid level alarm and other multiple safety protections. They can provide cooling and heating and domestic hot water production. When the sound of full penetration is the impact sound, the liquid impact, the sound of the refrigerant flowing in the expansion valve, the sound of the cooling fan, the sound of the cooling fan. Listen to the sound of the solenoid valve working.

If the indoor unit is hot, the electrical control may run and cut off the power and stop the operation. 120KW cold air-cooled compressor water temperature machine is a type of mold temperature machine. Because water is used as a heat medium, it is also called water-carrying mold. Temperature machine.

How to solve the problems encountered during the operation of the 120KW cold air-cooled compressor. Sincerely thank the old customers for their trust and support. Most of the high-noise units are hidden in the ceiling air-cooled water chiller to bring certain difficulties to maintenance.