Protection device for air-cooled chiller refrigeration compressor
What are the protective devices of the air-cooled chiller refrigeration compressor? Are all explanatory? Let's learn about it with okmarts.com editor today!
1. Internal thermostat (installed inside the compressor)
In order to prevent the air-cooled chiller from running uninterruptedly for 24 hours, resulting in high-load operation of the compressor, defective electromagnetic switch, overcurrent caused by shaft holding, or motor burnout caused by motor temperature, compressors are installed inside the compressor The internal thermostat, which is installed on the neutral contact of the three-phase motor, protects the motor by simultaneously cutting off the three phases when an abnormality occurs.
Two, electromagnetic switch
The electromagnetic switch is used to control the operation of the refrigeration compressor of the air-cooled chiller of the air-cooled chiller, and the switch is to be stopped for the purpose of stopping, and the installation must be kept vertical. If the installation is wrong, the spring pressure of the node may change and noise , Resulting in lack of phase operation, for the compressor model with a direct power-off protector inside, no protector is required.
Three, reverse phase protector
Scroll compressors and piston compressors have different structures and cannot be reversed. Because the three-phase power supply of the air-cooled chiller will cause the compressor to reverse phase, it is necessary to install a reverse phase protector to prevent the refrigeration compressor from reversing. . After installing the reverse phase protector, the compressor can run in the normal phase, but not in the reverse phase. When the reverse phase occurs, the two wires of the power supply can be changed to the normal phase by swapping.
Four, exhaust temperature protector
In order to protect the compressor under high load operation or insufficient refrigerant, the air-cooled chiller system needs to be equipped with an exhaust temperature protector, and the exhaust temperature is set to be within the range of 130±5°C to compress When the machine stops, this temperature value refers to the detected temperature within 10cm of the compressor exhaust pipe from the outlet.
Five, low voltage switch
In order to protect the air-cooled chiller compressor from running when the refrigerant is insufficient, a low pressure switch is required. When the setting is above 0.03mpa, the compressor stops running. Once the compressor is running under the state of insufficient refrigerant, the temperature of the compressor part and the motor part will rise instantaneously. At this time, the low pressure switch can be used to protect the compressor from damage and the motor that cannot be protected by the internal temperature controller and the exhaust temperature protector. Burn it for protection.
Six, high voltage switch
The compressor can be stopped when the high pressure pressure rises abnormally, and the operating pressure is set below 3.0mpa.

Related Info
Precautions for the selection of fan coils for large central air conditioners Precautions for using purifier Precautions for water treatment of central air conditioning chillers Precautions on how to prevent freezing in winter chillers Principles and advantages of water-cooled air conditionersProtection device for air-cooled chiller refrigeration compressor
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
FYH Bearing UCFS310
US$69.23
Pro-face HMI PFXGP4201TADF3C
Contact Us
Danfoss Expansion Valve 068Z3370
US$148.46
3 water pump EQS800
US$569.23
Copeland Compressor ZR144KCE-TF5-265
Contact Us
Daikin Solenoid Valve KSO-G03-3DN-30-EN
US$315.85
B&R Module X20AI2632
Contact Us
Copeland Compressor ZB76KQE-PED-550
Contact Us
Ebmpapst Fan 6224N/2P-208
Contact Us