Protection device for air-cooled chiller refrigeration compressor

Protection device for air-cooled chiller refrigeration compressor

What are the protective devices of the air-cooled chiller refrigeration compressor? Are all explanatory? Let's learn about it with okmarts.com editor today!

   1. Internal thermostat (installed inside the compressor)

In order to prevent the air-cooled chiller from running uninterruptedly for 24 hours, resulting in high-load operation of the compressor, defective electromagnetic switch, overcurrent caused by shaft holding, or motor burnout caused by motor temperature, compressors are installed inside the compressor The internal thermostat, which is installed on the neutral contact of the three-phase motor, protects the motor by simultaneously cutting off the three phases when an abnormality occurs.

   Two, electromagnetic switch

The electromagnetic switch is used to control the operation of the refrigeration compressor of the air-cooled chiller of the air-cooled chiller, and the switch is to be stopped for the purpose of stopping, and the installation must be kept vertical. If the installation is wrong, the spring pressure of the node may change and noise , Resulting in lack of phase operation, for the compressor model with a direct power-off protector inside, no protector is required.

   Three, reverse phase protector

Scroll compressors and piston compressors have different structures and cannot be reversed. Because the three-phase power supply of the air-cooled chiller will cause the compressor to reverse phase, it is necessary to install a reverse phase protector to prevent the refrigeration compressor from reversing. . After installing the reverse phase protector, the compressor can run in the normal phase, but not in the reverse phase. When the reverse phase occurs, the two wires of the power supply can be changed to the normal phase by swapping.

   Four, exhaust temperature protector

In order to protect the compressor under high load operation or insufficient refrigerant, the air-cooled chiller system needs to be equipped with an exhaust temperature protector, and the exhaust temperature is set to be within the range of 130±5°C to compress When the machine stops, this temperature value refers to the detected temperature within 10cm of the compressor exhaust pipe from the outlet.

   Five, low voltage switch

   In order to protect the air-cooled chiller compressor from running when the refrigerant is insufficient, a low pressure switch is required. When the setting is above 0.03mpa, the compressor stops running. Once the compressor is running under the state of insufficient refrigerant, the temperature of the compressor part and the motor part will rise instantaneously. At this time, the low pressure switch can be used to protect the compressor from damage and the motor that cannot be protected by the internal temperature controller and the exhaust temperature protector. Burn it for protection.

   Six, high voltage switch

  The compressor can be stopped when the high pressure pressure rises abnormally, and the operating pressure is set below 3.0mpa.

Recent related posts

Customers frequently viewed

New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

IWAYA DENKI Water Pump 25CJT0752

US$2307.69
New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

ROTEN Mechanical Seal 8E5K-22-X

US$384.62
New In stock for sale, FYH Bearing UCFS310

FYH Bearing UCFS310

US$69.23
New In stock for sale, Pro-face HMI PFXGP4201TADF3C

Pro-face HMI PFXGP4201TADF3C

Contact Us
New In stock for sale, Danfoss Expansion Valve 068Z3370

Danfoss Expansion Valve 068Z3370

US$148.46
New In stock for sale, 3 water pump EQS800

3 water pump EQS800

US$569.23
New In stock for sale, B&R Module X20AI2632

B&R Module X20AI2632

Contact Us
New In stock for sale, Ebmpapst Fan 6224N/2P-208

Ebmpapst Fan 6224N/2P-208

Contact Us