Precautions during use of industrial chiller compressor
One of the most important components in industrial chillers is the compressor. Compressor damage means that the chiller is scrapped. Therefore, the compressor is a very important consideration when choosing a chiller. So what are the compressor options for the chiller? For important details, let's learn about it with the editor of okmarts.com!
1. Observe whether the oil level of the industrial chiller oil sump and the lubricating oil in the oiler are below the scale line. If it is low, it should be filled up in time (the dipstick must be stopped for inspection);
2. Frequently check whether there are sundries or even conductive objects in the compressor motor, whether the coil is damaged, whether the stator and rotor are rubbed, otherwise the motor will burn out after the motor is started;
3. Gas storage tanks, coolers, and oil-water separators must always release oil and water;
4. Carefully check the sound of the cylinders and moving parts at all levels, and distinguish whether it is working normally according to the "listening". If abnormal sounds are found, the machine should be shut down immediately for inspection;
5. Pay attention to whether the motor temperature rise, bearing temperature, voltmeter, and ammeter indicate normal conditions. The current must not exceed the rated current of the motor. If it exceeds, find the cause or shut down for inspection;
6. Pay attention to whether the indicated values of the pressure gauges at all levels, the pressure gauges on the gas tank and the cooler, and the lubricating oil pressure gauge are within the specified range;
7. Check whether the cooling water temperature and flow rate of the industrial chiller are normal;
8. Check the lubricating oil supply and the lubricating system of the motion mechanism (some compressors are equipped with plexiglass baffles on the side of the crosshead guide rail of the fuselage, so you can directly see the movement of the crosshead and the supply of lubricating oil), Cylinders and packings can be inspected by one-way lubrication, and the oil injection into the cylinder can be checked;
9. Touch with your hand and check whether the temperature of the suction and exhaust flaps at the cross guide rail of the crankcase of the fuselage is normal;
10. The lubricating machine used should be precipitated and filtered. The compressor oil should be used differently in winter and summer;
11. If it is a compressor of a water-cooled industrial chiller, water cannot be supplied immediately after the water is cut off to avoid cylinder cracks due to uneven heating and cooling. After the shutdown in winter, the cooling water should be discharged to avoid freezing and cracking of the cylinder and other places;
12. Pay attention to the sanitation of the compressor and its equipment;
13. Check whether the compressor vibrates and whether the anchor bolts are loose or fall off;
14. Check whether the pressure regulator or load regulator, safety valve, etc. are sensitive.
Precautions during use of industrial chiller compressor
Recent related posts
-
08/20/2020
Precautions during use of industrial chiller compressor
One of the most important components in industrial chillers is the compressor. Compressor damage means that the chiller is scrapped. Therefore, the compressor is a very important consideration when choosing a chiller.
-
08/20/2020
Operation procedure of chilled water system
In order to better ensure the normal refrigeration of the chiller, the general chilled water system operation should be carried out when the outdoor temperature is higher than about 30℃,
-
08/20/2020
Operation guide after the refrigeration compressor burned out
The refrigeration compressor is burned, and the residual refrigerating oil has been carbonized, acid-containing, and dirty in the pipe; and after the compressor is removed, the original system pipe must be corroded with the air,
-
08/20/2020
Multi-line system characteristics and common faults
Multi-connection is commonly known as "one-to-many". A multi-connection system is an outdoor unit connected to multiple indoor units, and each indoor unit can be freely run/stopped, or grouped, or centralized.
-
08/20/2020
Matters needing attention during installation of clean air duct and equipment
Attention should be paid to the installation of air ducts and equipment of clean air conditioning systems:
-
08/20/2020
Master these little knowledge, don’t be afraid of not understanding household central air-conditioning
Household central air conditioners have been chosen by more and more people, but there are still very few people who understand household central air conditioners. Therefore, we often find
-
08/19/2020
Maintenance solutions for refrigeration system of constant temperature and humidity test chamber
In the maintenance practice of the constant temperature and humidity test chamber, once the capillary tube is blocked in the refrigeration system, the evaporator and the condenser tube and the connecting pipe are broken or welded
-
08/19/2020
Maintenance of closed cooling tower
Regarding the maintenance of the closed cooling tower, it can be divided into daily cleaning work and daily maintenance. Then, in these two aspects, let's talk about the maintenance of the closed cooling tower.
-
08/19/2020
Maintenance method of low temperature brine chiller
Low-temperature refrigerators should pay more attention to the maintenance of the water condenser. A small failure may be an invisible killer of the later equipment, so please pay more attention to the maintenance and cleaning of important parts of the refrigerator,
-
08/19/2020
Knowledge of two air conditioners the same and different between evaporator and condenser
Condenser and evaporator are heat exchangers, which are widely used in refrigeration systems of high and low temperature alternating damp heat test chambers, constant temperature and humidity test chambers and other equipment.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
BOURNS Encoder ECW1J-R24-CC0024
Sanyo Denki Fan 109BJ12MC2
YUKEN Overflow Valve EFBG-06-500-C-E-51
HENGSTLER Encoder RI76TD/2048AD.4A38RF