refrigerating system 4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of the steel tank by temperature-pressure is 1500; the total amount of side internal pressure [direction facing outward] is; 339000 In addition to the pressure that may exist in the refrigerant steel tank;; There may also be a large pressure in the nitrogen and oxygen steel tanks;; Transportation of nitrogen and oxygen steel tanks;; The allowable pressure is 2500;; Unless there is a safety insurance; otherwise Can not move; the same should also be fixed on the trolley with a chain;; The steel tank without the safety risk can break the steel tank valve when it arrives; The pressure in the tank will make the steel tank suddenly move forward like an air-filled balloon Before using nitrogen; the pressure of nitrogen must be adjusted; the pressure in the steel tank is too high;; it is difficult to connect with the system; if the operator puts nitrogen under the pressure of the steel tank; directly charge the system; then the refrigeration system will burst; If such weakness is on the compressor cylinder head; it is very dangerous; For the same reason; before using oxygen; the pressure of oxygen must also be adjusted; in addition, the connection pipe of oxygen must be absolutely oil-free;; if there is residual oil in the interface of the oxygen regulator, it will cause an explosion; such an explosion will be enough for the operator The pressure regulator is used to blow off; oxygen is usually used together with acetylene; acetylene bottle does not have the pressure of nitrogen and oxygen steel tanks but must also be given the same attention; because acetylene is very easy to explode; pressure relief valve must also be used; Special trolley; use the chain to fix the steel cylinder on the trolley and ensure that there is a safety insurance; all stored steel cylinders must have positioning support to avoid lying down; and according to different color standards, decompose and discharge 4.2 Electrical hazards The electrical hazards that often occur during burning caused by drinking out; drinking ribs on various lines is impossible if the power is cut off; therefore we must understand the live operation method of the circuit; If the wire is live; and you think that the components are in normal operating state; then don’t worry, only when the uncontrolled power supply appears [contacting two live wires at the same time] can you get injured. Electric shock When you become part of the circuit ;; electric shock will occur;; the heart will be hurt when the current passes through your body; ---- stop the heart from beating, ------ if it does not resume the heartbeat immediately, it will cause death; the best The way is of course to take first-aid measures; including life-saving CPR [cardiopulmonary recovery] method; safety precautions; to avoid electric shock;, to avoid becoming a conductor between two live conductors or between the live wire and the ground; electricity will definitely find circulation Path; and the higher the voltage you are exposed to; possible The greater the damage o; in the refrigeration and air-conditioning industry; we, the contact voltage is 460 volts; up to 560 volts o; therefore, we must understand the power supply voltage used in the work and related precautions; never be the body as a power source aisle
refrigerating system
Recent related posts
-
07/17/2020
refrigerating system
4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of
-
07/17/2020
Empty and replace the expansion valve after servicing the refrigeration system
Let's introduce the operation process when replacing the expansion valve in the refrigeration system. In the system, when the low pressure of the system is under pressure control, short-circuit the controller before venting the system to prevent the system from jumping during vacuum.
-
07/17/2020
Emerson Copeland Compressor
After the compressor of the refrigeration system is used for a period of time, the Emerson Copeland compressor system will reduce the refrigeration oil in the oil return system and natural loss of the Copeland compressor when it is running, so it is necessary to add refrigeration to the compressor after a period of time. oily.
-
07/17/2020
How to tell the authenticity of Emerson semi-closed Copeland compressor
How to tell the authenticity of Emerson semi-closed Copeland compressor In the market, there are customers who reflect that they are buying fake Emerson semi-closed Copeland compressors. Here, in order to allow customers to better identify the authenticity of Emerson semi-closed Copeland compressors, they freeze in Emerson Environmental Optimization Technology (Shenyang) Machinery Co., Ltd.
-
07/17/2020
Refrigerant used by Emerson Copeland compressor
With the global emphasis on environmental protection, our refrigeration industry is also the same, and gradually use some environmentally friendly refrigerants. Previously, the refrigerant used by Emerson Copeland compressors was R22, and R22 was not an environmentally friendly refrigerant. Later, Emerson Copeland Compressors gradually changed the compressors to use environmentally friendly refrigerants.
-
07/17/2020
How to clean the central air conditioning system
Many companies need the central air conditioner of the all-in-one machine to cool the equipment. If the equipment takes a long time or if one of the accessories in the system is broken, we need to replace it. If the equipment is used for a long time, many impurities will remain in the system.
-
07/17/2020
How to maintain the refrigeration system on a daily basis
Many users have no professional personnel or simple maintenance of the refrigeration system when using the refrigeration system, which causes the system to be directly paralyzed once the problem occurs, and can not be used directly. It also takes a lot of manpower and material resources to solve, and it is very time-consuming.
-
07/17/2020
Difference between original and refurbished Emerson Copeland Scroll compressor
Difference between original and refurbished Emerson Copeland Scroll compressor Now the most important thing for customers to buy compressors is whether they are genuine. Nobody wants to buy a fake machine after spending money. Here, we briefly introduce how to distinguish the authenticity of the Copeland compressor.
-
07/17/2020
Solutions to Copeland Compressor Insufficient Lubrication Failure Performance
Solutions to Copeland Compressor Insufficient Lubrication Failure Performance Copeland compressor If the lubrication is insufficient, the direct cause of wear is the lack of smoothness. The lack of oil will definitely lead to lack of smoothness, but the lack of oil is not necessarily caused by lack of oil.
-
07/17/2020
Five items to pay attention to when using Copeland compressors
Copeland compressors are strictly forbidden to perform pressure test under oxygen, and for nitrogen without safety valve! Improper use will cause an explosion and cause casualties. Some users have already experienced this situation. I hope that all dealers promptly remind the installation personnel and use it as a warning. They must follow the operation process.