Summary Essentials of water treatment for central air-conditioning chillers
Looking at the management of central air-conditioning throughout the country, it is found that very few are well managed, and all have problems of one kind or another to varying degrees. The main problems are described as follows:
1. Problems caused by the unreasonable design of the design department
Many central air conditioners in many units will have various problems during operation. After analysis, a considerable part of them are caused by unreasonable design or even design errors in the design department. Common unreasonable design problems are as follows:
1. In order to prevent scale, a magnetic water device is designed in the water treatment system
There are many types and names of magnetic water devices, some are called electronic water descalers, high-frequency water changers, etc. In short, they all magnetize (polarize) water molecules, and polarized water molecules have extremely strong electricity. Negative, attract calcium and magnesium ions, thereby delaying the scaling time and achieving the purpose of scale prevention. Water molecules with strong electronegativity can also degrade scale and rust. Therefore, some manufacturers say that the products have the functions of anti-scaling, anti-corrosion, descaling and rust removal. Indeed, magnetic water heaters have certain positive effects mentioned above. However, if the installation quantity and installation location of the magnetic water device are not designed properly, it will cause serious corrosion to the water system, and its negative effect is far greater than the positive effect. Cause serious harm to air conditioning equipment and water systems.
For example: For the fully imported central air conditioner of Shenzhen International Trade Building (50 storeys), the design department has designed and installed more than ten magnets in the water system, of which ten magnets are installed in the chilled water system alone. No other water treatment methods have been adopted. The equipment suffered severe corrosion after only one and a half years of operation. The water samples were tested, and the copper ions in the water were as high as 50 milligrams per liter, and the iron was as high as 200 milligrams per liter.
In order to solve the corrosion problem, when sampling from the side of the water inlet of the circulating water pump of the chilled water system, it was found that clumps of red rust gushed out with the water. There is about 8mm thick flocculent rust at the bottom of the 200ml conical flask. The corrosion of the water system is quite serious. I looked up and found that more than 10 magnets were working, and immediately turned off all the magnets of the chilled water system, and only one of the cooling water systems was left working (all magnets were turned off later). This is the source of serious corrosion in the system. It is recommended to use a series of water treatment agents for scale and corrosion prevention. Since the end of 1999, the central air-conditioning system of the building has adopted a series of water treatment chemicals to strengthen operation management. After injection, the equipment neither grows scale nor rust. Test water samples: copper content <0.02mg/L (not detectable), iron content <0.5mg/L.
Li Gong, the chief engineer of Lingdu, suggested that you don't install magnetic water heaters in the central air-conditioning system, and you should install magnetic water heaters on tea stoves and bath stoves.
2. A vertical decontamination device should be installed in the cooling water system
At present, the decontamination devices installed in the central air conditioners of chillers all over the country are all inverted Y-shaped, installed on the riser before the entrance of the air conditioning unit. This inverted Y-shaped decontamination device on the riser can only Capture construction waste in the early stage of equipment operation to prevent these waste from entering the condenser. However, this inverted Y-shaped decontamination device cannot capture fine scale and rust in daily operation, so it will cause condenser fouling, sludge and other impurities.
The correct method is to install a vertical decontamination device (same as the decontamination device in the hot water boiler system) before the water inlet of the condenser to trap various impurities in the cooling water system in the decontamination device.
3. Design a fast drain valve on the outlet side of the cooling water and chilled water of the air conditioner
At present, many units do not have quick drain valves installed at the cooling water end plates or chilled water end plates of central air conditioners, and some units also use seals to block these drain outlets. In fact, this approach is very wrong, and it is easy to cause internal accumulation of air conditioners. The accumulated impurities affect the heat exchange efficiency and also cause the condenser to be cleaned regularly every year.
The correct method is to discharge sewage from the outlet side of the condenser according to the "three-open and three-close method" for the cooling water system 2-3 times a week, and for the chilled water system to discharge sewage according to this method once a week.
4. Install a tap water meter on the make-up pipe of the cooling tower and the make-up pipe of the chilled water make-up tank.
At present, there is no tap water meter installed on the cooling water and chilled water supply pipes of a considerable part of central air conditioners, so that users do not know how much water there is in the system or how many tons of water are added per day, which brings a lot of trouble to operation and management. Because central air-conditioning water treatment generally uses chemical treatment, it must be dosed according to the amount of water supplemented and the amount of system water, so these two water meters are indispensable in design.
5. It is best not to use softened water as the central air-conditioning water supplement
Li Gong, chief engineer of Lingdu, discovered in 2002 that sodium ion exchange regeneration waste liquid caused permanent pollution to groundwater. In Guangzhou, 2 to 5 kilograms of salt are discharged underground for every ton of softened water produced. Due to the requirements of the low-pressure boiler water quality standard (now called the "industrial boiler water quality standard") GB1576, almost all industrial boilers (boilers with pressure ≤ 2.5Mpa) use softened water as boiler feed water. There are more than 9,000 boiler rooms in Guangzhou. Among them, there are more than 2,800 large-scale boiler houses, and hundreds of thousands of tons of salt are discharged underground every year, causing permanent pollution of groundwater, leading to increased risk of humans suffering from high blood pressure, heart disease, and cancer. The consequences are terrible. The United States has restricted the use of sodium ion exchangers.
As mentioned above, it can be seen that the use of softened water is very harmful, so it is recommended that the design department never use softened water as makeup water when designing central air-conditioning. One is to reduce the pollution of groundwater, and the other is to ensure the safe and reasonable operation of the central air conditioner itself. Because softened water is only scale-proof and not anti-corrosive, it is more corrosive than tap water. Using softened water as a water source will cause corrosion of the air-conditioning water system, and it will eventually require anti-corrosion. The general water treatment chemicals should be both anti-scaling and anti-corrosion. In this way, choosing softened water for hydrating is not a good way.
2. Several issues that should be paid attention to in operation control
As the saying goes, "three points for medicine, seven points for management", it can be seen that it is also very important to formulate indicators and methods for central air-conditioning operation and management. Doing a good job in the water treatment operation management of central air conditioning is nothing more than anti-scaling, anti-corrosion, sterilization, and algae killing, and to extend the service life of equipment.
1. Anti-scaling, anti-corrosion
For anti-scaling and anti-corrosion, advanced water treatment chemicals should be selected to ensure that the equipment is free of scale and corrosion.
2. Sterilization and algae killing
The refrigeration system of central air-conditioning generally runs in the hot summer, not only the cooling tower tray is prone to bacteria and algae. Therefore, most units in the south are adding fungicides and algaecides on a regular basis. At present, the commonly used bactericidal and algicides on the market are all oxidizing (and there are non-oxidizing ones), so they have corrosive effects on the iron system. Long-term addition will cause corrosion to the system. Users should pay attention when choosing a bactericidal and algicide.
Sterilization and algae killing is a passive approach. If we choose antiseptic and scale inhibitors and choose agents that can inhibit the growth of bacteria and algae, it will serve the purpose of multiple functions, so that we can avoid or use less bactericidal and algicide. The water system is free of scale, corrosion, bacteria and algae, and the entire water system is free of any impurities, saving more than 20% of electricity during operation.
3. Adjust and control the PH value of the air conditioning water system
There are both copper and iron in the air-conditioning water system, so that both metals are protected. This should control the PH value of the system water between 9 and 9.9, because the passivation zone of iron is at a pH value of 9 to 13. Iron likes alkaline medium, while copper is afraid of alkali. When the pH value reaches 10, copper begins to be corroded. Therefore, in a water system where copper and iron coexist, the pH value should be strictly controlled at 9-9.9 (preferably 9.0-9.9) ).
This also helps to inhibit the growth of bacteria and algae.
It is not difficult to do a good job in the water treatment of central air conditioning. As long as the design and installation are reasonable, the selection of advanced chemicals, and the operation control are reasonable, the water treatment of the central air conditioning can be successfully completed.
Summary Essentials of water treatment for central air-conditioning chillers
Recent related posts
-
09/10/2020
Summary Essentials of water treatment for central air-conditioning chillers
Looking at the management of central air-conditioning throughout the country, it is found that very few are well managed, and all have problems of one kind or another to varying degrees. The main problems are described as follows: 1. Problems caused by the unreasonable design of the design department
-
09/10/2020
Structural characteristics of rolling bearings imported from FAG
German FAG bearings (especially rolling bearings) are divided into two kinds of structure with cage and without cage. Among them, large-scale FAG bearings are generally required to withstand larger loads, often without a cage, but filled with rolling elements between the inner and outer raceways. And most of the small and medium rolling bearings are with cages.
-
09/10/2020
Regular maintenance and maintenance of Fusheng air compressor
1. Regular maintenance and maintenance of main components In order to enable the air compressor to operate normally and reliably and ensure the service life of the unit, a detailed maintenance plan must be formulated, manned operations, regular maintenance, and regular inspection and maintenance are required to keep the air compressor unit clean, oil-free, and dirt-free.
-
09/10/2020
Questions and Answers on Filter Technology of Compressed Air Purification System
1 Why is the most harmful of oil in the air? Answer: In some places with strict requirements, such as pneumatic control systems, a drop of oil can change the condition of the air holes. Paralyze the production line that was originally running normally and automatically.
-
09/10/2020
Prospect analysis of screw refrigeration compressor
The market potential of China's refrigeration and refrigeration industry is very high, especially the development prospects of medium and low temperature refrigeration and refrigeration equipment in the agriculture, fishery, and animal husbandry industries are very broad.
-
09/10/2020
Many Chinese valve companies are not strong, product adjustment is the key
As a fluid transport component, the valve follows the development of the national economy, especially the national coal chemical industry and equipment manufacturing industry.
-
09/10/2020
Lubrication characteristics and requirements of mobile air compressors
1. The characteristics of the mobile air compressor are: (1) The mobile air compressor should be easy to move frequently, the working conditions are changeable, and the load changes greatly. (2) Mobile air compressors are mostly heavy-duty, medium-speed or low-speed transmission, and most require frequent starting and often withstand shock loads;
-
09/10/2020
List of relevant air compressor standards
Serial number Standard code standard name Remarks
-
09/10/2020
Knowledge of air compressor oil lubrication
Knowledge of air compressor oil lubrication What is the lubrication principle of air compressor oil? The lubrication principle of air compressor oil is to reduce friction. The so-called friction means that when two relatively moving surfaces undergo relative displacement under the action of external force, there is a relative contact surface called friction surface.
-
09/10/2020
Innovative filtration technology in the automotive industry
This article focuses on some innovative filtration and separation technologies used in the automotive industry. The article focuses on the application of these technologies in the field of engine manufacturing.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
Delixi Fuse HH15A 250A 3P
HONEYWELL Butterfly Valve V8BFW16-100