The correct installation method of air-cooled chiller
I believe everyone is familiar with air-cooled chillers. According to different compressors, air-cooled chillers are divided into screw-type air-cooled chillers and scroll-type air-cooled chillers. When everyone buys a chiller, they will consider a problem chiller installation. The editor of okmarts.com will share with you the installation of air-cooled chillers.
The condenser of the air-cooled chiller is a fin type, and a heat dissipation fan is installed on the top of the unit, and the heat dissipation is directly through the fan to achieve the heat exchange effect. Relatively speaking, its installation is much simpler than water-cooled chillers, as long as the air-cooled chiller and the equipment to be cooled are connected by pipes. The specific installation procedure is as follows:
1. Before installation, choose a flat area. It is best to re-lay the cement foundation to ensure the levelness of the ground. After the air-cooled chiller is installed, there should be free space for future maintenance and ensure The ground can bear the operating weight of the chiller.
2. Different chiller models have different inlet and outlet pipe diameters. When installing, choose water pipes with matching pipe diameters and connect them correctly.
3. Regardless of any load conditions, ensure that the water flow of the air-cooled chiller is normal and stable.
4. The design and installation of all chilled water pipelines should be carried out in accordance with relevant standards, and the water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow of the unit.
5. The pipeline should have a firm support independent of the chiller to avoid stress on the components of the air-cooled chiller. In order to reduce noise and vibration, it is best to install a vibration isolator on the pipeline.
6. In order to be able to operate the air-cooled chiller safely and stably, to ensure the normal use of various components, the bad water quality can be treated to avoid various sundries or corrosive deposits and the existence of pipelines, evaporators, and condensers. The thermal effect increases the maintenance cost in the later period.

Related Info
Solutions to minor failures of chillers and methods to ensure low failure rates Specific factors affecting the cooling effect of air conditioning Talking about the purchasing skills of cross-flow closed cooling tower Teach you how to understand the data meaning of the high and low pressure meters in the chiller Technical standards and selection principles of explosion-proof chillersThe correct installation method of air-cooled chiller
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Parker Sporlan Expansion Valve 109128
Contact Us
APISTEK Fan GA81S2
US$144.19
HONEYWELL Butterfly Valve V4BFW16-80+OM-1
Contact Us
Sumitomo Gear Pump QT3223-16-16
Contact Us
Copeland Compressor 6DJNF11ME-FSD-799
Contact Us
Rockwell A-B Sensor 872C-G12N18-N3
US$84.62
Delta Fan AFB1548SH-CR00
Contact Us