The method to identify the failure of the totally enclosed refrigeration compressor is very effective!

The method to identify the failure of the totally enclosed refrigeration compressor is very effective! 1. How to identify the three binding posts on the casing of the hermetic compressor? Running end (R), starting end (S), common end (C), the resistance between RS is greater than that between SC and RC. The resistance between RS is equal to the resistance between SC plus the resistance between RC. It can be judged by the above rules. It should be noted that the resistance value of the temperature rise tester of the terminal of the three-phase compressor is equal. 2. How to judge the short circuit of compressor motor winding? Use a multimeter to select the resistance file. After zero adjustment, measure the resistance value of the compressor motor winding C-R or C-S. If the resistance value of the measured winding is less than the normal value, it can be judged that the winding is short-circuited. Three-phase compressor: ◆ The resistance value measured twice is infinite, indicating that there is a group of windings open circuit; ◆ The three tests are infinity, indicating that at least two sets of windings are broken; ◆ Among the 3 measurements, 2 times the measured resistance value is obviously smaller than the other time, indicating that there is a short circuit. 3. How to judge whether the compressor motor hits the ground? Use a multimeter for resistance. Then hold a pen tightly to the common point, another table pen tightly on the exposed metal part of the compressor process tube, or support the small piece of paint on the shell plate to measure. If the resistance value is very small, it can be judged that the winding or internal wiring touches the shell through the ground. 4. How to judge the broken circuit of compressor motor winding? Adjust the multimeter to the resistance range, connect the test leads to the terminals of any 2 windings, and measure the resistance value. If the winding value is infinite, that is, there is no conduction between the terminals of the two windings, it can be judged that the winding is open. 5. What does the compressor not check? ◆ Check whether the compressor overload, pressure switch, and overcurrent protector have tripped or damaged. ◆ Check whether the indoor temperature sensor and tube temperature controller are open or poorly connected, and whether there is a short circuit. ◆ Check whether the relay is closed, the compressor is open or short-circuited, and the compressor capacitance is broken. 6. What are the reasons why the compressor is overheated, causing it to shut down soon after starting? ◆ Insufficient or excessive refrigerant, clogged capillary components, air leakage inside the four-way valve. ◆ The compressor itself is faulty, such as short circuit, open circuit, touch the shell, etc. ◆ If the high pressure is too high, the pressure relay will act. ◆ Poor ventilation of condenser or short circuit of airflow, or the system is mixed with non-condensable gas. ◆ The ambient temperature of the outdoor unit is too high. ◆ Compressor stuck cylinder or holding shaft. 7. Performance of low compressor efficiency Generally, the discharge pressure decreases, the suction pressure increases, and the temperature of the compressor cylinder head and the suction and discharge chambers is too high. 8. Judgment of compressor's loss of working ability First test whether the suction port is inhaled, then test whether the exhaust port is exhausted, and block the exhaust port with your hand. If you feel that the pressure is not very large, or even there is no exhaust, you can think that the compressor has lost its ability to work. 9. Why is the compressor motor current too large? The compressor turns short between turns, but it does not reach the level of blown fuse. The "secondary friction" of the compressor destroys the smoothness of the friction surface, causing the power and current of the compressor to increase, but it has not yet reached the "shaft holding" or "clamping cylinder", which prevents the compressor from rotating. Use a multimeter to check the insulation resistance of the compressor to ground. Normally, it should be above 2MΩ. If it becomes smaller or close to zero, it means that it has been short-circuited. If the insulation resistance to ground is normal, check the resistance value of the starting and running windings. If there is a short circuit between turns, the operating current increases. 10. What are the reasons for the difficulty of starting the three-phase compressor motor? ◆ The power supply voltage is too low and the compressor motor winding is short-circuited. 11. How to eliminate the faults that the three-phase compressor motor slows down during operation, one-phase fuse blows, and one-phase current increases? ◆ It is often caused by a collision of the compressor motor winding and the ground connection. After removing the ground wire, you can use a test pencil to test whether the case is live. If the casing is electrified, rewind the compressor motor winding or replace the compressor. 12. How to exclude the "sing" sound of the three-phase compressor motor during operation? ◆ The three-phase compressor motor emits "speak" during operation, which is caused by the severe imbalance of the three phases. One phase power supply lacks the phase, and the three phases can be restored. 13. How to exclude the reverse rotation of the three-phase compressor motor? ◆ It is caused by wiring error, and it is enough to exchange two wires in three phases arbitrarily. 14. Compressor replacement sequence and points of attention ◆ R22 is a non-combustible gas, but when it comes into direct contact with a high-temperature flame, toxic gas will be generated. Therefore, before the welding operation, release the refrigerant in the refrigeration system. ◆ R32 is a flammable and explosive refrigerant. We have also emphasized the characteristics of this refrigerant many times. Any R32 refrigeration equipment involved in the maintenance of the refrigeration system needs to be replaced, and it must be evacuated before operation! Be careful not to introduce fire sources! ◆ R410A is low-toxic, non-combustible and non-explosive. If you replace the compressor, you must use the R410A compressor. You must not use the R22 compressor to install it. When replacing the valve, there is a special mark on the R410A valve body. 15. What are the types of air conditioner compressor overload protectors? ◆ External overload protector; embedded overload protector. 16. What are the protection of the compressor? ◆ Overload protector: mainly used for overcurrent and overheat protection of compressor motor. ◆ Internal protector: It mainly protects the compressor motor from overcurrent. ◆ Thermal relay: mainly used for line overcurrent protection of three-phase compressor motor. ◆ Reverse phase preventer: mainly used for three-phase rotary compressors to prevent the reverse direction of compressor rotation or lack of phase energy. 17. What are the common causes of overload protectors? ◆ The power supply voltage is too low and the symmetry of the three-phase voltage is poor. ◆ Compressor motor runs at low speed for extended time. ◆ Compressor motor running with low voltage and long-term load. ◆ The cooling medium path of the compressor motor is blocked. ◆ The ambient temperature is too high. 18. What is the liquid blow of the compressor? ◆ The refrigerant does not completely evaporate in the evaporator, causing the refrigerant to be sucked back by the compressor in a wet vapor or liquid state, causing a liquid shock of the compressor. ◆ The liquid impact will cause the valve disc, valve plate and piston to be damaged and damaged. In severe cases, the connecting rod may also be deformed, and even the compressor may be damaged.

Recent related posts

Customers frequently viewed

Submitted Successfully
Submission Failed