Use and maintenance of central air-conditioning chillers
At present, central air-conditioning refrigerators are widely used, especially in shopping malls and other places with a large number of people. What are the cooling principles, system classification and maintenance methods of central air-conditioning refrigerators? Come and find out with the editor of okmarts.com!
The use of central air-conditioning chillers simplifies the procedures for large-scale enterprises to manage and control systems. Generally, large-scale enterprises will centralize the operating systems of each link for management. This is the current development trend of the central operating system of large enterprises, and the central air-conditioning chiller is different from the single air conditioner used in the home. The central air-conditioning chiller has higher requirements on the scope of refrigeration and maintenance.
1. The refrigeration principle of central air-conditioning refrigerator
The cooling principle of central air-conditioning chiller is based on the principle that when the liquid evaporates, the surrounding heat is obtained. Under normal air pressure, water must reach 100 degrees Celsius to evaporate. However, in a vacuum environment, water can boil and evaporate without reaching 100 degrees Celsius. If it is in a closed environment with a low pressure of 6mmHg, the water to find the tissue needs to reach 4 degrees Celsius to boil and evaporate.
The lithium bromide refrigerators currently used by most companies use this principle for refrigeration. Lithium bromide is a substance with very strong water absorption capacity. This lithium bromide refrigerator uses water as a refrigerant and lithium bromide as an absorbent. Lithium bromide is a white crystal of salt, which is very easy to fuse with water, has strong stability and will not deteriorate. The key is that it is a non-toxic chemical substance and will not be harmful in use.
Lithium bromide absorption refrigerator is mainly composed of generator, condenser, evaporator, absorber, heat exchanger, circulating pump and so on. During the operation of the lithium bromide absorption refrigerator, after the lithium bromide aqueous solution in the generator is heated by the heating medium water, the water in the solution continuously volatilizes; as the water volatilizes, the concentration of the lithium bromide aqueous solution continues to increase and enters the absorber; water The steam enters the condenser, and when it encounters the cooling water of the condenser, the temperature drops and gradually condenses. It becomes high-pressure and low-temperature liquid water; when the liquid water in the condenser enters the evaporator through the throttle valve, it rapidly expands and evaporates, and absorbs a large amount of heat from the refrigerant water during the evaporation process, thereby achieving the purpose of cooling and cooling.
2. System classification of central air-conditioning refrigerators
water-cooled cold water (heat pump) type air conditioners are divided into piston type, screw type, centrifugal type, scroll type, direct combustion lithium bromide absorption type and other forms. Three types of centrifugal type, screw type and direct-fired type are commonly used. Screw-type and centrifugal-type water chillers are commonly used in various hotels and shopping malls. They are a common form of traditional Dalian central air conditioning. It is generally in the form of single cooling.
Direct-fired chillers are mainly used in areas where electricity is scarce or gas and fuel prices are low. At the same time, it can provide sanitary hot water and heating water. In addition, there are some forms of heat recovery air conditioning, which are widely used in hotels, saunas, hospitals and other places that require hot water for a long time. This form of heat recovery in summer is generally 15% of the cooling capacity, and hot water can be obtained for free, which can basically meet the hot water required by the hotel, and generally only requires a one-year investment payback period. However, in winter and transitional seasons, when the amount of air conditioner is small, it cannot be used. There are also water (ground) source heat pumps, which are more suitable for areas with abundant groundwater resources or near lakes and seawater. The water source heat pump is 10%-20% more energy-saving than traditional air conditioners. It can simultaneously meet the needs of heating in winter and cooling in summer. However, it cannot be used if the temperature in winter is lower than 0℃.
According to the compressor, it can be divided into scroll type, piston type, screw type, etc. Commonly used are screw type and scroll type. Parts of large buildings or small comprehensive buildings use this form more often. The comprehensive energy efficiency ratio of both cooling and heating is about 3.0. Other forms include: total heat recovery, partial heat recovery, and air-cooled and hot water units with partial heat recovery. Saunas, hotels, hospitals and other places that require hot water for a long time use this form more.
According to the classification of compressors, it can be divided into scroll type, piston type and other types, and scroll type is often used. The main form is: water-cooled cabinet machine. Due to the low cost and operating cost of this form, the general factory uses this form more. But its noise is relatively large, if it is used in commercial projects, it is necessary to install noise-absorbing facilities. There is also a water ring heat pump, which is composed of small units with a lot of sweat, and is installed in the equipment room or on the ceiling. This decentralized management saves energy. However, because the compressor is installed indoors, the noise is relatively large, which affects people's normal work and life. In addition, the decentralized units have increased maintenance work.
This form generally uses scroll compressors. The main form is a split machine. Other forms include: variable frequency Dalian central air conditioning system, variable frequency unit air conditioner, unit unit air conditioner unit, special air cooler for cold storage, three-in-one heat pump system, freezer, etc. The advantages of the variable frequency Dalian central air-conditioning system are its flexible location, easy control and billing, and no restrictions on the use time. In some cases, the use and operation costs are very low. But there are also shortcomings. Its cost is relatively high, and it also has to place the camera outdoors, which affects the layout of the building to a certain extent. The three-in-one heat pump system has the functions of dehumidification and heating, and is usually used in the design of swimming pools. And the overall efficiency of this system is relatively high, the hotel's constant temperature swimming pool, sauna baths, etc. will adopt this system form.
3. Common problems and maintenance methods in the use of central air conditioning refrigerators
Central air-conditioning design, noise reduction measures and installation will affect the noise level of Dalian central air-conditioning chiller. And during operation, if the impeller of the fan collides or the bearing is damaged, it will affect the excessive noise. Too much operating noise will affect people's normal life and cause economic losses to users. Air-conditioning noise mainly includes pneumatic, mechanical and electromagnetic noise. Pay attention to the craftsmanship during the installation process, check the airflow of the flyport, adjust the valve, and improve the noise reduction measures to reduce the noise of the Dalian central air-conditioning refrigerator.
The water system clogs the normal operation of the British gas refrigerator system. The main reason for the blockage of the water system is that other substances enter the pipeline or the pipeline at the water inlet is aging and cracked. If the cooling effect of the air conditioner deteriorates, you can check whether it is the cause of the blockage of the central air conditioning water system in Dalian. In the case of Zezhong, you only need to open the water filter of the water supply pipe to check and clear the blockage.
The slow cooling is because the air supply volume of the air conditioning chiller is less than the design value, the number of air changes is small, the system with secondary air return, the secondary return air volume is too large, the Dalian central air conditioning system has many rooms, and the air volume is unevenly distributed. Just check whether the fan model meets the design requirements, whether the impeller steering is correct, whether the belt is loose, open the large air supply valve, eliminate the factor of insufficient air volume, and reduce the secondary return air volume, and adjust the air volume distribution of each room.

Related Info
Three key points of cold storage planning and construction Three maintenance and inspection methods for air-conditioning refrigeration compressors Tips to avoid damage to the chiller Troubleshooting of Air Source Heat Pump Unit Understand the knowledge of quick-freezing cold storage to solve all the incurable diseases of quick-freezing cold storageUse and maintenance of central air-conditioning chillers
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
TSUBAKI Industrial Chain RF160-USN-1-RP
Contact Us
WALRUS Water Pump TQ200
US$912.50
Inovance Servo Drive IS650NT032IUY-B
Contact Us
Schneider Contactor LC1D096F7C
US$87.69
BrightKing Fuse BK60-135-DZ
US$0.19
CHELIC Air Cylinder SDXD32*125
Contact Us
Schaeffler INA Bearing RTUE100-XL
Contact Us
Suntronix Fan SHE60180
US$75.00