What requirements does the system need to meet after the air compressor frequency conversion transformation
The application optimization analysis of the frequency conversion energy-saving transformation of the frequency conversion air compressor, the energy-saving transformation design requires the problems existing in the original working conditions and the production process requirements. After the air compressor frequency conversion transformation, the system should meet the following requirements:
1. According to the industrial control requirements of the air compressor, the system should ensure that the motor has a constant torque running characteristic.
2. The motor frequency conversion operation state keeps the outlet pressure of the gas storage tank stable, and the pressure fluctuation range cannot exceed ±0.2bar.
3. The system should have two sets of control loops: variable frequency and industrial frequency.
4. In order to prevent non-sine waves from interfering with the air compressor controller, effective measures to suppress electromagnetic interference should be provided at the output of the inverter.
5. In the case of low electrical consumption, when the inverter is running at low frequency, ensure that the temperature of the motor winding and the noise of the motor do not exceed the allowable range.
6. Considering the system's future expansion, the inverter meets the requirements of future industrial control expansion.
7. The input reactor is added to the upper end of the inverter to effectively restrain the inverter's interference to the power grid.

Related Info
What environment will affect the operation of the air compressor What equipment should a typical compressed air system include What is the difference between an air pump and an air compressor What is the main purpose of the inverter Which projects are generally used for What material is used for compressed air pipesWhat requirements does the system need to meet after the air compressor frequency conversion transformation
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
OSHON Vane Pump VE1-30F-A4
Contact Us
Bristol Compressor H20C373DBXR
Contact Us
Honeywell Controller Module RM7800L1053
Contact Us
TIMKEN Bearing 6306
US$10.38
TRIAD Transformer TCT3-03E07AE
US$29.62
Eaton Moeller Circuit Breaker PKZM4-63
US$239.71
CKD Air Cylinder FCD-50-25-N
Contact Us
Copeland Compressor 6MU1-400-EWK-D
Contact Us
Suntronix Fan SHE50250
US$75.00