Repeatability: ±2% FS
Turndown Ratio: 50:1
Response Time:
FLR-1600A: 20 ms
FLV-4600A: 100 ms
Input Control Signal
(FLV-4600A Units):
0 to 5 Vdc and RS232
Output Signal: 0 to 5 Vdc, RS232
Optional Input/Outputs:
4 to 20 mA, 0 to 10 Vdc
Operating Temperature:
10 to 50°C (50 to 122°F)
Zero Shift: 0.02%/ATM FS/°C
Span Shift: 0.02%/ATM FS/°C
Excess Flow Rate:
Approx 28% overage
Maximum Pressure:
Meters: 200 psig
Controllers: 150 psig
Minimum Pressure Drop: 0.4 psid
Supply Current (Typical):
FLR-1600A: 30 mA
FLV-4600A: 250 mA
Supply Voltage:
FLR-1600A: 7 to 30 Vdc, 0.035 A
FLV-4600A: 12 to 30 Vdc, 0.250 A
Note: 15 Vdc minimum for 4 to 20 mA
output option.
Electrical Connections:
8-pin circular mini DIN
Omega Flowmeter FLR-1605A-I
There is no price at present, you can Request a Quote
People who bought this item also viewed
YOKOGAWA Flowmeter AXFC-4-L015/CH
KES Level Meter CLG-1-S1-0K-100-70-ESL
HACH Turbidity Meter TSS Portable
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
STEIN Welding Wire MEGAFIL A 867 M
GOLDENBRIDGE Welding Wire JQ?TG316L
SICK Encoder SKM36-HVV0-K02
Recent related posts
-
12/21/2022
Classifications and Features of Optical Fiber Amplifiers
An optical fiber amplifier, abbreviated as OFA, refers to a new type of all-optical amplifier used in optical fiber communication lines to achieve signal amplification.
-
09/14/2020
Large oil consumption of the unit or high oil content of compressed air
The amount of lubricating oil is too much. The correct position should be observed when the unit is loaded. At this time, the oil level should not be higher than half;
-
06/24/2020
Why the air conditioner does not cool
The cooling load is overloaded or the space is too large, the number of air conditioners is not correct; improper installation will cause poor air circulation, resulting in poor cooling effect; when the freon in the air conditioner is insufficient, it will cause the cooling effect of the air conditioner to deteriorate; the air conditioner is not on time Do cleaning and maintenance, etc.
-
11/24/2022
Classification of Flame Detectors
Burning generates smoke and releases heat, thanks to which, smoke detectors are invented to protect the people and properties.
-
09/15/2022
Hydraulic Piston Motor: Types, Working Principle and Pros and Cons (1)
A <strong>hydraulic piston motor</strong> is a type of hydraulic motor. How does a hydraulic piston pump work?
-
08/18/2020
Reasons for the high low pressure value of the chiller
In the application of industrial refrigeration, the chiller is used in conjunction with production and processing equipment, so it runs for a long time. If the customer lacks professional maintenance and routine equipment maintenance for the chiller in daily life
-
12/21/2023
AC Fan Won't Turn off (Troubleshooting Guide)
The air conditioning system can be a true lifesaver during sweltering summers and chilling winters, providing comfort and respite from extreme temperatures.
-
08/14/2020
Four Steps to Refrigeration Compressor Maintenance
Summer is coming, and the long-standing air conditioner will come in handy again! In recent years, consumers have become more and more experienced in the use of air conditioners,
-
06/22/2020
Why is the air conditioner not cooling
Why is the air conditioner not cooling There are many factors for not cooling, for example: the selected air conditioner does not match the area of the room; improper installation of the air conditioner will cause the air circulation of the air conditioner to be unsmooth; when the indoor temperature is relatively high, the air conditioner cannot be cooled when turned on; It has been aging, or the service life has expired; the air conditioner has not been cleaned for a long time, and the filter surface is covered with dust; and the freon of the air conditioner has been seriously lacking. <img src="{{media url="magefan_blog/Why_is_the_air_conditioner_not_cooling.jpg"}}" alt="" />
-
07/17/2020
Reasonably adjust the cold storage evaporator and defrost in time
Reasonably adjust the cold storage evaporator and defrost in time Generally speaking, every increase in the cold storage evaporation temperature can save energy Therefore, under the premise of satisfying the low refrigeration process of the product, the evaporation temperature can be increased as much as possible by adjusting the amount of liquid supplied. The thermal resistance of the frost layer is generally much larger than the thermal resistance of the steel pipe.