Current Rating (Amps):5A(AC),3A(DC)
Voltage Rating - AC:125 V
Voltage Rating - DC:30 V
Omron Switch D4A-2918N
People who bought this item also viewed
Omron Switch D4SL-N4HDG-D
Omron Switch V-16-1A4
Omron Switch D4B-2A71N
DANFOSS Switch MBS4510
DANFOSS Switch AKS38
PILZ Switch PSEN sl-0.5p 1.1 1switch
SHAKO Air Cylinder JCDA40B45-H
SUNX Sensor EX-11SB
Siemens Circuit Breaker 5SY4108-5
Siemens Contactor 3RT2017-2BB44-3MA0
KOSMEK Overload Pump PH1051-SG
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch FS 2896E230-F
Copeland Compressor D4DF5-100X-AWM/D
Recent related posts
-
08/23/2022
Ways to Increase Stepper Motor Torque and Select Stepper Motor
Reduce the number of turns to reduce inductance L: select the motor with small inductance L from the standard products of the motor manufacturers, the rated current will increase.
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
03/04/2021
What is servo motor brake
Servo motor brake, also known as holding brake, is a component of power release. Generally, the servo motor with brake is integrated with the motor. Generally, DC24 V power supply is used. It is mainly used to lock the rotor shaft of servo motor after power off.
-
06/13/2020
Embraco hosts flammables webinar
BRAZIL: Compressor manufacturer Embraco will host two free educational webinars in June, one covering refrigeration fundamentals, the other on the use of flammable “natural” refrigerants in commercial refrigeration.
-
03/21/2022
How to Replace a Circuit Breaker?
A circuit breaker is a switching device connected to an electrical circuit that interrupts the current flow when it is excessive.
-
01/03/2021
Danfoss Sight glass
Check the stamp and the indicator color It pays to stay clear of counterfeited products. The dangers of choosing fake rather than genuine Danfoss products are significant and likely to jeopardise your reputation in the market. Go genuine. Our sigh 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֤ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
08/17/2023
Exploring the Pros and Cons of Portable Heat Pumps for Efficient Home Heating and Cooling
Portable heat pumps are becoming an increasingly popular option for homeowners who want to efficiently heat and cool their homes without the need for ductwork.
-
08/05/2020
What are the common faults of the cut-off foot of the chiller and the adjustment cabinet
1. The valve body of the valve of the chiller is mostly steel castings. Casting blisters may be formed during the production process, causing the valve to leak refrigerant during use.
-
10/23/2023
Air Conditioner Line Frozen: Causes, Troubleshooting and Prevention Methods
When the air conditioner line freezes, it can be a frustrating experience for homeowners. Not only does it disrupt the cooling process, but it also indicates an underlying issue that needs to be addressed.
-
09/14/2020
Selection guide for air compressor
Selection of working pressure (exhaust pressure): When the user is preparing to purchase an air compressor, first determine the working pressure required by the air end, add a margin of 1-2 bar, and then select the pressure of the air compressor (the margin is considered from the air compressor The pressure loss from the installation site to the actual gas end pipeline distance, according to the length of the distance between 1-2 bar, appropriately consider the pressure margin)