Current Rating (Amps):10A (DC)
Voltage Rating - AC:125 V Voltage Rating - DC: 30 V
Omron Switch DZ-10GW22-1A
People who bought this item also viewed
Omron Switch D4B-2A71N
Omron Switch D4SL-N4HDG-D
Omron Switch V-16-1A4
CHANTO Switch TG-C73
PILZ Switch 570500
CKD Air Cylinder SCA2-00-100B-150/Z
Balluff Sensor BES028L
Fuji Circuit Breaker EA53B-3P20A
ALBRIGHT Contactor SW82-370P
SANDSUN Overload Pump VS10AA-760
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Contactor 3RT2516-2AP60
Keyence Sensor PZ-G42EN
REER Light Curtain EOS2 903 A
Rosenberg FAN DKHR560-4KW.174.7KF
Dwyer Transmitter 644-B-C-05-P
Rexroth Piston Pump A2FO63-61R-VBB05
Recent related posts
-
01/15/2021
dafoss low-pressure
Differential setting on low pressure control too low. Solution: Area Low pressure System Part Compressor Symptom Compressor running time too short Potential Cause Differential setting on low pressure contol too low. Solution Increase the differ 器2 䀀
-
02/23/2021
The reason why the air conditioner is not cooling
Occasionally encounter the problem that the air conditioner does not cool in life. Don't worry at this time. The reason for the air conditioner not cooling is not very complicated. After understanding the reason for the air conditioner not cooling, you can solve the problem by taking the right medicine.
-
07/20/2020
Analysis of circuit diagrams of two compressors' phase failure protection
Analysis of circuit diagrams of two compressors' phase failure protection Air compressor phase failure protection circuit Protection circuit diagram Air compressor phase failure protection circuit
-
06/14/2020
How important is the installation environment of the refrigeration unit It is enough to do these 4 points!
How important is the installation environment of the refrigeration unit It is enough to do these 4 points! The refrigeration equipment (compressor unit) is installed in the machine room, and the surrounding environment should be maintained:
-
09/14/2022
Hydraulic Piston Motor: Types, Working Principle and Pros and Cons (1)
A <strong>hydraulic piston motor</strong> is a type of hydraulic motor. How does a hydraulic piston pump work?
-
12/04/2023
Notebook Cooling: Function Analysis of Thermal Grease, Heat Pipe and Cooling Fins
In the cooling module of the notebook, the three most critical elements are the heat pipe, the cooling fan and the cooling fins, and there are also elements used to improve the contact area and heat transfer efficiency between them.
-
06/29/2020
What is the cause of compressor pipeline vibration
-
08/07/2020
Working principle of frequency converter
Inverters can be divided into voltage type and current type inverters.<br></br> Voltage type is an inverter that converts the DC of a voltage source to AC. The filtering of the DC loop is a current type that converts the DC of the current source to A
-
09/06/2020
Application of Frequency Conversion in Oilfield Development and Energy Saving
The application of frequency conversion energy saving in the crude oil extraction industry is mainly manifested in various pumps. In order to ensure the reliability of production, all kinds of production machinery have a certain margin when they are designed and equipped with power drives.
-
08/15/2020
The main cause of cold storage fire is cold storage installation or cold storage construction
In recent years, we have seen a lot of news about cold storage fires. Once a cold storage causes a fire, it will not only cause economic losses to us, but also may cause safety problems.