Panasonic Air Conditioner KFR-36GW-BpSFL1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
DAYTON Speed Reducer 4Z385
Baumer Sensor UNDK 20U6903/S35A
Keyence PLC KV-N8EXR
Recent related posts
-
07/01/2020
Taikang Compressor Introduction of positive displacement compressor
Taikang Compressor Introduction of positive displacement compressor The compressor is a driven fluid machine that raises low-pressure gas to high-pressure gas. It is the heart of the refrigeration system. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe and drives the piston to compress it through the operation of the motor. , Discharges high-temperature and high-pressure refrigerant gas into the exhaust pipe to provide power for the refrigeration cycle, thereby realizing the refrigeration cycle of compression → condensation (heat release) → expansion → evaporation (heat absorption).
-
06/25/2020
[Information] The functions and characteristics of commonly used compressed air flow meters
[Information] The functions and characteristics of commonly used compressed air flow meters 1. The role of compressed air flowmeter Compressed air is an important secondary energy source for enterprises and institutions, most of which is converted from electrical or thermal energy by compressors.
-
01/03/2023
Parameters of the Solenoid Coil
The solenoid coil is tightly wrapped up on a core to form a solenoid. The main parameter of the solenoid coil is the size of the inductance.
-
08/20/2020
Emergency shutdown treatment for sudden cooling water cut
During the operation of refrigeration equipment, accidents of sudden cooling water interruption sometimes occur. The cause of this accident is generally the failure of the cooling water pump.
-
08/11/2020
Principles and characteristics of heat recovery series air conditioning units
With the growth of China’s economic power and the continuous improvement of people’s material and cultural living standards; the rapid development of high-rise buildings,
-
07/05/2020
Hitachi 5P cold storage compressor
Hitachi 5P cold storage compressor Practical knowledge-advantages and disadvantages of the four compressors There are many kinds of compressors, commonly used are scroll compressors, piston compressors, centrifugal compressors, screw compressors, etc.
-
04/24/2024
FANUC Servo Amplifier Alarm Codes and Solutions (SV460~SV494)
FANUC Servo Amplifier Alarm Codes and Troubleshooting Methods
-
12/24/2023
Why is Your Outside AC Unit Fan Not Running but Inside is? Troubleshooting and Solutions
As the sweltering summer heat bears down upon us, air conditioning becomes a vital necessity for maintaining comfort and sanity.
-
09/05/2020
Common sense of micro vacuum pump
The so-called vacuum refers to a gas state with a pressure lower than 101325Pa in a given space. In the vacuum state, the lean degree of gas is usually expressed by the pressure value of the gas. Obviously, the smaller the pressure value, the thinner the gas. There are various vacuum pumps in the industry. There are prescribed test methods for the performance of various pumps. The main parameters are:
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.